Roberval type load cell for scales - for medium capacity scales (C2G1)-C2G1-6K-A
Roberval type load cell for scales - for medium capacity scales (C2G1)-Sanyu Electronics Industry Co., Ltd.

Roberval type load cell for scales - for medium capacity scales (C2G1)
Sanyu Electronics Industry Co., Ltd.


About This Product

MinebeaMitsumi's load cells (load transducers) use strain gauges developed in-house to convert force or mass such as tension or compression into electrical signals. It connects to measuring instruments) and performs display, output (analog/digital), recording, control, monitoring, etc. ■Applications ・ Platform scale, truck scale ・Weight management and control of tank/hopper scales ・Press machine load management - Commercial scales, special measuring instruments ・High-speed weighing instruments, process weighing systems (high-speed filling machines, checker scales, post scales, sorters) ・Monitoring control of robot built-in load There are other model numbers available.

  • Product

    Roberval type load cell for scales - for medium capacity scales (C2G1)

Share this product


230+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Roberval type load cell for scales - for medium capacity scales (C2G1)

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Allowable overload Allowable temperature range Cable Center of cumulative surface Creep Creep recovery Error Hysteresis Input resistance Insulation resistance (Bridge-Body) Limit overload Loading surface size Mass Material of strain body Maximum applied voltage Natural frequency Nonlinearity Output resistance Protection class Rated capacity (R.C.) Rated displacement Rated output (R.O.) Recommended applied voltage Repeatability RoHS Surface treatment Temperature compensation range Temperature effect at zero point Temperature effect on output Zero balance
Roberval type load cell for scales - for medium capacity scales (C2G1)-Part Number-C2G1-6K-A

C2G1-6K-A

Available upon quote 150%R.C. -10℃to50℃ Φ3.2 4-core shielded 40cm direct connection Make sure that the center of the loading surface and the center of the load cell match. 0,02%R.O./20min 0,02%R.O./20min Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O. 0,015%R.O. 420+30-20Ω 2,000MΩ or more (DC50V) 200%R.C. Maximum 300mm x 300mm Approximately 200g AL alloy 20V - 0,015%R.O. 350±5Ω IP64 equivalent (main unit only) 58.84N (6kgf) - 2.0mV/V±0.2mV/V 12V or less 0,02%R.O. Compatibility - -10℃to50℃ 0.04%R.O./10℃ 0.012%LOAD/10℃ ±0.1mV/V
Roberval type load cell for scales - for medium capacity scales (C2G1)-Part Number-C2G1-10K-A

C2G1-10K-A

Available upon quote 150%R.C. -10℃to50℃ Φ3.2 4-core shielded 40cm direct connection Make sure that the center of the loading surface and the center of the load cell match. 0,02%R.O./20min 0,02%R.O./20min Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O. 0,015%R.O. 420+30-20Ω 2,000MΩ or more (DC50V) 200%R.C. Maximum 300mm x 300mm Approximately 200g AL alloy 20V - 0,015%R.O. 350±5Ω IP64 equivalent (main unit only) 98.07N (10kgf) - 2.0mV/V±0.2mV/V 12V or less 0,02%R.O. Compatibility - -10℃to50℃ 0.04%R.O./10℃ 0.012%LOAD/10℃ ±0.1mV/V
Roberval type load cell for scales - for medium capacity scales (C2G1)-Part Number-C2G1-12K-A

C2G1-12K-A

Available upon quote 150%R.C. -10℃to50℃ Φ3.2 4-core shielded 40cm direct connection Make sure that the center of the loading surface and the center of the load cell match. 0,02%R.O./20min 0,02%R.O./20min Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O. 0,015%R.O. 420+30-20Ω 2,000MΩ or more (DC50V) 200%R.C. Maximum 300mm x 300mm Approximately 200g AL alloy 20V - 0,015%R.O. 350±5Ω IP64 equivalent (main unit only) 117.7N (12kgf) - 2.0mV/V±0.2mV/V 12V or less 0,02%R.O. Compatibility - -10℃to50℃ 0.04%R.O./10℃ 0.012%LOAD/10℃ ±0.1mV/V
Roberval type load cell for scales - for medium capacity scales (C2G1)-Part Number-C2G1-15K-A

C2G1-15K-A

Available upon quote 150%R.C. -10℃to50℃ Φ3.2 4-core shielded 40cm direct connection Make sure that the center of the loading surface and the center of the load cell match. 0,02%R.O./20min 0,02%R.O./20min Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O. 0,015%R.O. 420+30-20Ω 2,000MΩ or more (DC50V) 200%R.C. Maximum 300mm x 300mm Approximately 200g AL alloy 20V - 0,015%R.O. 350±5Ω IP64 equivalent (main unit only) 147.1N (15kgf) - 2.0mV/V±0.2mV/V 12V or less 0,02%R.O. Compatibility - -10℃to50℃ 0.04%R.O./10℃ 0.012%LOAD/10℃ ±0.1mV/V
Roberval type load cell for scales - for medium capacity scales (C2G1)-Part Number-C2G1-20K-A

