DC ammeter PSA-2401-PSA-2401 ±20mA type
DC ammeter PSA-2401-Coco Research Co., Ltd.

DC ammeter PSA-2401
Coco Research Co., Ltd.


About This Product

■Summary Accurately responds to rapid fluctuations with breakthrough speed. Achieved a 40mΩ shunt for PWM current/charging current measurement. ■Features ・Solenoid valve (electromagnetic valve) ・Suitable for real-time measurement and feedback control of PWM current of actuators, etc. ・Shunt resistance 40mΩ or less for charging current evaluation ・CAN 2ms ~ Update Output/Setting Significantly reduces the number of wiring compared to BCD ・16bit analog 2ms ~ update output Arbitrary scaling and zero adjustment possible ・Power supply, measurement, and settings via USB. Setting values ​​can be saved and verified, allowing safe management of equipment settings. - Lightweight at 60g, can be customized on a DIN rail (mounting hardware sold separately). We can also offer waterproof housing versions and multi-channel measuring instruments that combine speed measurement. ・LINKSHIP compatible Measurement management software ahead of the times (free of charge) ■Front USB Type-C connector Power supply, logging, and settings are possible with USB. Equipped with the industry's first 24 x 48 USB Type-C connector. Settings and power supply can be done from the front without opening the panel. ■CAN output 2ms update Since it uses 3-wire wiring, the number of wiring can be significantly reduced compared to BCD output. Powerful error detection system is resistant to noise and improves safety. ■16bit analog output 2ms update Resolution of over 50,000. Full scale and zero scale settings are possible, and arbitrary scaling is possible. Analog output zero adjustment is also possible. ■±5A/±2A/±200mA/±20mA DC Four models are available in the measurement range (select the model). Other ranges are also available upon request. ■Input resolution 16bit Over 50,000 input resolution on each range. ■Shunt resistance 40mΩ or less Loss due to shunt resistance can be significantly reduced. ■DC power supply voltage +7V to +60V Wide power supply voltage range compatible with DC12V/24V/448V. ■Isolation Electrically isolated between power supply/current input/other input/output. ■Quick pocket Contains a specification summary with notes. Usage instructions and setting values ​​can be written and viewed immediately on site. ■Mounting hook Fix the main body with the left and right mounting hooks. ■Detachable plug connector Our company is the first in the industry to use 24×48. All you have to do is connect the wires to the plug connector in advance and insert them by hand. ■DIN rail mountable Compatible with DIN rail mounting, convenient for use as a converter inside a control panel.

  • Product

    DC ammeter PSA-2401

Share this product


220+ people viewing

Last viewed: 16 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

4 Models of DC ammeter PSA-2401

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Decimal point position Display (numeric) Display moving average number of times Display range Display update time Hold function Hold input Indicator Input connector Input resistance Input signal Isolation Low cut function Low pass filter Mass Maximum allowable input Measurement accuracy Measurement resolution Measuring range Moving average number Number of input points Operation method Output update time Power consumption Power supply voltage Sampling rate Setting value memory USB communication function USB communication specifications Withstand voltage
DC ammeter PSA-2401-Part Number-PSA-2401 ±20mA type

PSA-2401 ±20mA type

Available upon quote Set in program mode
0:□□□□□ (no decimal point) 1:□□□□.□~4:□.□□□□
7seg 5 digits (character height 9mm) Red, can be turned off, brightness adjustment in 10 levels 1~9 times: configurable -19,999~99,999
Over display: OL Zero display: Leading zero suppression
0.3 seconds (can be set in the range of 0.1~9.9 seconds) Current value/Maximum value/Minimum value/Maximum fluctuation range value 1 point: ON when shorted to GND, OFF when opened 1 point Select from power/hold Spring lock plug connector Approximately 1Ω DC current signal Power supply/current input/other input/output 0 judgment when the current value is less than the set value Cutoff frequency 1kHz (custom order available) Approximately 60g -3~+3A ±0.1%FS+1digit 0.001mA -20.000~+20.000mA 1~99 1 point ⊿Σ integral method 2ms~9,999ms Set in 1ms increments 3W or less DC+7V~+60V (with reverse connection protection) Power supply from USB host: 5V Select from 8/16/32/64/128/250/860sps (times/second)
Oversampling frequency fixed at 250kHz
Non-volatile memory (EEPROM) Writing/reading of set values/continuous output of measured values USB2.0 (serial port communication 230.4kbps via USB virtual COM) Power supply/current input/other input/output: 500V DC for 1 minute between each terminal
DC ammeter PSA-2401-Part Number-PSA-2401 ±200mA type

