All Categories
History
Product
Digital indicator for built-in control panelHandling Company
Sanyu Electronics Industry Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Nonlinearity | Zero point adjustment range | Applicable converter | Number of views | Load display Display range | Load display indicator | Load display Display increment | Load display Over display | Status display | Effect of temperature Zero point | Effects of temperature Sensitivity | Decimal point display | External control function ZERO | External control function LOCK | External control function HOLD | External control function A/Z OFF | External control function A/Z | Front panel sheet key switch function ZERO/◀ | Front panel sheet key switch function S*/◀ | Front panel sheet key switch function A/Z OFF | Front panel sheet key switch function A/Z | Judgment display | Input range | Input filter | Input noise | Bridge power supply | Comparator function setting number | Comparator function setting value | CHECK | A/D sampling |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Csd891b |
Available upon quote |
0.01% F.S. |
-2.5mV/V~2.5mV/V |
Up to 4 strain gauge transducers (350Ω) can be connected |
20 times/s (4 times/s, 50 times/s, 100 times/s switchable) |
-9,999~99,999 |
Red 7 segment LED, character height 8mm |
1 (2, 5, 10 switchable) |
-OL" when minus over, "OL" when plus over |
RUN, A/Z, LOCK, HOLD, CHECK |
±0.2μV/℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) |
±0.0015%F.S./℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) |
No display, 10^1, 10^2, 10^3, 10^4 switchable |
Same as ZERO key |
Key operation prohibited *Valid during input when inputting a level higher than 100ms or short-circuiting for 100ms or more (level 2ms, 5ms, 10ms, 20ms switchable) |
Display, comparison output, analog output, BCD output, CC-Link output load, RS-232C load output, RS-422/485 load output hold |
Tare weight clear * Valid once with pulse input or pulse width of 50ms or more (pulse width can be switched from 2ms, 5ms, 10ms, 20ms) |
Tare subtraction |
Zero set/set value increment |
S*Set value display/Set value carry |
Tare clear |
Tare subtraction |
S0,S1,S2,S3,S4 |
F.S. can be set with 0.2mV/V~3.1mV/V input (when bridge power supply DC10V) |
4Hz (2Hz, 6Hz, 8Hz, 10Hz switchable) (with digital filter and stabilization filter setting OFF) |
±0.3μVp-p or less (with input filter, digital filter, and stabilization filter default settings) |
DC10V±0.25V within 120mA (DC5V, DC2.5V switchable) With remote sensing function |
S0,S1,S2,S3,S4 5 points |
-99,999~99,999 |
Approximately 0.3mV/V (can be set in the range of approximately 0.1mV/V to 2.4mV/V in approximately 0.1mV/V increments) |
200 times/s (100 times/s, 50 times/s, 20 times/s, 10 times/s switchable) |
Reviews shown here are reviews of companies.