All Categories

History

Wireless gas detection department KD-100 series-KD-100A
Wireless gas detection department KD-100 series-New Cosmos Electric

Wireless gas detection department KD-100 series
New Cosmos Electric

New Cosmos Electric's Response Status

Response Rate

100.0%

Response Time

28.8hours

Relatively Fast Response


About This Product

It is a wireless gas detector that adopts the internationally standardized industrial radio standard "ISA100.11a". Product lineup ◆ External power supply type KD-100 series: Stable power supply is possible In addition, the KD-101 series does not require power wiring, reducing initial costs. Equipped with 4-20mA output and contact output in addition to wireless ◆ Battery power supply type KD-101 series: Complete cableless, wireless gas concentration signal, etc., no signal wiring is required The KD-101 series has a contact output, and the system is redundant by multiple output. Product features ・ Easy maintenance on site with one magnet stick ・ Because the sensor is a unit type, it is easy to replace ・ Can be used as a wireless converter in the conventional gas detection unit (KD-100m) ・ Wireless module extension is possible (optional) ・ Waterproof and dustproof structure (protection grade IP65)

  • Product

    Wireless gas detection department KD-100 series

Share this product


420+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Wireless gas detection department KD-100 series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Detection principle Gas to be detected Detection method Gas concentration display Explosion -proof structure Protection grade Compatible cable Used temperature humidity range power supply power consumption External dimensions mass
Wireless gas detection department KD-100 series-Part Number-KD-100A

KD-100A

Available upon quote

Heat ray type semiconductor

Flammable gas/toxic gas

Diffusion ceremony

LCD: Digital 4 -digit display

Body: EXD [IA] IICT5

IP65

Cable outer diameter: φ9-15 Power Sources: CVV-S1.25 ~ 5.5㎟ Others: CVV-S1.25-2.0㎟

Temperature: -10 ~+50 ℃ Humidity: 10-90%RH (0 to 50 ° C)

DC24V (DC18V -35V)

Up to 3.5W

H338 × W146 × D160mm (excluding cable ground part)

Approximately 3.7kg

Wireless gas detection department KD-100 series-Part Number-KD-100B

KD-100B

Available upon quote

Contact burning ceremony

Flammable gas/toxic gas

Diffusion ceremony

LCD: Digital 4 -digit display

Body: EXD [IA] IICT5

IP65

Cable outer diameter: φ9-15 Power Sources: CVV-S1.25 ~ 5.5㎟ Others: CVV-S1.25-2.0㎟

Temperature: -20 ~+50 ℃ Humidity: 10-90%RH (0 to 50 ° C)

DC24V (DC18V -35V)

Up to 3.5W

H338 × W146 × D160mm (excluding cable ground part)

Approximately 3.7kg

Wireless gas detection department KD-100 series-Part Number-KD-100m

KD-100m

Available upon quote

No sensor (4-20ma signal conversion)

-

Diffusion ceremony

LCD: Digital 4 -digit display

Body: EXD [IA] IICT5

IP65

Cable outer diameter: φ9-15 Power Sources: CVV-S1.25 ~ 5.5㎟ Others: CVV-S1.25-2.0㎟

Temperature: -20 ~+50 ℃ Humidity: 10-90%RH (0 to 50 ° C)

DC24V (DC18V -35V)

Up to 2.5W

H342 x W146 x D160mm (excluding cable ground part)

Approximately 3.3kg

Wireless gas detection department KD-100 series-Part Number-KD-100D

KD-100D

Available upon quote

Fixed potential plateau

Carbon monoxide/hydrogen sulfide

Diffusion ceremony

LCD: Digital 4 -digit display

EXDB [IAGA] IICT5GB

IP65

Cable outer diameter: φ9-15

Temperature: -10 ~ + 40 ℃ Humidity: 30-85%RH (0 to 40 ° C)

DC24V (DC18V -35V) Up to 0.3A

Up to 2.3W

H338 × W146 × D160mm (excluding cable ground part)

Approximately 3.7kg

Wireless gas detection department KD-100 series-Part Number-KD-100O

KD-100O

Available upon quote

Galvani battery type

oxygen

Diffusion ceremony

LCD: Digital 4 -digit display

EXDB [IAGA] IICT5GB

IP65

Cable outer diameter: φ9-15

Temperature: -10 ~ + 40 ℃ Humidity: 30-85%RH (0 to 40 ° C)

DC24V (DC18V -35V) Up to 0.3A

Up to 2.3W

H338 × W146 × D160mm (excluding cable ground part)

Approximately 3.7kg

Wireless gas detection department KD-100 series-Part Number-KD-100R

KD-100R

Available upon quote

Non -dispersed infrared light

Methane/Propane

Diffusion ceremony

LCD: Digital 4 -digit display

EXDB [IAGA] IICT5GB

IP65

Cable outer diameter: φ9-15

Temperature: -20 ~ + 50 ℃ Humidity: 10-90%RH (0 to 50 ° C)

DC24V (DC18V -35V) Up to 0.3A

Up to 2.5W

H338 × W146 × D160mm (excluding cable ground part)

Approximately 3.7kg

Click on the part number for more information about each product

Other products of New Cosmos Electric

Reviews shown here are reviews of companies.


View more products of New Cosmos Electric

About Company Handling This Product

Response Rate

100.0%


Response Time

28.8hrs

Company Overview

New Cosmos Electric, a company founded in 1934 and headquartered in Osaka, Japan, is a manufacturer and suppli...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree