Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX-GMD600-10
Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX-Ikeda Technical Co., Ltd.

Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX
Ikeda Technical Co., Ltd.


About This Product

■Air conditioning with anti-virus technology uses patented technology “Geo-MAX” Geo-MAX is a unique system unlike any other in the world (domestic patent acquired, international patent pending) ■System overview 1.Using high-density polyethylene PE-100 heat exchange tube GA-800 (or GA-600) 2. Bury horizontally with a length of 10 to 50 m (2 to 10 pieces) and blow air using inverter control. 3. Burying depth: 2m (pipe bottom surface) 4.Blowout temperature when using groundwater is approximately 25℃ *GMD800-30 When outside temperature is 35℃ and groundwater temperature is 15℃ 5. Can be installed in any facility that requires air conditioning if there is installation space 6.Low power consumption Running cost: 0.33kw to 1.45kw *Total power consumption of duct fan and water pump By using groundwater, Geo-MAX can create conditions equivalent to those buried 2 meters underground but less than 5 meters underground. The underground temperature is stable throughout the year at 5m below the ground surface. Most common geothermal heat utilization systems require excavation/burying from 5m to 100m. ■What is geothermal heat? Geothermal heat... The first thing that comes to mind is "hot" heat such as hot springs, magma, and geothermal power generation. The heat source is geothermal heat located deep within the earth. The "geothermal heat" referred to here is heat originating from the sun. This refers to heat stored in extremely shallow places, about 5m to 100m underground. I hope you remember well water and limestone caves, which are warm in winter and cold in summer. Also, compared to other natural energies, it is a stable energy that is less affected by weather and climate and will not run out. ■Available facilities ・Factory/Warehouse ・Apartment housing ・Public facilities・Gymnasiums・Arenas ・Single-family house ・Agricultural facilities

  • Product

    Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX

Share this product


480+ people viewing

Last viewed: 7 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

8 Models of Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Air volume (hour) Air volume (min) Capacity Cooling (outside temperature 35℃) Capacity Heating (outside temperature 0℃) Ducted fan power consumption Estimated effectiveness cooling (outside temperature 35℃) Heat exchange tube Heat exchange tube length Outlet temperature* Heating (outside temperature 0℃) Power specifications Pump power consumption Total power consumption
Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX-Part Number-GMD600-10

GMD600-10

Available upon quote 1,800m^3 30m^3 5.5kw 4.1kw 0.08kw 26.6℃ GA-600 (Φ600mm) 10m 6.3℃ Single phase 100V/three phase 200V 0.25kw 0.33kw
Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX-Part Number-GMD600-15

GMD600-15

Available upon quote 2,700m^3 45m^3 8.2kw 6.2kw 0.24kw 26.6℃ GA-600 (Φ600mm) 15m 6.3℃ Single phase 100V/three phase 200V 0.25kw 0.49kw
Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX-Part Number-GMD600-20

GMD600-20

Available upon quote 3,480m^3 58m^3 10.6kw 7.9kw 0.3kw 26.6℃ GA-600 (Φ600mm) 20m 6.3℃ Single phase 100V/three phase 200V 0.25kw 0.55kw
Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX-Part Number-GMD600-30

GMD600-30

Available upon quote 4,800m^3 80m^3 14.6kw 10.9kw 0.54kw 26.6℃ GA-600 (Φ600mm) 30m 6.3℃ Single phase 100V/three phase 200V 0.25kw 0.79kw
Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX-Part Number-GMD800-15

GMD800-15

Available upon quote 3,600m^3 60m^3 10.9kw 8.2kw 0.55kw 26.6℃ GA-800 (Φ800mm) 15m 6.3℃ Three phase 200V 0.25kw 0.80kw
Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX-Part Number-GMD800-30

GMD800-30

Available upon quote 7,080m^3 118m^3 21.5kw 16.1kw 0.81kw 26.6℃ GA-800 (Φ800mm) 30m 6.3℃ Three phase 200V 0.25kw 1.06kw
Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX-Part Number-GMD800-40

GMD800-40

Available upon quote 7,080m^3 118m^3 28.7kw 21.5kw 0.81kw 23.8℃ GA-800 (Φ800mm) 40m 8.4℃ Three phase 200V 0.4kw 1.21kw
Large air volume geothermal heat utilization ventilation air conditioning system Geo-MAX Geo-MAX-Part Number-GMD800-50

GMD800-50

Available upon quote 9,300m^3 155m^3 36.5kw 27.4kw 1.05kw 24.2℃ GA-800 (Φ800mm) 50m 8.1℃ Three phase 200V 0.4kw 1.45kw

Click on the part number for more information about each product