Product Image | Part Number | Price (excluding tax) | Cleaning pump power consumption | Cleaning tank capacity | Cleaning tank temperature range | Cleaning water volume/pump flow rate | Detailed setting items for each phase | Detergent amount adjustment function | Dimensions (LXDXH mm) | Display | Display content | Door specifications | Drying function | Drying function Air volume | Drying function Electricity consumption of heating element | Drying function Settable temperature range | Filter | Material | Number of configurable phases | Number of driving programs | Power supply | Temperature accuracy | Temperature sensor | Water supply and drainage connection pipe diameter | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OSK50TH GW6010L |
Available upon quote | 1.0kW | 280L | 5℃~95℃ | Cleaning water volume: 18-23L for each phase Pump flow rate: 600 L/min | Water type (cold, hot, demineralized), amount of detergent, target temperature for the cleaning phase, phase elapsed time, drying set time, elapsed drying time | 1 peristaltic pump for injecting alkaline detergent, 1 peristaltic pump for injecting acidic neutralizer, peristaltic pump for additive injection (optional), dosing volume sensor for peristaltic pump (optional), flow meter for detergent volume measurement (high accuracy option) | External dimensions 650 x 720 x 1,950; Internal dimensions 550 x 620 x 685 | Multilingual/color compatible touch panel TFT-4.3 inches, installed on the loading side (installed on both loading and unloading sides for double-door type only) | Temperature, set time, remaining time, A0 value, ongoing phase, selected program, clock, calendar, report, warning code, maintenance | Both doors (two-sided open type) | C-class pre-filter 98% retention or S-class HEPA filter 99.99% retention (optional) | 220 m3/h | 3.6kW | 50÷110℃ |
Equipped with triple filters in the cleaning chamber (main filter, 3 types of micro filters, cleaning circuit protection filter) Microfilter for cold water injection pipe, hot water injection pipe, pure water injection pipe |
External panel: AISI 304 stainless steel Cleaning tank: AISI 316L stainless steel |
10 (washing/rinsing) +1 (drying) in 1 program | 40 (20 already set + 20 for arbitrary settings) | Three-phase 3/N/PE 400 V – 50 Hz – Power consumption up to 13 kW | 0.1℃ | Cleaning PT1000 Temperature Probe – IEC 60751, B Class | 3/4” DN20 | 280Kg | |
OSK50TH GW6010M |
Available upon quote | 1.0kW | 280L | 5℃~95℃ | Cleaning water volume: 18-23L for each phase Pump flow rate: 600 L/min | Water type (cold, hot, demineralized), amount of detergent, target temperature for the cleaning phase, phase elapsed time, drying set time, elapsed drying time | 1 peristaltic pump for injecting alkaline detergent, 1 peristaltic pump for injecting acidic neutralizer, peristaltic pump for additive injection (optional), dosing volume sensor for peristaltic pump (optional), flow meter for detergent volume measurement (high accuracy option) | External dimensions 650 x 720 x 1,950; Internal dimensions 550 x 620 x 685 | Multilingual/color compatible touch panel TFT-4.3 inches, installed on the loading side (installed on both loading and unloading sides for double-door type only) | Temperature, set time, remaining time, A0 value, ongoing phase, selected program, clock, calendar, report, warning code, maintenance | Single door (one side open type) | C-class pre-filter 98% retention or S-class HEPA filter 99.99% retention (optional) | 220 m3/h | 3.6kW | 50÷110℃ |
Equipped with triple filters in the cleaning chamber (main filter, 3 types of micro filters, cleaning circuit protection filter) Microfilter for cold water injection pipe, hot water injection pipe, pure water injection pipe |
External panel: AISI 304 stainless steel Cleaning tank: AISI 316L stainless steel |
10 (washing/rinsing) +1 (drying) in 1 program | 40 (20 already set + 20 for arbitrary settings) | Three-phase 3/N/PE 400 V – 50 Hz – Power consumption up to 13 kW | 0.1℃ | Cleaning PT1000 Temperature Probe – IEC 60751, B Class | 3/4” DN20 | 280Kg | |
OSK50TH GW6010T |
Available upon quote | 1.0kW | 280L | 5℃~95℃ | Cleaning water volume: 18-23L for each phase Pump flow rate: 600 L/min | Water type (cold, hot, demineralized), amount of detergent, target temperature for the cleaning phase, phase elapsed time, drying set time, elapsed drying time | 1 peristaltic pump for injecting alkaline detergent, 1 peristaltic pump for injecting acidic neutralizer, peristaltic pump for additive injection (optional), dosing volume sensor for peristaltic pump (optional), flow meter for detergent volume measurement (high accuracy option) | External dimensions 650 x 720 x 1,950; Internal dimensions 550 x 620 x 685 | Multilingual/color compatible touch panel TFT-4.3 inches, installed on the loading side (installed on both loading and unloading sides for double-door type only) | Temperature, set time, remaining time, A0 value, ongoing phase, selected program, clock, calendar, report, warning code, maintenance | Double door high speed circulation type | C-class pre-filter 98% retention or S-class HEPA filter 99.99% retention (optional) | 220 m3/h | 3.6kW | 50÷110℃ |
Equipped with triple filters in the cleaning chamber (main filter, 3 types of micro filters, cleaning circuit protection filter) Microfilter for cold water injection pipe, hot water injection pipe, pure water injection pipe |
External panel: AISI 304 stainless steel Cleaning tank: AISI 316L stainless steel |
10 (washing/rinsing) +1 (drying) in 1 program | 40 (20 already set + 20 for arbitrary settings) | Three-phase 3/N/PE 400 V – 50 Hz – Power consumption up to 13 kW | 0.1℃ | Cleaning PT1000 Temperature Probe – IEC 60751, B Class | 3/4” DN20 | 280Kg | |
OSK50TH GW6010TM |
Available upon quote | 1.0kW | 280L | 5℃~95℃ | Cleaning water volume: 18-23L for each phase Pump flow rate: 600 L/min | Water type (cold, hot, demineralized), amount of detergent, target temperature for the cleaning phase, phase elapsed time, drying set time, elapsed drying time | 1 peristaltic pump for injecting alkaline detergent, 1 peristaltic pump for injecting acidic neutralizer, peristaltic pump for additive injection (optional), dosing volume sensor for peristaltic pump (optional), flow meter for detergent volume measurement (high accuracy option) | External dimensions 650 x 720 x 1,950; Internal dimensions 550 x 620 x 685 | Multilingual/color compatible touch panel TFT-4.3 inches, installed on the loading side (installed on both loading and unloading sides for double-door type only) | Temperature, set time, remaining time, A0 value, ongoing phase, selected program, clock, calendar, report, warning code, maintenance | Single door high speed circulation type | C-class pre-filter 98% retention or S-class HEPA filter 99.99% retention (optional) | 220 m3/h | 3.6kW | 50÷110℃ |
Equipped with triple filters in the cleaning chamber (main filter, 3 types of micro filters, cleaning circuit protection filter) Microfilter for cold water injection pipe, hot water injection pipe, pure water injection pipe |
External panel: AISI 304 stainless steel Cleaning tank: AISI 316L stainless steel |
10 (washing/rinsing) +1 (drying) in 1 program | 40 (20 already set + 20 for arbitrary settings) | Three-phase 3/N/PE 400 V – 50 Hz – Power consumption up to 13 kW | 0.1℃ | Cleaning PT1000 Temperature Probe – IEC 60751, B Class | 3/4” DN20 | 280Kg | |
OSK50TH GW6010LX |
Available upon quote | 1.0kW | 280L | 5℃~95℃ | Cleaning water volume: 18-23L for each phase Pump flow rate: 600 L/min | Water type (cold, hot, demineralized), amount of detergent, target temperature for the cleaning phase, phase elapsed time, drying set time, elapsed drying time | 1 peristaltic pump for injecting alkaline detergent, 1 peristaltic pump for injecting acidic neutralizer, peristaltic pump for additive injection (optional), dosing volume sensor for peristaltic pump (optional), flow meter for detergent volume measurement (high accuracy option) | External dimensions 650 x 720 x 1,950; Internal dimensions 550 x 620 x 685 | Multilingual/color compatible touch panel TFT-4.3 inches, installed on the loading side (installed on both loading and unloading sides for double-door type only) | Temperature, set time, remaining time, A0 value, ongoing phase, selected program, clock, calendar, report, warning code, maintenance | Stainless steel double doors (no glass) | C-class pre-filter 98% retention or S-class HEPA filter 99.99% retention (optional) | 220 m3/h | 3.6kW | 50÷110℃ |
Equipped with triple filters in the cleaning chamber (main filter, 3 types of micro filters, cleaning circuit protection filter) Microfilter for cold water injection pipe, hot water injection pipe, pure water injection pipe |
External panel: AISI 304 stainless steel Cleaning tank: AISI 316L stainless steel |
10 (washing/rinsing) +1 (drying) in 1 program | 40 (20 already set + 20 for arbitrary settings) | Three-phase 3/N/PE 400 V – 50 Hz – Power consumption up to 13 kW | 0.1℃ | Cleaning PT1000 Temperature Probe – IEC 60751, B Class | 3/4” DN20 | 280Kg | |
OSK50TH GW6010ML |
Available upon quote | 1.0kW | 280L | 5℃~95℃ | Cleaning water volume: 18-23L for each phase Pump flow rate: 600 L/min | Water type (cold, hot, demineralized), amount of detergent, target temperature for the cleaning phase, phase elapsed time, drying set time, elapsed drying time | 1 peristaltic pump for injecting alkaline detergent, 1 peristaltic pump for injecting acidic neutralizer, peristaltic pump for additive injection (optional), dosing volume sensor for peristaltic pump (optional), flow meter for detergent volume measurement (high accuracy option) | External dimensions 650 x 720 x 1,950; Internal dimensions 550 x 620 x 685 | Multilingual/color compatible touch panel TFT-4.3 inches, installed on the loading side (installed on both loading and unloading sides for double-door type only) | Temperature, set time, remaining time, A0 value, ongoing phase, selected program, clock, calendar, report, warning code, maintenance | Single door R type insert compatible (no trolley required) | C-class pre-filter 98% retention or S-class HEPA filter 99.99% retention (optional) | 220 m3/h | 3.6kW | 50÷110℃ |
Equipped with triple filters in the cleaning chamber (main filter, 3 types of micro filters, cleaning circuit protection filter) Microfilter for cold water injection pipe, hot water injection pipe, pure water injection pipe |
External panel: AISI 304 stainless steel Cleaning tank: AISI 316L stainless steel |
10 (washing/rinsing) +1 (drying) in 1 program | 40 (20 already set + 20 for arbitrary settings) | Three-phase 3/N/PE 400 V – 50 Hz – Power consumption up to 13 kW | 0.1℃ | Cleaning PT1000 Temperature Probe – IEC 60751, B Class | 3/4” DN20 | 280Kg | |
OSK50TH GW6010MLX |
Available upon quote | 1.0kW | 280L | 5℃~95℃ | Cleaning water volume: 18-23L for each phase Pump flow rate: 600 L/min | Water type (cold, hot, demineralized), amount of detergent, target temperature for the cleaning phase, phase elapsed time, drying set time, elapsed drying time | 1 peristaltic pump for injecting alkaline detergent, 1 peristaltic pump for injecting acidic neutralizer, peristaltic pump for additive injection (optional), dosing volume sensor for peristaltic pump (optional), flow meter for detergent volume measurement (high accuracy option) | External dimensions 650 x 720 x 1,950; Internal dimensions 550 x 620 x 685 | Multilingual/color compatible touch panel TFT-4.3 inches, installed on the loading side (installed on both loading and unloading sides for double-door type only) | Temperature, set time, remaining time, A0 value, ongoing phase, selected program, clock, calendar, report, warning code, maintenance | Single door compatible with stainless steel R type insert (no trolley required) | C-class pre-filter 98% retention or S-class HEPA filter 99.99% retention (optional) | 220 m3/h | 3.6kW | 50÷110℃ |
Equipped with triple filters in the cleaning chamber (main filter, 3 types of micro filters, cleaning circuit protection filter) Microfilter for cold water injection pipe, hot water injection pipe, pure water injection pipe |
External panel: AISI 304 stainless steel Cleaning tank: AISI 316L stainless steel |
10 (washing/rinsing) +1 (drying) in 1 program | 40 (20 already set + 20 for arbitrary settings) | Three-phase 3/N/PE 400 V – 50 Hz – Power consumption up to 13 kW | 0.1℃ | Cleaning PT1000 Temperature Probe – IEC 60751, B Class | 3/4” DN20 | 280Kg |