All Categories
History
Product
Digital indicator for tension controlHandling Company
Sanyu Electronics Industry Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Nonlinearity | Zero point adjustment range | Applicable converter | Number of views | Load display Display range | Load display indicator | Load display Display increment | Load display Over display | Status display | Effect of temperature Zero point | Effects of temperature Sensitivity | Contact output signal WS DOWN | Contact output signal HEALTHY | Contact output signal ERROR | Contact output signal DS DOWN | Decimal point display | External control function ZERO | External control function WS DOWN | External control function LOCK | External control function DS&WS DOWN | External control function DS DOWN | Front panel sheet key switch function ◀/ZERO | Front panel sheet key switch function ▶/CHECK | Front panel sheet key switch function FUNC | Input range | Input filter | Input noise | Bridge power supply | CHECK | A/D sampling |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Tmd100 |
Available upon quote |
0.01% F.S. |
-1.9mV/V~1.9mV/V |
One strain gauge type transducer (350Ω) can be connected (one each for 2ch input) |
20 times/s (4 times/s switchable) |
-19,999~99,999 |
Red 7 segment LED, character height 14mm |
1 (2, 5, 10 switchable) |
-OL" when minus over, "OL" when plus over |
HEALTHY, CHECK, DS DOWN, WS DOWN |
±0.2μV/℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) |
±0.0015%F.S./℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) |
When WS DOWN |
When power is turned on |
When various errors occur |
When DS DOWN |
No display, 10^1, 10^2, 10^3, 10^4 switchable |
Same as ZERO key |
WS DOWN |
Key operation prohibited |
DS&WS DOWN |
DS DOWN |
Set value carry up Press at the same time as shift key to set zero |
Set value digit decrease Press at the same time as shift key to turn on check value |
Function mode switching |
F.S. can be set with 0.2mV/V~3.1mV/V input (when bridge power supply DC10V) |
10Hz (with digital filter and stabilization filter setting "0") |
±0.3μVp-p or less (with digital filter and stabilization filter default values) |
DC10V±0.3V within 30mA (DC2.5V switchable) With remote sensing |
Approx. 0.3mV/V (can be set in the range of approx. 0.1mV/V to 3.0mV/V in steps of 0.1mV/V) |
100 times/s (4 times/s, 20 times/s switchable) |
Reviews shown here are reviews of companies.