Roberval type load cell for scales - for low capacity scales (BCL)-BCL-300GM-A
Roberval type load cell for scales - for low capacity scales (BCL)-Sanyu Electronics Industry Co., Ltd.

Roberval type load cell for scales - for low capacity scales (BCL)
Sanyu Electronics Industry Co., Ltd.

Sanyu Electronics Industry Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

84.1hours


About This Product

MinebeaMitsumi's load cells (load transducers) use strain gauges developed in-house to convert force or mass such as tension or compression into electrical signals. It connects to measuring instruments) and performs display, output (analog/digital), recording, control, monitoring, etc.

■Applications

・ Platform scale, truck scale ・Weight management and control of tank/hopper scales ・Press machine load management - Commercial scales, special measuring instruments ・High-speed weighing instruments, process weighing systems (high-speed filling machines, checker scales, post scales, sorters) ・Monitoring control of robot built-in load There are other model numbers available.

  • Product

    Roberval type load cell for scales - for low capacity scales (BCL)

Share this product


490+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Roberval type load cell for scales - for low capacity scales (BCL)

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Nonlinearity Temperature effect at zero point Zero balance Limit overload Material of strain body Mass Error Allowable overload Allowable temperature range Repeatability Insulation resistance (Bridge-Body) Loading surface size Center of cumulative surface Temperature compensation range Maximum applied voltage Recommended applied voltage Rated capacity (R.C.) Rated displacement Rated output (R.O.) Natural frequency Output resistance Temperature effect on output Input resistance Protection class Hysteresis Cable specifications Creep recovery Creep
Roberval type load cell for scales - for low capacity scales (BCL)-Part Number-BCL-300GM-A

BCL-300GM-A

Available upon quote

0,02%R.O.

0.04%R.O./10℃

±0.04mV/V

200%R.C.

AL alloy

Approximately 40g

Load 1/2 of the rated load at an eccentric position of 50 mm, and within ±0.02% R.O.

150%R.C.

-10℃to50℃

0,02%R.O.

2,000MΩ or more (DC50V)

Maximum 200mm x 200mm

Make sure that the center of the loading surface and the center of the load cell match.

-10℃to50℃

15V

10V or less

2.942N (300gf)

-

1.6mV/V±0.2mV/V

-

350±5Ω

0.02%LOAD/10℃

420+30-20Ω

IP40

0,02%R.O.

Φ3.2 4-core shielded 40cm direct connection

0,02%R.O./20min

0,02%R.O./20min

Roberval type load cell for scales - for low capacity scales (BCL)-Part Number-BCL-600GM-A

BCL-600GM-A

Available upon quote

0,02%R.O.

0.04%R.O./10℃

±0.04mV/V

200%R.C.

AL alloy

Approximately 40g

Load 1/2 of the rated load at an eccentric position of 50 mm, and within ±0.02% R.O.

150%R.C.

-10℃to50℃

0,02%R.O.

2,000MΩ or more (DC50V)

Maximum 200mm x 200mm

Make sure that the center of the loading surface and the center of the load cell match.

-10℃to50℃

15V

10V or less

5.884N (600gf)

-

1.6mV/V±0.2mV/V

-

350±5Ω

0.02%LOAD/10℃

420+30-20Ω

IP40

0,02%R.O.

Φ3.2 4-core shielded 40cm direct connection

0,02%R.O./20min

0,02%R.O./20min

Roberval type load cell for scales - for low capacity scales (BCL)-Part Number-BCL-1.2K-A

BCL-1.2K-A

Available upon quote

0,02%R.O.

0.04%R.O./10℃

±0.04mV/V

200%R.C.

AL alloy

Approximately 40g

Loading 1/2 of the rated load with an offset of 75 mm, within ±0.02% R.O.

150%R.C.

-10℃to50℃

0,02%R.O.

2,000MΩ or more (DC50V)

Maximum 300mm x 300mm

Make sure that the center of the loading surface and the center of the load cell match.

-10℃to50℃

15V

10V or less

11.77N (1.2kgf)

-

1.6mV/V±0.2mV/V

-

350±5Ω

0.02%LOAD/10℃

420+30-20Ω

IP40

0,02%R.O.

Φ3.2 4-core shielded 40cm direct connection

0,02%R.O./20min

0,02%R.O./20min

Roberval type load cell for scales - for low capacity scales (BCL)-Part Number-BCL-1.5K-A

BCL-1.5K-A

Available upon quote

0,02%R.O.

0.04%R.O./10℃

±0.04mV/V

200%R.C.

AL alloy

Approximately 40g

Loading 1/2 of the rated load with an offset of 75 mm, within ±0.02% R.O.

150%R.C.

-10℃to50℃

0,02%R.O.

2,000MΩ or more (DC50V)

Maximum 300mm x 300mm

Make sure that the center of the loading surface and the center of the load cell match.

-10℃to50℃

15V

10V or less

14.71N (1.5kgf)

-

1.6mV/V±0.2mV/V

-

350±5Ω

0.02%LOAD/10℃

420+30-20Ω

IP40

0,02%R.O.

Φ3.2 4-core shielded 40cm direct connection

0,02%R.O./20min

0,02%R.O./20min

Roberval type load cell for scales - for low capacity scales (BCL)-Part Number-BCL-3K-A

BCL-3K-A

Available upon quote

0,02%R.O.

0.04%R.O./10℃

±0.04mV/V

200%R.C.

AL alloy

Approximately 40g

Loading 1/2 of the rated load with an offset of 75 mm, within ±0.02% R.O.

150%R.C.

-10℃to50℃

0,02%R.O.

2,000MΩ or more (DC50V)

Maximum 300mm x 300mm

Make sure that the center of the loading surface and the center of the load cell match.

-10℃to50℃

15V

10V or less

29.42N (3kgf)

-

1.6mV/V±0.2mV/V

-

350±5Ω

0.02%LOAD/10℃

420+30-20Ω

IP40

0,02%R.O.

Φ3.2 4-core shielded 40cm direct connection

0,02%R.O./20min

0,02%R.O./20min

Roberval type load cell for scales - for low capacity scales (BCL)-Part Number-BCL-4.5K-A

BCL-4.5K-A

Available upon quote

0,02%R.O.

0.04%R.O./10℃

±0.04mV/V

200%R.C.

AL alloy

Approximately 40g

Loading 1/2 of the rated load with an offset of 75 mm, within ±0.02% R.O.

150%R.C.

-10℃to50℃

0,02%R.O.

2,000MΩ or more (DC50V)

Maximum 300mm x 300mm

Make sure that the center of the loading surface and the center of the load cell match.

-10℃to50℃

15V

10V or less

44.13N (4.5kgf)

-

1.6mV/V±0.2mV/V

-

350±5Ω

0.02%LOAD/10℃

420+30-20Ω

IP40

0,02%R.O.

Φ3.2 4-core shielded 40cm direct connection

0,02%R.O./20min

0,02%R.O./20min

Roberval type load cell for scales - for low capacity scales (BCL)-Part Number-BCL-300GM-C3

BCL-300GM-C3

Available upon quote

0,015%R.O.

0.014%R.O./10℃

±0.04mV/V

300%R.C.

Aluminum alloy

Approximately 70g

Loading 1/2 of the rated capacity at an eccentric position of 50 mm, within ±0.02% R.O.

200%R.C.

-10℃to40℃

0,010%R.O.

2,000MΩ or more (DC50V)

Maximum 200mm x 200mm

Make sure that the center of the loading surface and the center of the load cell match.

-10℃to40℃

15V

10V or less

300g

0.25mm

0.9mV/V±0.1mV/V

80Hz

350±5Ω

0.012%LOAD/10℃

420+30-20Ω

IP40

0,015%R.O.

Φ3.2 40cm with 4-core shield

0,016%R.O./30min

0,016%R.O./30min

Roberval type load cell for scales - for low capacity scales (BCL)-Part Number-BCL-600GM-C3

BCL-600GM-C3

Available upon quote

0,015%R.O.

0.014%R.O./10℃

±0.04mV/V

300%R.C.

Aluminum alloy

Approximately 70g

Loading 1/2 of the rated capacity at an eccentric position of 50 mm, within ±0.02% R.O.

200%R.C.

-10℃to40℃

0,010%R.O.

2,000MΩ or more (DC50V)

Maximum 200mm x 200mm

Make sure that the center of the loading surface and the center of the load cell match.

-10℃to40℃

15V

10V or less

600g

0.25mm

0.9mV/V±0.1mV/V

100Hz

350±5Ω

0.012%LOAD/10℃

420+30-20Ω

IP40

0,015%R.O.

Φ3.2 40cm with 4-core shield

0,016%R.O./30min

0,016%R.O./30min

Roberval type load cell for scales - for low capacity scales (BCL)-Part Number-BCL-1.2K-C3

BCL-1.2K-C3

Available upon quote

0,015%R.O.

0.014%R.O./10℃

±0.04mV/V

300%R.C.

Aluminum alloy

Approximately 70g

Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O.

200%R.C.

-10℃to40℃

0,010%R.O.

2,000MΩ or more (DC50V)

Maximum 300mm x 300mm

Make sure that the center of the loading surface and the center of the load cell match.

-10℃to40℃

15V

10V or less

1.2kg

0.25mm

0.9mV/V±0.1mV/V

200Hz

350±5Ω

0.012%LOAD/10℃

420+30-20Ω

IP40

0,015%R.O.

Φ3.2 40cm with 4-core shield

0,016%R.O./30min

0,016%R.O./30min

Roberval type load cell for scales - for low capacity scales (BCL)-Part Number-BCL-1.5K-C3

BCL-1.5K-C3

Available upon quote

0,015%R.O.

0.014%R.O./10℃

±0.04mV/V

300%R.C.

Aluminum alloy

Approximately 70g

Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O.

200%R.C.

-10℃to40℃

0,010%R.O.

2,000MΩ or more (DC50V)

Maximum 300mm x 300mm

Make sure that the center of the loading surface and the center of the load cell match.

-10℃to40℃

15V

10V or less

1.5kg

0.25mm

0.9mV/V±0.1mV/V

210Hz

350±5Ω

0.012%LOAD/10℃

420+30-20Ω

IP40

0,015%R.O.

Φ3.2 40cm with 4-core shield

0,016%R.O./30min

0,016%R.O./30min

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Load Cells Products

Other products of Sanyu Electronics Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Sanyu Electronics Industry Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

84.1hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree