Product
Airborne particle counter Real time REMOTE Remote RS-485 Modbus communicationHandling Company
SGY Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accessories | Air flow | Calibration | Communication mode | Connector | Counting efficiency | Data storage | Environmental conditions Operating environment | Environmental conditions Storage environment | Environmental sensor | Housing | LED warning light | Laser light source | Maximum particle concentration | Measure particle size | Optional counting channel | Output to external alarm | Power supply | Sampling flow rate | Standard counting channel | Support software | Vacuum source | Zero Count Level (false count) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Remote 2014 |
Available upon quote | CD operation manual | Monitor internally | NIST traceable | RS-485 MODBUS | RJ45 |
50% at 0.2μm, 100% at 0.3μm or more (ISO 21501-4 compliant) |
Rotating buffer, 2,000 records | 50°F~104°F (10°C~40°C) / 20%~95% non-condensing | 14°F~122°F (-10°C~50°C) / up to 98% non-condensing |
(Optional) Temperature/humidity probe 32°F~122°F±1F (0℃~50℃±0.5℃) 0~100%RH±2% |
Stainless steel | Power, Flow, Service, Sampling | Laser diode | 2 million particles/ft³ @ 5% coincidence loss | 0.2~2.0μm |
0.2/0.3/0.5/1.0μm (4ch) 0.2/0.3/0.5/2.0μm (4ch) |
Normally open, dry contact, rated 0-60 VDC/VAC, 1Amp | 24 VDC | 0.1 CFM (2.83 ℓ/min) |
0.2/0.3μm (2ch) 0.2/0.5μm (2ch) |
LMS XChange, Lighthouse Monitoring System, LMS Express RT, LMSNet | External vacuum source required, 18" (45.72cm) Hg or higher | <1 count/5 minutes (ISO 21501-4 compliant) | |
Remote 3014 |
Available upon quote | CD operation manual | Monitor internally | NIST traceable | RS-485 MODBUS | RJ45 |
50% at 0.3μm, 100% at 0.45μm or more (ISO 21501-4 compliant) |
Rotating buffer, 2,000 records | 50°F~104°F (10°C~40°C) / 20%~95% non-condensing | 14°F~122°F (-10°C~50°C) / up to 98% non-condensing |
(Optional) Temperature/humidity probe 32°F~122°F±1F (0℃~50℃±0.5℃) 0~100%RH±2% |
Stainless steel | Power, Flow, Service, Sampling | Laser diode | 2 million particles/ft³ @ 5% coincidence loss | 0.3~25.0μm | 0.3/0.5/1.0/5.0μm (4ch) | Normally open, dry contact, rated 0-60 VDC/VAC, 1Amp | 24 VDC | 0.1 CFM (2.83 ℓ/min) |
0.3/0.5μm (2ch) 0.3/1.0μm (2ch) 0.3/3.0μm (2ch) |
LMS XChange, Lighthouse Monitoring System, LMS Express RT, LMSNet | External vacuum source required, 18" (45.72cm) Hg or higher | <1 count/5 minutes (ISO 21501-4 compliant) | |
Remote 5014 |
Available upon quote | CD operation manual | Monitor internally | NIST traceable | RS-485 MODBUS | RJ45 |
50% at 0.5μm, 100% at 0.75μm or more (ISO 21501-4 compliant) |
Rotating buffer, 2,000 records | 50°F~104°F (10°C~40°C) / 20%~95% non-condensing | 14°F~122°F (-10°C~50°C) / up to 98% non-condensing |
(Optional) Temperature/humidity probe 32°F~122°F±1F (0℃~50℃±0.5℃) 0~100%RH±2% |
Stainless steel | Power, Flow, Service, Sampling | Laser diode | 2 million particles/ft³ @ 5% coincidence loss | 0.5~25.0μm |
0.5/1.0/5.0/10.0μm (4ch) 0.5/5.0/10.0/25.0μm (4ch) |
Normally open, dry contact, rated 0-60 VDC/VAC, 1Amp | 24 VDC | 0.1 CFM (2.83 ℓ/min) | 0.5/5.0μm (2ch) | LMS XChange, Lighthouse Monitoring System, LMS Express RT, LMSNet | External vacuum source required, 18" (45.72cm) Hg or higher | <1 count/5 minutes (ISO 21501-4 compliant) |