NB boiler seriesHandling Company
Nippon Kikan Co., Ltd.Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Product weight kg | Fuel | Regulations Installation notification | Regulations Completion inspection | Laws and regulations Structural standards | Regulations Performance inspection | Legislation Air Pollution Control Act | Laws and regulations Operator qualifications | Body length | Exhaust port height | Outer diameter of exhaust port | Exhaust port location | Performance Operating water volume L | Performance Equivalent evaporation amount (kg/h) | Performance Fuel consumption L/h | Performance Calorific value kcal/h | Performance Full water volume L | Performance Maximum working pressure MPa | Performance Actual evaporation kg/h | Performance Heat transfer area m^2 | Performance Boiler efficiency % | Pedestal width | Cradle length | Cradle position | Overall height | Full width | Burner height | Burner electric motor 50Hz/60Hz | Body outer diameter | Burner length |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NB650 |
Available upon quote |
2,200 |
Recycled oil |
Establishment notification (submitted to Labor Standards Inspection Office) |
- |
Small boiler (approved) |
- | - |
Those who have taken "special education" provided by the employer or above |
1,635 |
1,750 |
Φ255 |
255 |
120 |
650 |
40.8 |
350,400 |
190 |
0.981 |
545 |
7.38 |
98 |
1,040 |
1,450 |
105 |
2,280 |
1,380 |
950 |
1.5 |
1,180 |
770 |
![]() |
NB800 |
Available upon quote |
2,200 |
Recycled oil |
Establishment notification (submitted to Labor Standards Inspection Office) |
- |
Small boiler (approved) |
- | - |
Those who have taken "special education" provided by the employer or above |
1,635 |
1,750 |
Φ255 |
255 |
120 |
792 |
49.8 |
426,900 |
190 |
0.981 |
664 |
7.38 |
98 |
1,040 |
1,450 |
105 |
2,280 |
1,380 |
950 |
1.5 |
1,180 |
770 |
![]() |
NB1000 |
Available upon quote |
2,400 |
Recycled oil |
Establishment notification (submitted to Labor Standards Inspection Office) |
- |
Small boiler (approved) |
- |
Submit a smoke generating facility notification form (at the time of installation) |
Those who have taken "special education" provided by the employer or above |
2,010 |
1,750 |
Φ350 |
325 |
150 |
1,000 |
62.8 |
539,000 |
250 |
0.981 |
838 |
9.87 |
98 |
1,040 |
1,840 |
105 |
2,280 |
1,380 |
950 |
1.5 |
1,180 |
766 |
![]() |
NB1500 |
Available upon quote |
2,450 |
Recycled oil |
Establishment notification (submitted to Labor Standards Inspection Office) |
- |
Small boiler (approved) |
- |
Submit a smoke generating facility notification form (at the time of installation) |
Those who have taken "special education" provided by the employer or above |
2,010 |
1,750 |
Φ350 |
325 |
150 |
1,500 |
93.3 |
808,500 |
250 |
0.981 |
1,257 |
9.87 |
99 |
1,040 |
1,840 |
105 |
2,280 |
1,380 |
950 |
2.2 |
1,180 |
853 |
![]() |
NB2000 |
Available upon quote |
2,450 |
Recycled oil |
Establishment notification (submitted to Labor Standards Inspection Office) |
- |
Small boiler (approved) |
- |
Submit a smoke generating facility notification form (at the time of installation) |
Those who have taken "special education" provided by the employer or above |
2,010 |
1,750 |
Φ400 |
325 |
150 |
2,000 |
124.4 |
1,078,000 |
250 |
0.981 |
1,676 |
9.87 |
99 |
1,040 |
1,840 |
105 |
2,280 |
1,380 |
950 |
3.7 |
1,180 |
853 |
![]() |
NB2400 |
Available upon quote |
4,300 |
Recycled oil |
Establishment notification (submitted to Labor Standards Inspection Office) |
Inspection experiment by the Director of Labor Standards Inspection (at the time of installation) |
Ministry of Health, Labor and Welfare Notification “Structural Standards for Boilers and Pressure Vessels” |
Inspection experiment by the Director of Labor Standards Inspection (once/year) |
Submit smoke generating facility notification form (at the time of installation)/Measurement (once/year) |
Persons who have completed boiler handling skills training |
2,845 |
2,330 |
Φ440 |
365 |
410 |
2,400 |
149.3 |
1,293,600 |
510 |
0.981 |
2,011 |
27.99 |
99 |
1,000 |
2,500 |
230 |
3,160 |
2,336 |
1,214 |
3.7 |
- | - |
![]() |
NB3200 |
Available upon quote |
4,350 |
Recycled oil |
Establishment notification (submitted to Labor Standards Inspection Office) |
Inspection experiment by the Director of Labor Standards Inspection (at the time of installation) |
Ministry of Health, Labor and Welfare Notification “Structural Standards for Boilers and Pressure Vessels” |
Inspection experiment by the Director of Labor Standards Inspection (once/year) |
Submit smoke generating facility notification form (at the time of installation)/Measurement (once/year) |
Persons who have completed boiler handling skills training |
2,845 |
2,330 |
Φ440 |
365 |
410 |
3,200 |
199 |
1,724,800 |
510 |
0.981 |
2,681 |
27.99 |
99 |
1,000 |
2,500 |
230 |
3,160 |
2,336 |
1,214 |
7 |
- | - |
![]() |
NB4000 |
Available upon quote |
4,450 |
Recycled oil |
Establishment notification (submitted to Labor Standards Inspection Office) |
Inspection experiment by the Director of Labor Standards Inspection (at the time of installation) |
Ministry of Health, Labor and Welfare Notification “Structural Standards for Boilers and Pressure Vessels” |
Inspection experiment by the Director of Labor Standards Inspection (once/year) |
Submit smoke generating facility notification form (at the time of installation)/Measurement (once/year) |
Persons who have completed boiler handling skills training |
2,845 |
2,330 |
Φ440 |
365 |
420 |
4,000 |
248.8 |
2,156,000 |
520 |
0.981 |
3,351 |
29.85 |
99 |
1,000 |
2,500 |
230 |
3,160 |
2,336 |
1,214 |
9 |
- | - |
![]() |
NB5000 |
Available upon quote |
4,550 |
Recycled oil |
Establishment notification (submitted to Labor Standards Inspection Office) |
Inspection experiment by the Director of Labor Standards Inspection (at the time of installation) |
Ministry of Health, Labor and Welfare Notification “Structural Standards for Boilers and Pressure Vessels” |
Inspection experiment by the Director of Labor Standards Inspection (once/year) |
Submit smoke generating facility notification form (at the time of installation)/Measurement (once/year) |
Persons who have completed boiler handling skills training |
2,845 |
2,330 |
Φ440 |
365 |
420 |
5,000 |
311 |
2,695,000 |
520 |
0.981 |
4,189 |
29.85 |
99 |
1,000 |
2,500 |
230 |
3,160 |
2,336 |
1,214 |
12.5 |
- | - |
Click on the part number for more information about each product