Product
Insertion type ultrasonic flow meter ULSONA DT seriesHandling Company
ITEC SOLUTION Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Accuracy | Analog output | Applicable pipe size | Calendar clock | Communication port | Controller operating temperature | Controller waterproof performance | Digital output | Display content | Display section | Flow velocity resolution | Installation method | Material | Measurement flow rate range | Measurement method | Measuring fluid | Recording medium | Sensor | Sensor part waterproof performance | Sensor section operating temperature | Supply voltage/power consumption | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ULSONA DT series |
Available upon quote | ±0.5% for RD (flow velocity 0.5[m/sec] or more) | CH1 flow rate: DC4-20mA (DC0-24mA) (load resistance ≦500Ω) CH2 temperature, flow rate, negative flow rate (selection): DC 1-5V | DT1: 80~300A DT2: 350~450A DT3: 500~1,000A | Embedded in the base | RS485 (MODBUS RTU 9,600~38,400bps | -5℃~50℃ (controller) | Controller IP65 | CH1 Positive direction flow pulse ((PhotoMOS relay DC30V 500mA) ) CH2 Negative direction flow pulse (PhotoMOS relay DC30V 500mA) CH3 Measurement error (No-voltage contact) | Instantaneous flow rate [㎥/sec][L/sec][L/min][L/hour][㎥/min][㎥/hour] Momentary flow velocity [m/sec] Forward flow rate pulse 0~999999.999[㎥] etc. | 7 inch color LCD with touch panel | 0.003[m/sec] | Saddle type faucet/flange mounting adapter (repair valve) | SUS316 (insertion part), SUS304 (others) | 0.000~±20.000[m/sec] | Transit time method | Water, ultrapure water, construction water, etc. | MicroSD card (2GB MAX) | Ultrasonic oscillator | Sensor part IP65 Connection box IP67 | Sensor (0~55℃) | DC24V (DC9-26V battery operation possible) Approx. 5W or less | Approximately 10kg (depending on shaft length) |