Image | Part Number | Price (excluding tax) | Drip-proof structure | Adjustment range (unit bar) (accuracy at room temperature) | Shockproof | Vibration resistance | Pressure resistance | Mechanical life | Material | Connection type | Operating temperature (diaphragm seal material) | Hysteresis adjustable | Switching frequency | Current-carrying section cross-sectional area | Tightening torque | Short circuit current | Rated power supply voltage 75volt DC | Rated power supply voltage 50volt DC | Rated power supply voltage 250volt DC | Rated power supply voltage 250volt AC 50/60Hz | Rated power supply voltage 24volt DC | Rated power supply voltage 125volt DC | Rated current (short circuit prevention) | Rated insulation voltage | Rated frequency | Rated thermal current | Rated surge capacity | Over voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
140 |
Available upon quote |
IP65, IP100 (terminal) (EN60529:1991+A1;1999) |
0.3-1.5 (±0.2) |
294m/s^2; 14ms half sine wave |
10g/5~200Hz sine wave |
300bar |
10^6 times (maximum load 50bar) |
Galvanized steel |
G 1/4 |
NBR -30℃-+100℃ |
- |
200 times/min |
0.5 - 1.5mm^2 |
<0.35Nm |
<350amp |
Rated operating current 0.5/0.25amp (Usage classification DC 12/DC 13) |
Rated operating current 1/0.5amp (Usage classification DC 12/DC 13) |
Rated operating current 0.15/0.1amp (Usage classification DC 12/DC 13) |
Rated operating current 2amp (use classification AC 12) |
Rated operating current 2/1amp (Usage classification DC 12/DC 13) |
Rated operating current 0.2/0.1amp (Usage classification DC 12/DC 13) |
Up to 3.5amp |
300volt |
DC and 50/60Hz |
5amp |
4kV |
<2.5kV |
|
141 |
Available upon quote |
IP65, IP100 (terminal) (EN60529:1991+A1;1999) |
50-150 (±5.0) |
294m/s^2; 14ms half sine wave |
10g/5~200Hz sine wave |
600bar |
10^6 times (maximum load 50bar) |
Galvanized steel |
G 1/4 |
NBR -30℃-+100℃ |
- |
200 times/min |
0.5 - 1.5mm^2 |
<0.35Nm |
<350amp |
Rated operating current 0.5/0.25amp (Usage classification DC 12/DC 13) |
Rated operating current 1/0.5amp (Usage classification DC 12/DC 13) |
Rated operating current 0.15/0.1amp (Usage classification DC 12/DC 13) |
Rated operating current 2amp (use classification AC 12) |
Rated operating current 2/1amp (Usage classification DC 12/DC 13) |
Rated operating current 0.2/0.1amp (Usage classification DC 12/DC 13) |
Up to 3.5amp |
300volt |
DC and 50/60Hz |
5amp |
4kV |
<2.5kV |
|
170 |
Available upon quote |
IP65, IP100 (terminal) (EN60529:1991+A1;1999) |
・100bar |
294m/s^2; 14ms half sine wave |
10g/5~200Hz sine wave |
100/300bar |
10^6 times (maximum load 50bar) |
Galvanized steel |
M 10×1 taper |
NBR -30℃-+100℃ |
Adjustable in the range of 10-30%, standard value of hiss is 10-20% |
200 times/min |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
171 |
Available upon quote |
IP65, IP100 (terminal) (EN60529:1991+A1;1999) |
50-200 (±5.0) |
294m/s^2; 14ms half sine wave |
10g/5~200Hz sine wave |
600bar |
10^6 times (maximum load 50bar) |
Galvanized steel |
M 10×1 taper |
NBR -30℃-+100℃ |
Adjustable in the range of 10-30%, standard value of hiss is 10-20% |
200 times/min |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
180 |
Available upon quote |
IP65, IP100 (terminal) (EN60529:1991+A1;1999) |
・100bar |
294m/s^2; 14ms half sine wave |
10g/5~200Hz sine wave |
100/300bar |
10^6 times (maximum load 50bar) |
Galvanized steel |
M 10×1 taper |
NBR -30℃-+100℃ |
Adjustable in the range of 10-30%, standard value of hiss is 10-20% |
200 times/min |
0.5 - 1.5mm^2 |
<0.35Nm |
<350amp |
Rated operating current 1/0.5amp (Usage classification DC 12/DC 13) |
Rated operating current 2/1amp (Usage classification DC 12/DC 13) |
Rated operating current 0.25/0.2amp (Usage classification DC 12/DC 13) |
Rated operating current 4amp (use classification AC 12), 1amp (use classification AC 14) |
Rated operating current 4/4amp (Usage classification DC 12/DC 13) |
Rated operating current 0.3/0.2amp (Usage classification DC 12/DC 13) |
Up to 3.5amp |
300volt |
DC and 50/60Hz |
5amp |
4kV |
<2.5kV |
|
181 |
Available upon quote |
IP65, IP100 (terminal) (EN60529:1991+A1;1999) |
50-200 (±5.0) |
294m/s^2; 14ms half sine wave |
10g/5~200Hz sine wave |
600bar |
10^6 times (maximum load 50bar) |
Galvanized steel |
M 10×1 taper |
NBR -30℃-+100℃ |
Adjustable in the range of 10-30%, standard value of hiss is 10-20% |
200 times/min |
0.5 - 1.5mm^2 |
<0.35Nm |
<350amp |
Rated operating current 1/0.5amp (Usage classification DC 12/DC 13) |
Rated operating current 2/1amp (Usage classification DC 12/DC 13) |
Rated operating current 0.25/0.2amp (Usage classification DC 12/DC 13) |
Rated operating current 4amp (use classification AC 12), 1amp (use classification AC 14) |
Rated operating current 4/4amp (Usage classification DC 12/DC 13) |
Rated operating current 0.3/0.2amp (Usage classification DC 12/DC 13) |
Up to 3.5amp |
300volt |
DC and 50/60Hz |
5amp |
4kV |
<2.5kV |
|
184 |
Available upon quote |
IP65, IP100 (terminal) (EN60529:1991+A1;1999) |
・100bar |
294m/s^2; 14ms half sine wave |
10g/5~200Hz sine wave |
100/300bar |
10^6 times (maximum load 50bar) |
Galvanized steel |
M 10×1 taper |
NBR -30℃-+100℃ |
Adjustable in the range of 10-30%, standard value of hiss is 10-20% |
200 times/min |
0.5 - 1.5mm^2 |
<0.35Nm |
<350amp |
Rated operating current 1/0.5amp (Usage classification DC 12/DC 13) |
Rated operating current 2/1amp (Usage classification DC 12/DC 13) |
Rated operating current 0.25/0.2amp (Usage classification DC 12/DC 13) |
Rated operating current 4amp (use classification AC 12), 1amp (use classification AC 14) |
Rated operating current 4/4amp (Usage classification DC 12/DC 13) |
Rated operating current 0.3/0.2amp (Usage classification DC 12/DC 13) |
Up to 3.5amp |
300volt |
DC and 50/60Hz |
5amp |
4kV |
<2.5kV |
|
185 |
Available upon quote |
IP65, IP100 (terminal) (EN60529:1991+A1;1999) |
50-200 (±5.0) |
294m/s^2; 14ms half sine wave |
10g/5~200Hz sine wave |
600bar |
10^6 times (maximum load 50bar) |
Galvanized steel |
M 10×1 taper |
NBR -30℃-+100℃ |
Adjustable in the range of 10-30%, standard value of hiss is 10-20% |
200 times/min |
0.5 - 1.5mm^2 |
<0.35Nm |
<350amp |
Rated operating current 1/0.5amp (Usage classification DC 12/DC 13) |
Rated operating current 2/1amp (Usage classification DC 12/DC 13) |
Rated operating current 0.25/0.2amp (Usage classification DC 12/DC 13) |
Rated operating current 4amp (use classification AC 12), 1amp (use classification AC 14) |
Rated operating current 4/4amp (Usage classification DC 12/DC 13) |
Rated operating current 0.3/0.2amp (Usage classification DC 12/DC 13) |
Up to 3.5amp |
300volt |
DC and 50/60Hz |
5amp |
4kV |
<2.5kV |
|
190 |
Available upon quote |
IP65, IP100 (terminal) (EN60529:1991+A1;1999) |
・100bar |
294m/s^2; 14ms half sine wave |
10g/5~200Hz sine wave |
100/300bar |
10^6 times (maximum load 50bar) |
Galvanized steel |
M 10×1 taper |
NBR -30℃-+100℃ |
Adjustable in the range of 10-30%, standard value of hiss is 10-20% |
200 times/min |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
191 |
Available upon quote |
IP65, IP100 (terminal) (EN60529:1991+A1;1999) |
50-200 (±5.0) |
294m/s^2; 14ms half sine wave |
10g/5~200Hz sine wave |
600bar |
10^6 times (maximum load 50bar) |
Galvanized steel |
M 10×1 taper |
NBR -30℃-+100℃ |
Adjustable in the range of 10-30%, standard value of hiss is 10-20% |
200 times/min |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - |