Airborne particle counter portable type low flow rate SOLAIR-Solair 1100LD
Airborne particle counter portable type low flow rate SOLAIR-Solair 3100
Airborne particle counter portable type low flow rate SOLAIR-Solair 5100
Airborne particle counter portable type low flow rate SOLAIR-Solair Boulder
Airborne particle counter portable type low flow rate SOLAIR-SGY Co., Ltd.

Airborne particle counter portable type low flow rate SOLAIR
SGY Co., Ltd.


About This Product

■SOLAIR model with sampling flow rate 1CFM (28,3ℓ/min) -We have models with the minimum particle size that can be counted: 0.1μm, 0.2μm, 0.3μm, 0.5μm, and 5.0μm. ・Several languages ​​can be selected for the touch screen display in addition to English and Japanese. Equipped with our special long-life laser diode technology sensor, which has achieved the industry's longest laser diode life with an MTTF (Mean Time To Failure) of over 20 years based on 24-hour continuous measurement. ・The minimum particle size for measurement is 0.1μm, 0.3μm, 0.5μm, and 5.0μm, and the sampling flow rate is SOLAIR of 28.3ℓ/min. - A user interface that allows you to easily and intuitively understand sampling settings just by looking at it, with a concise layout and highly responsive icon menu system that could only be achieved by a manufacturer that specializes in software.

  • Product

    Airborne particle counter portable type low flow rate SOLAIR

Share this product


190+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

4 Models of Airborne particle counter portable type low flow rate SOLAIR

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Alarm Analog input Battery Calibration Communication mode Counting efficiency Counting mode Data storage Display language Environmental conditions Operating environment Environmental conditions Storage environment Environmental sensor Housing Laser light source Location label Maximum particle concentration Measure particle size Optional counting channel Power supply Printer Report Sample air exhaust Sampling flow rate Support software Touch screen Vacuum source Weight Zero Count Level (false count)
Airborne particle counter portable type low flow rate SOLAIR-Part Number-Solair 1100LD

Solair 1100LD

Available upon quote Built-in adjustable alarm and connector to external alarm; counting alarm, low battery alarm or sensor abnormality Up to 4 environmental sensors (temperature/humidity/air velocity/differential pressure) can be input with 4-20mA signals Optional removable and rechargeable lithium-ion battery Meets ISO 21501-4 calibration using NIST traceable PSL spheres USB, Ethernet, RS-485, USB memory 50% at 0.1μm, 100% at 0.15μm or more (ISO 21501-4 compliant) Automatic, manual, beep, concentration, cumulative/differential, real-time (using LMS software) 3,000 sample records, Rotating buffer, particle and environment data, position and time Japanese, English (American), Korean, Chinese, German, Spanish, Italian, French, Russian, (*Firmware for Asia consists of the four languages ​​listed in blue above.) 50°F~104°F (10°C~40°C) / 20%~95% non-condensing 14°F~122°F (-10°C~50°C) / up to 98% non-condensing Direct-mount temperature probe: 0-150°F (-17.8~65.6°C) ±1.8°F @ 77°F
Direct-mount relative humidity probe: 0-100% ± 5% @ 33%
Stainless steel Long life laser diode Up to 200 location labels Million particles/ft³ (34.3 million/m3) @ 10% coincidence loss 0.1~1.0 (5.0) μm 0.1/0.15/0.2/0.25/0.3/0.5/1.0/5.0μm (8ch) 100-240VAC 50/60Hz, external AC/DC adapter Built-in thermal printer (optional) FS-209, ISO-14644-1:2015, ISO-14644-1:999, EC GMP Annex 1 Built-in ULPA filter for exhaust, HEPA filter can be installed on the exhaust port as an option 1.0 CFM (28.3 ℓ/min) LMS Express, LMS Express RT, LMS Pharma, LMS Pro 5.7” (14.47 cm), color TFT touchscreen display Built-in pump, automatic flow control Without battery: 20.25lbs (9.19Kg)
With battery: 23.35lbs (10.6Kg)
<1 count/5 minutes (ISO 21501-4 compliant)
Airborne particle counter portable type low flow rate SOLAIR-Part Number-Solair 3100

Solair 3100

Available upon quote Built-in adjustable alarm and connector to external alarm; counting alarm, low battery alarm or sensor abnormality Up to 4 environmental sensors (temperature/humidity/air velocity/differential pressure) can be input with 4-20mA signals Optional removable and rechargeable lithium-ion battery Meets ISO 21501-4 calibration using NIST traceable PSL spheres USB, Ethernet, RS-485, USB memory 50% at 0.3μm, 100% at 0.45μm or more (ISO 21501-4 compliant) Automatic, manual, beep, concentration, cumulative/differential, real-time (using LMS software) 3,000 sample records, Rotating buffer, particle and environment data, position and time Japanese, English (American), Korean, Chinese, German, Spanish, Italian, French, Russian, (*Firmware for Asia consists of the four languages ​​listed in blue above.) 50°F~104°F (10°C~40°C) / 20%~95% non-condensing 14°F~122°F (-10°C~50°C) / up to 98% non-condensing Direct-mount temperature probe: 0-150°F (-17.8~65.6°C) ±1.8°F @ 77°F
Direct-mount relative humidity probe: 0-100% ± 5% @ 33%
Stainless steel Ultra-long life laser diode with MTTF (mean time to failure) of over 20 years Up to 200 location labels Million particles/ft³ (35.3 million/m3) @ 10% coin density loss, suitable for ISO class 1-8 cleanrooms 0.3~25.0μm - 100-250VAC 47-63Hz Built-in thermal printer (optional) FS-209, ISO-14644-1:2015, ISO-14644-1:999, EC GMP Annex 1 Built-in filter meets HEPA standards (>99.97% @ 0.3 μm) 1.0 CFM (28.3 ℓ/min) LMS Express, LMS Express RT, LMS Pharma, LMS Pro 5.7” (14.47 cm), color TFT touchscreen display Pump with internal closed loop control Without battery: 12.35 lbs (5.6Kg)
With battery: 13.95lbs (6.33Kg)
<1 count/5 minutes (ISO 21501-4 compliant)
Airborne particle counter portable type low flow rate SOLAIR-Part Number-Solair 5100

Solair 5100

Available upon quote Built-in adjustable alarm and connector to external alarm; counting alarm, low battery alarm or sensor abnormality Up to 4 environmental sensors (temperature/humidity/air velocity/differential pressure) can be input with 4-20mA signals Optional removable and rechargeable lithium-ion battery Meets ISO 21501-4 calibration using NIST traceable PSL spheres USB, Ethernet, RS-485, USB memory 50% at 0.5μm, 100% at 0.75μm or more (ISO 21501-4 compliant) Automatic, manual, beep, concentration, cumulative/differential, real-time (using LMS software) 3,000 sample records, Rotating buffer, particle and environment data, position and time Japanese, English (American), Korean, Chinese, German, Spanish, Italian, French, Russian, (*Firmware for Asia consists of the four languages ​​listed in blue above.) 50°F~104°F (10°C~40°C) / 20%~95% non-condensing 14°F~122°F (-10°C~50°C) / up to 98% non-condensing Direct-mount temperature probe: 0-150°F (-17.8~65.6°C) ±1.8°F @ 77°F
Direct-mount relative humidity probe: 0-100% ± 5% @ 33%
Stainless steel Ultra-long life laser diode with MTTF (mean time to failure) of over 20 years Up to 200 location labels Million particles/ft³ (35.3 million/m3) @ 10% coin density loss, suitable for ISO class 1-8 cleanrooms 0.5~25.0μm - 100-250VAC 47-63Hz Built-in thermal printer (optional) FS-209, ISO-14644-1:2015, ISO-14644-1:999, EC GMP Annex 1 Built-in filter meets HEPA standards (>99.97% @ 0.3 μm) 1.0 CFM (28.3 ℓ/min) LMS Express, LMS Express RT, LMS Pharma, LMS Pro 5.7” (14.47 cm), color TFT touchscreen display Pump with internal closed loop control Without battery: 12.35 lbs (5.6Kg)
With battery: 13.95lbs (6.33Kg)
<1 count/5 minutes (ISO 21501-4 compliant)
Airborne particle counter portable type low flow rate SOLAIR-Part Number-Solair Boulder

Solair Boulder

Available upon quote Built-in adjustable alarm and connector to external alarm; counting alarm, low battery alarm or sensor abnormality Up to 4 environmental sensors (temperature/humidity/air velocity/differential pressure) can be input with 4-20mA signals Optional removable and rechargeable lithium-ion battery Meets ISO 21501-4 calibration using NIST traceable PSL spheres USB, Ethernet, RS-485, USB memory 50% at 5.0μm (according to ISO 21501-4) Automatic, manual, beep, concentration, cumulative/differential, real-time (using LMS software) 3,000 sample records, Rotating buffer, particle and environment data, position and time Japanese, English (American), Korean, Chinese, German, Spanish, Italian, French, Russian, (*Firmware for Asia consists of the four languages ​​listed in blue above.) 50°F~104°F (10°C~40°C) / 20%~95% non-condensing 14°F~122°F (-10°C~50°C) / up to 98% non-condensing Direct-mount temperature probe: 0-150°F (-17.8~65.6°C) ±1.8°F @ 77°F
Direct-mount relative humidity probe: 0-100% ± 5% @ 33%
Stainless steel Ultra-long life laser diode with MTTF (mean time to failure) of over 20 years Up to 200 location labels Million particles/ft³ (35.3 million/m3) @ 10% coin density loss 5.0~100.0μm 5.0/10.0/20.0/30.0/50.0/100.0μm (6ch) 100-250VAC 47-63Hz Built-in thermal printer (optional) FS-209, ISO-14644-1:2015, ISO-14644-1:999, EC GMP Annex 1 Built-in filter meets HEPA standards (>99.97% @ 0.3 μm) 1.0 CFM (28.3 ℓ/min) LMS Express, LMS Express RT, LMS Pharma, LMS Pro 5.7” (14.47 cm), color TFT touchscreen display Pump with internal closed loop control Without battery: 12.35 lbs (5.6Kg)
With battery: 13.95lbs (6.33Kg)
<1 count/5 minutes (ISO 21501-4 compliant)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of SGY Co., Ltd.


View more products of SGY Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree