All Categories

History

Heat exchange ventilation system VLR-70E that does not require duct piping and can be used with a wide range of construction methods.-VLR-70#E
Heat exchange ventilation system VLR-70E that does not require duct piping and can be used with a wide range of construction methods.-Nippon Stiebel Co., Ltd.

Heat exchange ventilation system VLR-70E that does not require duct piping and can be used with a wide range of construction methods.
Nippon Stiebel Co., Ltd.

🏗️ Architecture & Construction Use

Nippon Stiebel Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

30.9hours

Relatively Fast Response


About This Product

■Mechanism of VLR-70

Basically, an even number of units are installed, and ventilation and heat exchange are performed while continuing alternate operation of air supply and exhaust every 40 seconds. A total heat exchange type suitable for Japan's hot and humid climate, the heat exchange element is made of aluminum and can be washed with water. VLR-70 consists of a front panel, fan unit, and fresh air hood. The fan unit includes a filter (one indoor and one outdoor), an aluminum heat exchange element, and a fan motor. We have a wide lineup of filters that you can choose from depending on your home environment and desired air quality. Features of VLR-70

■Easy design, construction, and maintenance without the need for large-scale duct piping

Easy to install as it can be installed directly on the wall. Heat exchange ventilation can be installed even in areas where there is no space for duct piping, such as open ceilings, skip floors, and sloped ceilings. Furthermore, we recommend a set of metal pipes (VLR-70#T) that is easy to install and is also compliant with fireproof standards. Since the metal pipe is delivered with insulation applied, there is no need for the process of spraying urethane foam.

■Both large air volume and quietness

Adopts serration technology learned from owl feathers. This technology has also been used in railway pantographs and airplane flaps, and has succeeded in reducing air resistance and noise by reducing the vortices of airflow. This makes it possible to suppress the noise level even though it is a large air volume type.

■Adopts Allele Sweep® that suppresses viruses and odors

The filter uses ``Aller Sweep®,'' which is made of highly safe plant-derived ingredients (extracts of ginkgo biloba, five-leaf berries, etc.) as the main ingredient. In addition to suppressing bacteria, viruses, allergens such as dust mites and cedar pollen, and mold, it has also been confirmed to have a deodorizing effect.

■Aluminum heat exchange element with excellent durability and antibacterial properties

The surface of the aluminum has been processed to have many irregularities that overlap like strata. This treatment increases the surface area, making it act like pores and adsorbing very small water gas molecules. By alternately repeating air supply and exhaust operations, water molecules repeatedly adsorb and desorb, allowing humidity to be exchanged.

■Can be washed with water

The washable heat exchange element allows you to use it cleanly for a long time.

■Ventilation (night purge) mode included as standard

Equipped as standard with a ventilation operation mode that continues exhaust or supply air operation without heat exchange.

  • Product

    Heat exchange ventilation system VLR-70E that does not require duct piping and can be used with a wide range of construction methods.
  • Usage Scenarios

    Architecture & Construction Use

Share this product


160+ people viewing

Last viewed: 4 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

3 Models of Heat exchange ventilation system VLR-70E that does not require duct piping and can be used with a wide range of construction methods.

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Fire damper Metal pipe Body mass (kg) Applicable wall thickness (mm) Rated voltage Fresh air hood color Fresh air hood dimensions (width x height x depth) (mm) Front panel color Front panel dimensions (width x height x depth) (mm) Specification Fan motor Pipe dimensions (width x height) (mm) Controller set (yen/tax not included) Optional items (yen/excluding tax)
Heat exchange ventilation system VLR-70E that does not require duct piping and can be used with a wide range of construction methods.-Part Number-VLR-70#E

VLR-70#E

$ 552.50〜

Nothing

Nothing

Front panel: 0.9
Fan unit: 2.0
Fresh air hood: 0.87

135~300

100V 50/60Hz

Silver (S) /White (W) /Black (B) /Brown (CB)

272x201.2x146.6

White

257x257x45 (open state: 65)

VLR-70E *Non-fire protection specification

Dc motor

166×144×315

For 4 units: 66,000 / For 6 and 8 units: 75,000

CO2 sensor set: 58,000
Humidity sensor set: 35,000
Controller extension cable (50m roll): 7,000

Heat exchange ventilation system VLR-70E that does not require duct piping and can be used with a wide range of construction methods.-Part Number-VLR-70#E/G

VLR-70#E/G

$ 552.50〜

Nothing

Nothing

Front panel: 0.9
Fan unit: 2.0
Fresh air hood: 0.87

135~300

100V 50/60Hz

Silver (S) /White (W) /Black (B) /Brown (CB)

272x201.2x146.6

Matte gray

257x257x45 (open state: 65)

VLR-70E *Non-fire protection specification

Dc motor

166×144×315

For 4 units: 66,000 / For 6 and 8 units: 75,000

CO2 sensor set: 58,000
Humidity sensor set: 35,000
Controller extension cable (50m roll): 7,000

Heat exchange ventilation system VLR-70E that does not require duct piping and can be used with a wide range of construction methods.-Part Number-VLR-70#E/B

VLR-70#E/B

$ 552.50〜

Nothing

Nothing

Front panel: 0.9
Fan unit: 2.0
Fresh air hood: 0.87

135~300

100V 50/60Hz

Silver (S) /White (W) /Black (B) /Brown (CB)

272x201.2x146.6

Matte black

257x257x45 (open state: 65)

VLR-70E *Non-fire protection specification

Dc motor

166×144×315

For 4 units: 66,000 / For 6 and 8 units: 75,000

CO2 sensor set: 58,000
Humidity sensor set: 35,000
Controller extension cable (50m roll): 7,000

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Ventilating Equipment & Systems Products

Other products of Nippon Stiebel Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Nippon Stiebel Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

30.9hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree