All Categories

History

transformer adapter-AD06101-P
transformer adapter-Taisei Electronics Co., Ltd.

Taisei Electronics Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

8.9hours

Fast Response


About This Product

■Features

・High quality and safe made in Japan ・All transformer AC adapters are produced domestically. *Other model numbers are available.

  • Product

    transformer adapter

Share this product


580+ people viewing

Last viewed: 8 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of transformer adapter

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Overvoltage/undervoltage operation Withstand voltage Insulation resistance Temperature rise Consumption capacity Rated output Rating input Exterior Output voltage: At rated input and resistive load Operating temperature range Ripple voltage Cord tensile strength Standard
transformer adapter-Part Number-AD06101-P

AD06101-P

Available upon quote

No ignition or exposure of live parts by output short circuit test or operation at rated input voltage ±10%

No abnormality when applying 1,000V AC for 1 minute or 1,200V AC for 1 second between input and output (cutoff current 2mA)

Insulation resistance between input and output must be 100MΩ or more when measuring 500V DC.

The case surface temperature rise during rated input and rated load operation must be 40 degrees or less.

Must be 4VA or less at rated input and rated load

DC 6V 100mA

AC 100V 50/60Hz

No noticeable defects such as scratches, deformation, uneven coloring, etc.

No load: 8.6V±0.4V, DC100mA load: 6.0V±0.4V (Ambient temperature 25℃)

-10℃ ~ +40℃

Must be 300mV (R.M.S) or less at rated input and rated load.

The tensile strength between the main body and the DC cord can withstand 49N or more for 1 minute.

Must be compliant with the Electrical Appliance and Material Safety Law

transformer adapter-Part Number-AD06201-M

AD06201-M

Available upon quote

No ignition or exposure of live parts by output short circuit test or operation at rated input voltage ±10%

No abnormality when applying 1,000V AC for 1 minute or 1,200V AC for 1 second between input and output (cutoff current 2mA)

Insulation resistance between input and output must be 100MΩ or more when measuring 500V DC.

The case surface temperature rise during rated input and rated load operation must be 40 degrees or less.

Must be 5 VA or less at rated input and rated load.

DC 6V 200mA

AC 100V 50/60Hz

No noticeable defects such as scratches, deformation, uneven coloring, etc.

No load: 10.6V±0.4V, DC200mA load: 6.0V±0.4V (Ambient temperature 25℃)

-10℃ ~ +40℃

Must be 570mV (R.M.S) or less at rated input and rated load.

The tensile strength between the main body and the DC cord can withstand 49N or more for 1 minute.

Must be compliant with the Electrical Appliance and Material Safety Law

transformer adapter-Part Number-AD06301-P

AD06301-P

Available upon quote

No ignition or exposure of live parts by output short circuit test or operation at rated input voltage ±10%

No abnormality when applying 1,000V AC for 1 minute or 1,200V AC for 1 second between input and output (cutoff current 2mA)

Insulation resistance between input and output must be 100MΩ or more when measuring 500V DC.

The case surface temperature rise during rated input and rated load operation must be 40 degrees or less.

Must be 6VA or less at rated input and rated load

DC 6V 300mA

AC 100V 50/60Hz

No noticeable defects such as scratches, deformation, uneven coloring, etc.

No load: 8.8V±0.5V, DC300mA load: 6.0V±0.5V (Ambient temperature 25℃)

-10℃ ~ +40℃

Must be 350mV (R.M.S) or less at rated input and rated load.

The tensile strength between the main body and the DC cord can withstand 49N or more for 1 minute.

Must be compliant with the Electrical Appliance and Material Safety Law

transformer adapter-Part Number-AD06501-P

AD06501-P

Available upon quote

No ignition or exposure of live parts by output short circuit test or operation at rated input voltage ±10%

No abnormality when applying 1,000V AC for 1 minute or 1,200V AC for 1 second between input and output (cutoff current 2mA)

Insulation resistance between input and output must be 100MΩ or more when measuring 500V DC.

The case surface temperature rise during rated input and rated load operation must be 40 degrees or less.

Must be 8VA or less at rated input and rated load

DC 6V 500mA

AC 100V 50/60Hz

No noticeable defects such as scratches, deformation, uneven coloring, etc.

No load: 10.6V±0.5V, DC500mA load: 6.0V±0.5V (Ambient temperature 25℃)

-10℃ ~ +40℃

Must be 530mV (R.M.S) or less at rated input and rated load.

The tensile strength between the main body and the DC cord can withstand 49N or more for 1 minute.

Must be compliant with the Electrical Appliance and Material Safety Law

transformer adapter-Part Number-AD06801-P

AD06801-P

Available upon quote

No ignition or exposure of live parts by output short circuit test or operation at rated input voltage ±10%

No abnormality when applying 1,000V AC for 1 minute or 1,200V AC for 1 second between input and output (cutoff current 2mA)

Insulation resistance between input and output must be 100MΩ or more when measuring 500V DC.

The case surface temperature rise during rated input and rated load operation must be 40 degrees or less.

Must be 12 VA or less at rated input and rated load.

DC 6V 800mA

AC 100V 50/60Hz

No noticeable defects such as scratches, deformation, uneven coloring, etc.

No load: 9.7V±0.4V, DC800mA load: 6.0V±0.4V (Ambient temperature 25℃)

-10℃ ~ +40℃

Must be 590mV (R.M.S) or less at rated input and rated load.

The tensile strength between the main body and the DC cord can withstand 49N or more for 1 minute.

Must be compliant with the Electrical Appliance and Material Safety Law

transformer adapter-Part Number-AD06102-P

AD06102-P

Available upon quote

No ignition or exposure of live parts by output short circuit test or operation at rated input voltage ±10%

No abnormality when applying 1,000V AC for 1 minute or 1,200V AC for 1 second between input and output (cutoff current 2mA)

Insulation resistance between input and output must be 100MΩ or more when measuring 500V DC.

The case surface temperature rise during rated input and rated load operation must be 40 degrees or less.

Must be 14VA or less at rated input and rated load

DC 6V 1,000mA

AC 100V 50/60Hz

No noticeable defects such as scratches, deformation, uneven coloring, etc.

No load: 9.1V±0.5V, DC1,000mA load: 6.0V±0.5V (Ambient temperature 25℃)

-10℃ ~ +40℃

Must be 490mV (R.M.S) or less at rated input and rated load.

The tensile strength between the main body and the DC cord can withstand 49N or more for 1 minute.

Must be compliant with the Electrical Appliance and Material Safety Law

transformer adapter-Part Number-AD09101-P

AD09101-P

Available upon quote

No ignition or exposure of live parts by output short circuit test or operation at rated input voltage ±10%

No abnormality when applying 1,000V AC for 1 minute or 1,200V AC for 1 second between input and output (cutoff current 2mA)

Insulation resistance between input and output must be 100MΩ or more when measuring 500V DC.

The case surface temperature rise during rated input and rated load operation must be 40 degrees or less.

Must be 5 VA or less at rated input and rated load.

DC 9V 100mA

AC 100V 50/60Hz

No noticeable defects such as scratches, deformation, uneven coloring, etc.

No load: 12.9V±0.6V, DC100mA load: 9.0V±0.6V (Ambient temperature 25℃)

-10℃ ~ +40℃

Must be 300mV (R.M.S) or less at rated input and rated load.

The tensile strength between the main body and the DC cord can withstand 49N or more for 1 minute.

Must be compliant with the Electrical Appliance and Material Safety Law

transformer adapter-Part Number-AD09201-P

AD09201-P

Available upon quote

No ignition or exposure of live parts by output short circuit test or operation at rated input voltage ±10%

No abnormality when applying 1,000V AC for 1 minute or 1,200V AC for 1 second between input and output (cutoff current 2mA)

Insulation resistance between input and output must be 100MΩ or more when measuring 500V DC.

The case surface temperature rise during rated input and rated load operation must be 40 degrees or less.

Must be 7VA or less at rated input and rated load

DC 9V 200mA

AC 100V 50/60Hz

No noticeable defects such as scratches, deformation, uneven coloring, etc.

No load: 12.7V±0.6V, DC100mA load: 9.0V±0.6V (Ambient temperature 25℃)

-10℃ ~ +40℃

Must be 570mV (R.M.S) or less at rated input and rated load.

The tensile strength between the main body and the DC cord can withstand 49N or more for 1 minute.

Must be compliant with the Electrical Appliance and Material Safety Law

transformer adapter-Part Number-AD09301-P

AD09301-P

Available upon quote

No ignition or exposure of live parts by output short circuit test or operation at rated input voltage ±10%

No abnormality when applying 1,000V AC for 1 minute or 1,200V AC for 1 second between input and output (cutoff current 2mA)

Insulation resistance between input and output must be 100MΩ or more when measuring 500V DC.

The case surface temperature rise during rated input and rated load operation must be 40 degrees or less.

Must be 7VA or less at rated input and rated load

DC 9V 300mA

AC 100V 50/60Hz

No noticeable defects such as scratches, deformation, uneven coloring, etc.

No load: 14.1V±0.7V, DC300mA load: 9.0V±0.7V (Ambient temperature 25℃)

-10℃ ~ +40℃

Must be 840mV (R.M.S) or less at rated input and rated load.

The tensile strength between the main body and the DC cord can withstand 49N or more for 1 minute.

Must be compliant with the Electrical Appliance and Material Safety Law

transformer adapter-Part Number-AD09501-P

AD09501-P

Available upon quote

No ignition or exposure of live parts by output short circuit test or operation at rated input voltage ±10%

No abnormality when applying 1,000V AC for 1 minute or 1,200V AC for 1 second between input and output (cutoff current 2mA)

Insulation resistance between input and output must be 100MΩ or more when measuring 500V DC.

The case surface temperature rise during rated input and rated load operation must be 40 degrees or less.

Must be 11 VA or less at rated input and rated load.

DC 9V 500mA

AC 100V 50/60Hz

No noticeable defects such as scratches, deformation, uneven coloring, etc.

No load: 14.2V±0.7V, DC500mA load: 9.0V±0.7V (Ambient temperature 25℃)

-10℃ ~ +40℃

Must be 530mV (R.M.S) or less at rated input and rated load.

The tensile strength between the main body and the DC cord can withstand 49N or more for 1 minute.

Must be compliant with the Electrical Appliance and Material Safety Law

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More AC Adapters Products

Other products of Taisei Electronics Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Taisei Electronics Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

8.9hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree