Product Image | Part Number | Price (excluding tax) | Electrical conductivity Reference temperature | Electrical conductivity accuracy | Electrical conductivity calibration points | Electrical conductivity range | Electrical conductivity resolution | Electrical conductivity standard solution | Electrical resistivity (resistivity) accuracy | Electrical resistivity (resistivity) range | Electrical resistivity (specific resistance) resolution | ISE (ion) accuracy | ISE (ion) calibration points | ISE (ion) range | ISE (ion) resolution | ISE (ion) unit | ORP (mV) Accuracy | ORP (mV) Resolution | ORP (mV) range | PH accuracy | PH calibration points | PH range | PH resolution | PH standard solution | PH standard solution custom | PX accuracy | PX number of calibration points | PX range | PX resolution | TDS range | TDS resolution | Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OSK 97MD300F-M |
Available upon quote | 20℃, 25℃ | ±1.0%FS | Maximum 3 points | 0.000μS/cm~1,000mS/cm | Minimum 0.001μS/cm, depending on range | 84μS/cm, 1,413μS/cm, 12.88mS/cm | ±1.0%FS | 5.00Ω·cm~20.00MΩ·cm | Minimum 0.01Ω cm | ±0.5% | Maximum 5 points | 1E-9~9.999E9 | Maximum significant figure 4 digits | Mol/L, mmol/L, g/L, mg/L, μg/L, ppm | ±0.3mV or ±0.1% of reading, whichever is greater | 0.1mV | -2,000.00~2,000.0mV | ±0.01pH | Maximum 5 points | -2.00~20.00pH | 0.1, 0.01pH | NIST, GB, DIN buffer | Possible | ±0.02pX | Maximum 5 points | -2.00~20.00 | 0.1, 0.01pX | 0.00mg/L~300g/L | Minimum 0.01mg/L, depending on range | Multi type | |
OSK 97MD300F-MA |
Available upon quote | 20℃, 25℃ | ±1.0%FS | Maximum 3 points | 0.000μS/cm~1,000mS/cm | Minimum 0.001μS/cm, depending on range | 84μS/cm, 1,413μS/cm, 12.88mS/cm | ±1.0%FS | 5.00Ω·cm~20.00MΩ·cm | Minimum 0.01Ω cm | ±0.5% | Maximum 5 points | 1E-9~9.999E9 | Maximum significant figure 4 digits | Mol/L, mmol/L, g/L, mg/L, μg/L, ppm | ±0.3mV or ±0.1% of reading, whichever is greater | 0.1mV | -2,000.00~2,000.0mV | ±0.01pH | Maximum 5 points | -2.00~20.00pH | 0.1, 0.01pH | NIST, GB, DIN buffer | Possible | ±0.02pX | Maximum 5 points | -2.00~20.00 | 0.1, 0.01pX | 0.00mg/L~300g/L | Minimum 0.01mg/L, depending on range | Multi type | |
OSK 97MD300F-PH |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ±0.3mV or ±0.1% of reading, whichever is greater | 0.1mV | -2,000.00~2,000.0mV | ±0.01pH | Maximum 5 points | -2.00~20.00pH | 0.1, 0.01pH | NIST, GB, DIN buffer | Possible | - | - | - | - | 0.00mg/L~300g/L | Minimum 0.01mg/L, depending on range | PH meter | |
OSK 97MD300F-EC |
Available upon quote | 20℃, 25℃ | ±1.0%FS | Maximum 3 points | 0.000μS/cm~1,000mS/cm | Minimum 0.001μS/cm, depending on range | 84μS/cm, 1,413μS/cm, 12.88mS/cm | ±1.0%FS | 5.00Ω·cm~20.00MΩ·cm | Minimum 0.01Ω cm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.00mg/L~300g/L | Minimum 0.01mg/L, depending on range | Electrical conductivity meter | |
OSK 97MD300F-ISE |
Available upon quote | - | - | - | - | - | - | - | - | - | ±0.5% | Maximum 5 points | 1E-9~9.999E9 | Maximum significant figure 4 digits | Mol/L, mmol/L, g/L, mg/L, μg/L, ppm | ±0.3mV or ±0.1% of reading, whichever is greater | 0.1mV | -2,000.00~2,000.0mV | ±0.01pH | Maximum 5 points | -2.00~20.00pH | 0.1, 0.01pH | NIST, GB, DIN buffer | Possible | ±0.02pX | Maximum 5 points | -2.00~20.00 | 0.1, 0.01pX | 0.00mg/L~300g/L | Minimum 0.01mg/L, depending on range | PH/ion meter |
Click on the part number for more information about each product