PSA-2401 ±200mA type

Available upon quote Set in program mode
0:□□□□□ (no decimal point) 1:□□□□.□~4:□.□□□□
7seg 5 digits (character height 9mm) Red, can be turned off, brightness adjustment in 10 levels 1~9 times: configurable -19,999~99,999
Over display: OL Zero display: Leading zero suppression
0.3 seconds (can be set in the range of 0.1~9.9 seconds) Current value/Maximum value/Minimum value/Maximum fluctuation range value 1 point: ON when shorted to GND, OFF when opened 1 point Select from power/hold Spring lock plug connector Approximately 100mΩ DC current signal Power supply/current input/other input/output 0 judgment when the current value is less than the set value Cutoff frequency 1kHz (custom order available) Approximately 60g -3~+3A ±0.1%FS+1digit 0.01mA -200.00~+200.00mA 1~99 1 point ⊿Σ integral method 2ms~9,999ms Set in 1ms increments 3W or less DC+7V~+60V (with reverse connection protection) Power supply from USB host: 5V Select from 8/16/32/64/128/250/860sps (times/second)
Oversampling frequency fixed at 250kHz
Non-volatile memory (EEPROM) Writing/reading of set values/continuous output of measured values USB2.0 (serial port communication 230.4kbps via USB virtual COM) Power supply/current input/other input/output: 500V DC for 1 minute between each terminal
DC ammeter PSA-2401-Part Number-PSA-2401 ±2A type

PSA-2401 ±2A type

Available upon quote Set in program mode
0:□□□□□ (no decimal point) 1:□□□□.□~4:□.□□□□
7seg 5 digits (character height 9mm) Red, can be turned off, brightness adjustment in 10 levels 1~9 times: configurable -19,999~99,999
Over display: OL Zero display: Leading zero suppression
0.3 seconds (can be set in the range of 0.1~9.9 seconds) Current value/Maximum value/Minimum value/Maximum fluctuation range value 1 point: ON when shorted to GND, OFF when opened 1 point Select from power/hold Spring lock plug connector Approximately 40mΩ DC current signal Power supply/current input/other input/output 0 judgment when the current value is less than the set value Cutoff frequency 1kHz (custom order available) Approximately 60g -3~+3A ±0.1%FS+1digit 0.1mA -2000.0~+2000.0mA 1~99 1 point ⊿Σ integral method 2ms~9,999ms Set in 1ms increments 3W or less DC+7V~+60V (with reverse connection protection) Power supply from USB host: 5V Select from 8/16/32/64/128/250/860sps (times/second)
Oversampling frequency fixed at 250kHz
Non-volatile memory (EEPROM) Writing/reading of set values/continuous output of measured values USB2.0 (serial port communication 230.4kbps via USB virtual COM) Power supply/current input/other input/output: 500V DC for 1 minute between each terminal
DC ammeter PSA-2401-Part Number-PSA-2401 ±5A type

PSA-2401 ±5A type

Available upon quote Set in program mode
0:□□□□□ (no decimal point) 1:□□□□.□~4:□.□□□□
7seg 5 digits (character height 9mm) Red, can be turned off, brightness adjustment in 10 levels 1~9 times: configurable -19,999~99,999
Over display: OL Zero display: Leading zero suppression
0.3 seconds (can be set in the range of 0.1~9.9 seconds) Current value/Maximum value/Minimum value/Maximum fluctuation range value 1 point: ON when shorted to GND, OFF when opened 1 point Select from power/hold Spring lock plug connector Approximately 40mΩ DC current signal Power supply/current input/other input/output 0 judgment when the current value is less than the set value Cutoff frequency 1kHz (custom order available) Approximately 60g -6~+6A ±0.1%FS+1digit 0.25mA -5,000.0~+5,000.0mA 1~99 1 point ⊿Σ integral method 2ms~9,999ms Set in 1ms increments 3W or less DC+7V~+60V (with reverse connection protection) Power supply from USB host: 5V Select from 8/16/32/64/128/250/860sps (times/second)
Oversampling frequency fixed at 250kHz
Non-volatile memory (EEPROM) Writing/reading of set values/continuous output of measured values USB2.0 (serial port communication 230.4kbps via USB virtual COM) Power supply/current input/other input/output: 500V DC for 1 minute between each terminal

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Coco Research Co., Ltd.


View more products of Coco Research Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree