■HANDHELD Handheld type portable airborne particle counter -Handheld type that can be held with one hand and easily operated. ・Sampling flow rate is 0.1CFM (2.83ℓ/min). -We have models with the minimum particle size that can be counted: 0.2μm, 0.3μm, and 0.5μm. ・Several languages ​​can be selected for the touch screen display in addition to English and Japanese. -This handheld particle counter is a lightweight and highly operable mobile particle counter that incorporates ergonomics into its design so that it can be used in places where it cannot be operated with both hands. - It has 6 channels that can simultaneously count particles of different sizes (3013 is standard 3 channels), and can also measure temperature and humidity at the same time (3013 is excluded). - Accumulated particle count data, differential data, temperature and humidity data can be displayed on the easy-to-read touch screen, and the data can be transferred from the USB port for the 3013 and the RJ-45 communication port for other models. - Equipped with a removable (fixed for 3013) rechargeable lithium-ion battery, allowing long-time use. The 3016-IAQ can also measure mass concentration (μg/㎥).

  • Product

    Airborne particle counter portable type HANDHELD

Share this product


260+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

4 Models of Airborne particle counter portable type HANDHELD

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Alarm Battery Calibration Communication mode Counting efficiency Counting mode Data storage Display language Environmental conditions Operating environment Environmental conditions Storage environment Environmental sensor Housing Laser light source Mass concentration Maximum particle concentration Measure particle size Optional counting channel (6ch) Power supply Report Sample flow rate Sample inlet Sample output Standard counting channels (3ch, 6ch) Support software Touch screen Vacuum source Weight Zero Count Level (false count)
Airborne particle counter portable type HANDHELD-Part Number-Handheld 2016

Handheld 2016

Available upon quote Built-in adjustable alarm buzzer, counting alarm, low battery alarm or sensor abnormality Lithium-ion, removable and rechargeable Meets ISO 21501-4 calibration using NIST traceable PSL spheres, DMA and condensation particle counters Communication port RJ-45 to RS-232 to PC or optional printer 50% at 0.2μm, 100% at 0.3μm or more (ISO 21501-4 compliant) Automatic, manual, beep alarm, concentration, cumulative/differential 3,000 sample records, Rotating buffer, particle and environment data, position and time Japanese, English (American), Korean, Chinese, German, Spanish, Italian, French, Russian, (*Firmware for Asia consists of the four languages ​​listed in blue above.) 50°F~104°F (10°C~40°C) / 20%~95% non-condensing 14°F~122°F (-10°C~50°C) / up to 98% non-condensing Direct-mount temperature probe: 0-150°F (-17.8~65.6°C) ±1.8°F @ 77°F
Direct-mount relative humidity probe: 0-100% ± 5% @ 33%
High impact injection molded plastic Ultra-long life laser diode with MTTF (mean time to failure) of over 20 years - 4,000,000 particles/ft³ @coincidence loss 0.2~2.0μm - From external power supply: 12VDC, 1.25A FS-209E, ISO-14644-1, EC GMP 0.1 CFM (2.83ℓ/min) Isokinetic sample probe Meets HEPA standards (> 99.97% @ 0.3 μm) through built-in filter 0.2/0.3/0.5/0.7/1.0/2.0μm LMS Express, LMS Express RT, LMS Pharma, LMS Pro 3.5” (8.89 cm), color TFT Built-in pump, automatic flow control 2.2lbs (1Kg) <1 count/5 minutes (per ISO 21501-4)
Airborne particle counter portable type HANDHELD-Part Number-Handheld 3016

Handheld 3016

Available upon quote Built-in adjustable alarm buzzer, counting alarm, low battery alarm or sensor abnormality Lithium-ion, removable and rechargeable Meets ISO 21501-4 calibration using NIST traceable PSL spheres, DMA and condensation particle counters Communication port RJ-45 to RS-232 to PC or optional printer 50% at 0.3μm, 100% at 0.45μm or more (ISO 21501-4 compliant) Automatic, manual, beep alarm, concentration, cumulative/differential 3,000 sample records, Rotating buffer, particle and environment data, position and time Japanese, English (American), Korean, Chinese, German, Spanish, Italian, French, Russian, (*Firmware for Asia consists of the four languages ​​listed in blue above.) 50°F~104°F (10°C~40°C) / 20%~95% non-condensing 14°F~122°F (-10°C~50°C) / up to 98% non-condensing Direct-mount temperature probe: 0-150°F (-17.8~65.6°C) ±1.8°F @ 77°F
Direct-mount relative humidity probe: 0-100% ± 5% @ 33%
High impact injection molded plastic Ultra-long life laser diode with MTTF (mean time to failure) of over 20 years - 4,000,000 particles/ft³ @coincidence loss 0.3~25.0μm 0.3/0.5/1.0/5.0/10.0/25.0μm From external power supply: 12VDC, 1.25A FS-209E, ISO-14644-1, EC GMP 0.1 CFM (2.83ℓ/min) Isokinetic sample probe Meets HEPA standards (> 99.97% @ 0.3 μm) through built-in filter - LMS Express, LMS Express RT, LMS Pharma, LMS Pro 3.5” (8.89 cm), color TFT Built-in pump, automatic flow control 2.2lbs (1Kg) <1 count/5 minutes (per ISO 21501-4)
Airborne particle counter portable type HANDHELD-Part Number-Handheld 5016

Handheld 5016

Available upon quote Built-in adjustable alarm buzzer, counting alarm, low battery alarm or sensor abnormality Lithium-ion, removable and rechargeable Meets ISO 21501-4 calibration using NIST traceable PSL spheres, DMA and condensation particle counters Communication port RJ-45 to RS-232 to PC or optional printer 50% at 0.5μm, 100% at 0.75μm or more (ISO 21501-4 compliant) Automatic, manual, beep alarm, concentration, cumulative/differential 3,000 sample records, Rotating buffer, particle and environment data, position and time Japanese, English (American), Korean, Chinese, German, Spanish, Italian, French, Russian, (*Firmware for Asia consists of the four languages ​​listed in blue above.) 50°F~104°F (10°C~40°C) / 20%~95% non-condensing 14°F~122°F (-10°C~50°C) / up to 98% non-condensing Direct-mount temperature probe: 0-150°F (-17.8~65.6°C) ±1.8°F @ 77°F
Direct-mount relative humidity probe: 0-100% ± 5% @ 33%
High impact injection molded plastic Ultra-long life laser diode with MTTF (mean time to failure) of over 20 years - 4,000,000 particles/ft³ @coincidence loss 0.5~25.0μm 0.5/1.0/3.0/5.0/10.0/25.0μm From external power supply: 12VDC, 1.25A FS-209E, ISO-14644-1, EC GMP 0.1 CFM (2.83ℓ/min) Isokinetic sample probe Meets HEPA standards (> 99.97% @ 0.3 μm) through built-in filter 0.5/0.7/1.0/3.0/5.0/10.0μm LMS Express, LMS Express RT, LMS Pharma, LMS Pro 3.5” (8.89 cm), color TFT Built-in pump, automatic flow control 2.2lbs (1Kg) <1 count/5 minutes (per ISO 21501-4)
Airborne particle counter portable type HANDHELD-Part Number-Handheld 3016-IAQ

Handheld 3016-IAQ

Available upon quote Built-in adjustable alarm buzzer, counting alarm, low battery alarm or sensor abnormality Lithium-ion, removable and rechargeable Meets ISO 21501-4 calibration using NIST traceable PSL spheres, DMA and condensation particle counters Communication port RJ-45 to RS-232 to PC or optional printer 50% at 0.3μm, 100% at 0.45μm or more (ISO 21501-4 compliant) Automatic, manual, beep alarm, concentration, cumulative/difference, mass concentration 3,000 sample records, Rotating buffer, particle and environment data, position and time Japanese, English (American), Korean, Chinese, German, Spanish, Italian, French, Russian, (*Firmware for Asia consists of the four languages ​​listed in blue above.) 50°F~104°F (10°C~40°C) / 20%~95% non-condensing 14°F~122°F (-10°C~50°C) / up to 98% non-condensing Direct-mount temperature probe: 0-150°F (-17.8~65.6°C) ±1.8°F @ 77°F
Direct-mount relative humidity probe: 0-100% ± 5% @ 33%
High impact injection molded plastic Ultra-long life laser diode with MTTF (mean time to failure) of over 20 years 1μg/m3 approximate mass concentration 4,000,000 particles/ft³ @coincidence loss 0.3~10.0μm - From external power supply: 12VDC, 1.25A FS-209E, ISO-14644-1, EC GMP 0.1 CFM (2.83ℓ/min) Isokinetic sample probe Meets HEPA standards (> 99.97% @ 0.3 μm) through built-in filter 0.3/0.5/1.0/2.5/5.0/10.0μm LMS Express, LMS Express RT, LMS Pharma, LMS Pro 3.5” (8.89 cm), color TFT Built-in pump, automatic flow control 2.2lbs (1Kg) <1 count/5 minutes (per ISO 21501-4)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of SGY Co., Ltd.


View more products of SGY Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree