Image | Part Number | Price (excluding tax) | Harmonic superposition range | Current measurement accuracy (peak) | Current measurement accuracy (RMS) | Current measurement range (peak) | Voltage setting accuracy | Voltage setting distortion | Voltage setting resolution | Voltage setting Load regulation | Voltage setting range | Voltage setting line regulation | Voltage measurement accuracy | Voltage measurement range | DC output (single phase mode) current | DC output (single phase mode) voltage | DC output (single phase mode) power | DC output (three-phase mode/each phase) current | DC output (three-phase mode/each phase) voltage | DC output (three-phase mode/each phase) power | Maximum current (single phase mode) RMS/Peak | Maximum current (three-phase mode/each phase) RMS/Peak | Maximum power | Frequency setting accuracy | Frequency setting range | Each phase | Efficiency | Output phase | Input rating current | Input rating Voltage range | Input rating Power factor | Protection function |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
61830 |
Available upon quote |
Up to 50th order @50/60Hz fundamental frequency |
0.4%+0.6%F.S. |
0.4%+0.3%F.S. |
150A |
0.2%+0.2%F.S. |
<0.5%@50Hz/60Hz, <0.8% 30Hz~100Hz |
0.1V |
0.2% |
0~300VLN/0~520VLL |
0.1% |
0.2%+0.2%F.S. |
0~300V |
75A |
424V |
15kVA |
25A |
424V |
5kVA |
150A/450A |
50A/150A |
30kVA |
0.01% |
30Hz~100Hz |
10kVA |
80% (Typical) |
Single phase/three phase switching |
125A Max./Phase (3Φ200V~240V) |
3Φ200~240V±10%VLL, 47~63Hz |
0.99 (Typical) |
OVP,OCP,OPP,OTP,FAN |
![]() |
61845 |
Available upon quote |
Up to 50th order @50/60Hz fundamental frequency |
0.4%+0.6%F.S. |
0.4%+0.3%F.S. |
225A |
0.2%+0.2%F.S. |
<0.5%@50Hz/60Hz, <0.8% 30Hz~100Hz |
0.1V |
0.2% |
0~300VLN/0~520VLL |
0.1% |
0.2%+0.2%F.S. |
0~300V |
112.5A |
424V |
22.5kVA |
37.5A |
424V |
7.5kVA |
225A/675A |
75A/225A |
45kVA |
0.01% |
30Hz~100Hz |
15kVA |
80% (Typical) |
Single phase/three phase switching |
190A Max./Phase (3Φ200V~240V) |
3Φ200~240V±10%VLL, 47~63Hz |
0.99 (Typical) |
OVP,OCP,OPP,OTP,FAN |
![]() |
61860 |
Available upon quote |
Up to 50th order @50/60Hz fundamental frequency |
0.4%+0.6%F.S. |
0.4%+0.3%F.S. |
300A |
0.2%+0.2%F.S. |
<0.5%@50Hz/60Hz, <0.8% 30Hz~100Hz |
0.1V |
0.2% |
0~300VLN/0~520VLL |
0.1% |
0.2%+0.2%F.S. |
0~300V |
150A |
424V |
30kVA |
50A |
424V |
10kVA |
300A/900A |
100A/300A |
60kVA |
0.01% |
30Hz~100Hz |
20kVA |
80% (Typical) |
Single phase/three phase switching |
250A Max./Phase (3Φ200V~240V) |
3Φ200~240V±10%VLL, 47~63Hz |
0.99 (Typical) |
OVP,OCP,OPP,OTP,FAN |