C2G1-20K-A

Available upon quote 150%R.C. -10℃to50℃ Φ3.2 4-core shielded 40cm direct connection Make sure that the center of the loading surface and the center of the load cell match. 0,02%R.O./20min 0,02%R.O./20min Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O. 0,015%R.O. 420+30-20Ω 2,000MΩ or more (DC50V) 200%R.C. Maximum 300mm x 300mm Approximately 200g AL alloy 20V - 0,015%R.O. 350±5Ω IP64 equivalent (main unit only) 196.1N (20kgf) - 2.0mV/V±0.2mV/V 12V or less 0,02%R.O. Compatibility - -10℃to50℃ 0.04%R.O./10℃ 0.012%LOAD/10℃ ±0.1mV/V
Roberval type load cell for scales - for medium capacity scales (C2G1)-Part Number-C2G1-25K-A

C2G1-25K-A

Available upon quote 150%R.C. -10℃to50℃ Φ3.2 4-core shielded 40cm direct connection Make sure that the center of the loading surface and the center of the load cell match. 0,02%R.O./20min 0,02%R.O./20min Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O. 0,015%R.O. 420+30-20Ω 2,000MΩ or more (DC50V) 200%R.C. Maximum 300mm x 300mm Approximately 200g AL alloy 20V - 0,015%R.O. 350±5Ω IP64 equivalent (main unit only) 245.2N (25kgf) - 2.0mV/V±0.2mV/V 12V or less 0,02%R.O. Compatibility - -10℃to50℃ 0.04%R.O./10℃ 0.012%LOAD/10℃ ±0.1mV/V
Roberval type load cell for scales - for medium capacity scales (C2G1)-Part Number-C2G1-30K-A

C2G1-30K-A

Available upon quote 150%R.C. -10℃to50℃ Φ3.2 4-core shielded 40cm direct connection Make sure that the center of the loading surface and the center of the load cell match. 0,02%R.O./20min 0,02%R.O./20min Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O. 0,015%R.O. 420+30-20Ω 2,000MΩ or more (DC50V) 200%R.C. Maximum 300mm x 300mm Approximately 200g AL alloy 20V - 0,015%R.O. 350±5Ω IP64 equivalent (main unit only) 294.2N (30kgf) - 2.0mV/V±0.2mV/V 12V or less 0,02%R.O. Compatibility - -10℃to50℃ 0.04%R.O./10℃ 0.012%LOAD/10℃ ±0.1mV/V
Roberval type load cell for scales - for medium capacity scales (C2G1)-Part Number-C2G1-35K-A

C2G1-35K-A

Available upon quote 150%R.C. -10℃to50℃ Φ3.2 4-core shielded 40cm direct connection Make sure that the center of the loading surface and the center of the load cell match. 0,02%R.O./20min 0,02%R.O./20min Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O. 0,015%R.O. 420+30-20Ω 2,000MΩ or more (DC50V) 200%R.C. Maximum 300mm x 300mm Approximately 200g AL alloy 20V - 0,015%R.O. 350±5Ω IP64 equivalent (main unit only) 343.2N (35kgf) - 2.0mV/V±0.2mV/V 12V or less 0,02%R.O. Compatibility - -10℃to50℃ 0.04%R.O./10℃ 0.012%LOAD/10℃ ±0.1mV/V
Roberval type load cell for scales - for medium capacity scales (C2G1)-Part Number-C2G1-50K-A

C2G1-50K-A

Available upon quote 150%R.C. -10℃to50℃ Φ3.2 4-core shielded 40cm direct connection Make sure that the center of the loading surface and the center of the load cell match. 0,02%R.O./20min 0,02%R.O./20min Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O. 0,015%R.O. 420+30-20Ω 2,000MΩ or more (DC50V) 200%R.C. Maximum 300mm x 300mm Approximately 200g AL alloy 20V - 0,015%R.O. 350±5Ω IP64 equivalent (main unit only) 490.3N (50kgf) - 2.0mV/V±0.2mV/V 12V or less 0,02%R.O. Compatibility - -10℃to50℃ 0.04%R.O./10℃ 0.012%LOAD/10℃ ±0.1mV/V
Roberval type load cell for scales - for medium capacity scales (C2G1)-Part Number-C2G1-6K-A-C6

C2G1-6K-A-C6

Available upon quote 150%R.C. -10℃to40℃ Φ4.7 6-core shielded 40cm Make sure that the center of the loading surface and the center of the load cell match. 0,008%R.O./30min 0,008%R.O./30min Loading 1/2 of the rated capacity with an offset of 75 mm, within ±0.02% R.O. 0,012%R.O. 420+30-20Ω 2,000MΩ or more (DC50V) 200%R.C. Maximum 300mm x 300mm Approximately 200g Aluminum alloy 20V 220Hz 0,012%R.O. 350±5Ω IP64 6kg 0.62mm 2.0mV/V±0.2mV/V 12V or less 0,010%R.O. - Anodized aluminum -10℃to40℃ 0.014%R.O./10℃ 0.010%LOAD/10℃ ±0.1mV/V

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Sanyu Electronics Industry Co., Ltd.


View more products of Sanyu Electronics Industry Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree