Product
Adjustable settings/C contact (SPDT) pressure switch MS-PSHandling Company
LCI Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accuracy at 25℃ (bar) | Allowable pressure (static pressure) (bar) | Body width across flats 24mm | Connection (screw) | Diaphragm | Fixed hysteresis | Gold plated contacts | Housing material | Material | Maximum current | Maximum cycle rate | Maximum hysteresis at 25°C | Maximum load (gold contacts) | Measurement method | Mechanical life | Option-1 | Option-2 | Pressure range (bar) | Protection class | Silver plated contacts | Switch rating | Switch specifications | Temperature range | Usable voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MS2 |
Available upon quote | ±0.2 |
Brass: 300 Galvanized steel: 300 SUS316 equivalent: 300 |
〇 |
R1/8 (*Taper thread) R1/4 (*Taper thread) G1/4 (*parallel thread) G1/8 (*parallel thread) |
HNBR (-25~+140℃) FKM (-5~+90℃) (optional) Silicon (red) (-30~+120℃) (optional) EPDM (-20~+110℃) (optional) |
〇 | 〇 | PA (polyamide) |
Brass (brass) galvanized carbon steel SUS316 (equivalent) |
<30mA, 6A |
120 times/min (diaphragm) 10 times/min (stainless steel diaphragm) |
Below 15℃ | 30mA/DC30V | Diaphragm type | 10^6 (number of operations) |
With snubber Specify the set value (for example, "T2" means the switch will operate when the pressure rises to 2 bar) Specify the set value (for example, if "T5D", the switch will operate when the pressure drops to 5 bar) |
Gold-plated contacts (optional when the current on the circuit is low) Oil-free treatment that uses high-purity oxygen Test product with gas fluid |
0.2~2 |
IP00 (main body) IP65 (when using Cap13) IP54 (when using Cap16) IP67 (optional) (when using Cap14, M12 electrical connector) |
〇 |
6 (2) A/AC250V 2 (1) A/DC24V |
C contact (SPDT) | -30~+140℃ (depending on diaphragm/gasket material) | DC12V, DC24V, DC48V, AC110V, AC220V, AC250V | |
MS10 |
Available upon quote | ±0.4 |
Brass: 300 Galvanized steel: 300 SUS316 equivalent: 300 |
〇 |
R1/8 (*Taper thread) R1/4 (*Taper thread) G1/4 (*parallel thread) G1/8 (*parallel thread) |
HNBR (-25~+140℃) FKM (-5~+90℃) (optional) Silicon (red) (-30~+120℃) (optional) EPDM (-20~+110℃) (optional) |
〇 | 〇 | PA (polyamide) |
Brass (brass) galvanized carbon steel SUS316 (equivalent) |
<30mA, 6A |
120 times/min (diaphragm) 10 times/min (stainless steel diaphragm) |
Below 15℃ | 30mA/DC30V | Diaphragm type | 10^6 (number of operations) |
With snubber Specify the set value (for example, "T2" means the switch will operate when the pressure rises to 2 bar) Specify the set value (for example, if "T5D", the switch will operate when the pressure drops to 5 bar) |
Gold-plated contacts (optional when the current on the circuit is low) Oil-free treatment that uses high-purity oxygen Test product with gas fluid |
1~10 |
IP00 (main body) IP65 (when using Cap13) IP54 (when using Cap16) IP67 (optional) (when using Cap14, M12 electrical connector) |
〇 |
6 (2) A/AC250V 2 (1) A/DC24V |
C contact (SPDT) | -30~+140℃ (depending on diaphragm/gasket material) | DC12V, DC24V, DC48V, AC110V, AC220V, AC250V | |
MS50 |
Available upon quote | ±2 |
Brass: 300 Galvanized steel: 300 SUS316 equivalent: 300 |
〇 |
R1/8 (*Taper thread) R1/4 (*Taper thread) G1/4 (*parallel thread) G1/8 (*parallel thread) |
HNBR (-25~+140℃) FKM (-5~+90℃) (optional) Silicon (red) (-30~+120℃) (optional) EPDM (-20~+110℃) (optional) |
〇 | 〇 | PA (polyamide) |
Brass (brass) galvanized carbon steel SUS316 (equivalent) |
<30mA, 6A |
120 times/min (diaphragm) 10 times/min (stainless steel diaphragm) |
Below 15℃ | 30mA/DC30V | Diaphragm type | 10^6 (number of operations) |
With snubber Specify the set value (for example, "T2" means the switch will operate when the pressure rises to 2 bar) Specify the set value (for example, if "T5D", the switch will operate when the pressure drops to 5 bar) |
Gold-plated contacts (optional when the current on the circuit is low) Oil-free treatment that uses high-purity oxygen Test product with gas fluid |
10~50 |
IP00 (main body) IP65 (when using Cap13) IP54 (when using Cap16) IP67 (optional) (when using Cap14, M12 electrical connector) |
〇 |
6 (2) A/AC250V 2 (1) A/DC24V |
C contact (SPDT) | -30~+140℃ (depending on diaphragm/gasket material) | DC12V, DC24V, DC48V, AC110V, AC220V, AC250V | |
MS100 |
Available upon quote | ±3 |
Brass: 300 Galvanized steel: 300 SUS316 equivalent: 300 |
〇 |
R1/8 (*Taper thread) R1/4 (*Taper thread) G1/4 (*parallel thread) G1/8 (*parallel thread) |
HNBR (-25~+140℃) FKM (-5~+90℃) (optional) Silicon (red) (-30~+120℃) (optional) EPDM (-20~+110℃) (optional) |
〇 | 〇 | PA (polyamide) |
Brass (brass) galvanized carbon steel SUS316 (equivalent) |
<30mA, 6A |
120 times/min (diaphragm) 10 times/min (stainless steel diaphragm) |
Below 15℃ | 30mA/DC30V | Diaphragm type | 10^6 (number of operations) |
With snubber Specify the set value (for example, "T2" means the switch will operate when the pressure rises to 2 bar) Specify the set value (for example, if "T5D", the switch will operate when the pressure drops to 5 bar) |
Gold-plated contacts (optional when the current on the circuit is low) Oil-free treatment that uses high-purity oxygen Test product with gas fluid |
10~100 |
IP00 (main body) IP65 (when using Cap13) IP54 (when using Cap16) IP67 (optional) (when using Cap14, M12 electrical connector) |
〇 |
6 (2) A/AC250V 2 (1) A/DC24V |
C contact (SPDT) | -30~+140℃ (depending on diaphragm/gasket material) | DC12V, DC24V, DC48V, AC110V, AC220V, AC250V | |
PS150 |
Available upon quote | ±5 |
Galvanized steel: 600 SUS316 equivalent: 600 |
〇 |
R1/8 (*Taper thread) R1/4 (*Taper thread) G1/4 (*parallel thread) G1/8 (*parallel thread) |
HNBR (-25~+140℃) FKM (-5~+90℃) (optional) Silicon (red) (-30~+120℃) (optional) EPDM (-20~+110℃) (optional) |
〇 | 〇 | PA (polyamide) |
Brass (brass) galvanized carbon steel SUS316 (equivalent) |
<30mA, 6A | 60 times/min | Below 15℃ | 30mA/DC30V | Piston type | 10^6 (number of operations) |
With snubber Specify the set value (for example, "T2" means the switch will operate when the pressure rises to 2 bar) Specify the set value (for example, if "T5D", the switch will operate when the pressure drops to 5 bar) |
Gold-plated contacts (optional when the current on the circuit is low) Oil-free treatment that uses high-purity oxygen Test product with gas fluid |
30~150 |
IP00 (main body) IP65 (when using Cap13) IP54 (when using Cap16) IP67 (optional) (when using Cap14, M12 electrical connector) |
〇 |
6 (2) A/AC250V 2 (1) A/DC24V |
C contact (SPDT) | -30~+140℃ (depending on diaphragm/gasket material) | DC12V, DC24V, DC48V, AC110V, AC220V, AC250V | |
PS300 |
Available upon quote | ±15 |
Galvanized steel: 600 SUS316 equivalent: 600 |
〇 |
R1/8 (*Taper thread) R1/4 (*Taper thread) G1/4 (*parallel thread) G1/8 (*parallel thread) |
HNBR (-25~+140℃) FKM (-5~+90℃) (optional) Silicon (red) (-30~+120℃) (optional) EPDM (-20~+110℃) (optional) |
〇 | 〇 | PA (polyamide) |
Brass (brass) galvanized carbon steel SUS316 (equivalent) |
<30mA, 6A | 60 times/min | Below 15℃ | 30mA/DC30V | Piston type | 10^6 (number of operations) |
With snubber Specify the set value (for example, "T2" means the switch will operate when the pressure rises to 2 bar) Specify the set value (for example, if "T5D", the switch will operate when the pressure drops to 5 bar) |
Gold-plated contacts (optional when the current on the circuit is low) Oil-free treatment that uses high-purity oxygen Test product with gas fluid |
50~300 |
IP00 (main body) IP65 (when using Cap13) IP54 (when using Cap16) IP67 (optional) (when using Cap14, M12 electrical connector) |
〇 |
6 (2) A/AC250V 2 (1) A/DC24V |
C contact (SPDT) | -30~+140℃ (depending on diaphragm/gasket material) | DC12V, DC24V, DC48V, AC110V, AC220V, AC250V |
Click on the part number for more information about each product