All Categories

History

DC ammeter PSA-2401-PSA-2401 ±20mA type
DC ammeter PSA-2401-Coco Research Co., Ltd.

DC ammeter PSA-2401
Coco Research Co., Ltd.

Coco Research Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

59.6hours


About This Product

■Summary

Accurately responds to rapid fluctuations with breakthrough speed. Achieved a 40mΩ shunt for PWM current/charging current measurement.

■Features

・Solenoid valve (electromagnetic valve) ・Suitable for real-time measurement and feedback control of PWM current of actuators, etc. ・Shunt resistance 40mΩ or less for charging current evaluation ・CAN 2ms ~ Update Output/Setting Significantly reduces the number of wiring compared to BCD ・16bit analog 2ms ~ update output Arbitrary scaling and zero adjustment possible ・Power supply, measurement, and settings via USB. Setting values ​​can be saved and verified, allowing safe management of equipment settings. - Lightweight at 60g, can be customized on a DIN rail (mounting hardware sold separately). We can also offer waterproof housing versions and multi-channel measuring instruments that combine speed measurement. ・LINKSHIP compatible Measurement management software ahead of the times (free of charge)

■Front USB Type-C connector

Power supply, logging, and settings are possible with USB. Equipped with the industry's first 24 x 48 USB Type-C connector. Settings and power supply can be done from the front without opening the panel.

■CAN output 2ms update

Since it uses 3-wire wiring, the number of wiring can be significantly reduced compared to BCD output. Powerful error detection system is resistant to noise and improves safety.

■16bit analog output 2ms update

Resolution of over 50,000. Full scale and zero scale settings are possible, and arbitrary scaling is possible. Analog output zero adjustment is also possible.

■±5A/±2A/±200mA/±20mA DC

Four models are available in the measurement range (select the model). Other ranges are also available upon request.

■Input resolution 16bit

Over 50,000 input resolution on each range.

■Shunt resistance 40mΩ or less

Loss due to shunt resistance can be significantly reduced.

■DC power supply voltage +7V to +60V

Wide power supply voltage range compatible with DC12V/24V/448V.

■Isolation

Electrically isolated between power supply/current input/other input/output.

■Quick pocket

Contains a specification summary with notes. Usage instructions and setting values ​​can be written and viewed immediately on site.

■Mounting hook

Fix the main body with the left and right mounting hooks.

■Detachable plug connector

Our company is the first in the industry to use 24×48. All you have to do is connect the wires to the plug connector in advance and insert them by hand.

■DIN rail mountable

Compatible with DIN rail mounting, convenient for use as a converter inside a control panel.

  • Product

    DC ammeter PSA-2401

Share this product


260+ people viewing

Last viewed: 19 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

4 Models of DC ammeter PSA-2401

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply voltage Mass Setting value memory Measurement accuracy Measuring range Measurement resolution Display range Display moving average number of times Display update time Display (numeric) Withstand voltage Moving average number Power consumption Maximum allowable input Decimal point position Operation method Output update time Number of input points Input resistance Input signal Input connector Low pass filter Low cut function Hold function Hold input Sampling rate Indicator Isolation USB communication function USB communication specifications
DC ammeter PSA-2401-Part Number-PSA-2401 ±20mA type

PSA-2401 ±20mA type

Available upon quote

DC+7V~+60V (with reverse connection protection) Power supply from USB host: 5V

Approximately 60g

Non-volatile memory (EEPROM)

±0.1%FS+1digit

-20.000~+20.000mA

0.001mA

-19,999~99,999
Over display: OL Zero display: Leading zero suppression

1~9 times: configurable

0.3 seconds (can be set in the range of 0.1~9.9 seconds)

7seg 5 digits (character height 9mm) Red, can be turned off, brightness adjustment in 10 levels

Power supply/current input/other input/output: 500V DC for 1 minute between each terminal

1~99

3W or less

-3~+3A

Set in program mode
0:□□□□□ (no decimal point) 1:□□□□.□~4:□.□□□□

⊿Σ integral method

2ms~9,999ms Set in 1ms increments

1 point

Approximately 1Ω

DC current signal

Spring lock plug connector

Cutoff frequency 1kHz (custom order available)

0 judgment when the current value is less than the set value

Current value/Maximum value/Minimum value/Maximum fluctuation range value

1 point: ON when shorted to GND, OFF when opened

Select from 8/16/32/64/128/250/860sps (times/second)
Oversampling frequency fixed at 250kHz

1 point Select from power/hold

Power supply/current input/other input/output

Writing/reading of set values/continuous output of measured values

USB2.0 (serial port communication 230.4kbps via USB virtual COM)

DC ammeter PSA-2401-Part Number-PSA-2401 ±200mA type

PSA-2401 ±200mA type

Available upon quote

DC+7V~+60V (with reverse connection protection) Power supply from USB host: 5V

Approximately 60g

Non-volatile memory (EEPROM)

±0.1%FS+1digit

-200.00~+200.00mA

0.01mA

-19,999~99,999
Over display: OL Zero display: Leading zero suppression

1~9 times: configurable

0.3 seconds (can be set in the range of 0.1~9.9 seconds)

7seg 5 digits (character height 9mm) Red, can be turned off, brightness adjustment in 10 levels

Power supply/current input/other input/output: 500V DC for 1 minute between each terminal

1~99

3W or less

-3~+3A

Set in program mode
0:□□□□□ (no decimal point) 1:□□□□.□~4:□.□□□□

⊿Σ integral method

2ms~9,999ms Set in 1ms increments

1 point

Approximately 100mΩ

DC current signal

Spring lock plug connector

Cutoff frequency 1kHz (custom order available)

0 judgment when the current value is less than the set value

Current value/Maximum value/Minimum value/Maximum fluctuation range value

1 point: ON when shorted to GND, OFF when opened

Select from 8/16/32/64/128/250/860sps (times/second)
Oversampling frequency fixed at 250kHz

1 point Select from power/hold

Power supply/current input/other input/output

Writing/reading of set values/continuous output of measured values

USB2.0 (serial port communication 230.4kbps via USB virtual COM)

DC ammeter PSA-2401-Part Number-PSA-2401 ±2A type

PSA-2401 ±2A type

Available upon quote

DC+7V~+60V (with reverse connection protection) Power supply from USB host: 5V

Approximately 60g

Non-volatile memory (EEPROM)

±0.1%FS+1digit

-2000.0~+2000.0mA

0.1mA

-19,999~99,999
Over display: OL Zero display: Leading zero suppression

1~9 times: configurable

0.3 seconds (can be set in the range of 0.1~9.9 seconds)

7seg 5 digits (character height 9mm) Red, can be turned off, brightness adjustment in 10 levels

Power supply/current input/other input/output: 500V DC for 1 minute between each terminal

1~99

3W or less

-3~+3A

Set in program mode
0:□□□□□ (no decimal point) 1:□□□□.□~4:□.□□□□

⊿Σ integral method

2ms~9,999ms Set in 1ms increments

1 point

Approximately 40mΩ

DC current signal

Spring lock plug connector

Cutoff frequency 1kHz (custom order available)

0 judgment when the current value is less than the set value

Current value/Maximum value/Minimum value/Maximum fluctuation range value

1 point: ON when shorted to GND, OFF when opened

Select from 8/16/32/64/128/250/860sps (times/second)
Oversampling frequency fixed at 250kHz

1 point Select from power/hold

Power supply/current input/other input/output

Writing/reading of set values/continuous output of measured values

USB2.0 (serial port communication 230.4kbps via USB virtual COM)

DC ammeter PSA-2401-Part Number-PSA-2401 ±5A type

PSA-2401 ±5A type

Available upon quote

DC+7V~+60V (with reverse connection protection) Power supply from USB host: 5V

Approximately 60g

Non-volatile memory (EEPROM)

±0.1%FS+1digit

-5,000.0~+5,000.0mA

0.25mA

-19,999~99,999
Over display: OL Zero display: Leading zero suppression

1~9 times: configurable

0.3 seconds (can be set in the range of 0.1~9.9 seconds)

7seg 5 digits (character height 9mm) Red, can be turned off, brightness adjustment in 10 levels

Power supply/current input/other input/output: 500V DC for 1 minute between each terminal

1~99

3W or less

-6~+6A

Set in program mode
0:□□□□□ (no decimal point) 1:□□□□.□~4:□.□□□□

⊿Σ integral method

2ms~9,999ms Set in 1ms increments

1 point

Approximately 40mΩ

DC current signal

Spring lock plug connector

Cutoff frequency 1kHz (custom order available)

0 judgment when the current value is less than the set value

Current value/Maximum value/Minimum value/Maximum fluctuation range value

1 point: ON when shorted to GND, OFF when opened

Select from 8/16/32/64/128/250/860sps (times/second)
Oversampling frequency fixed at 250kHz

1 point Select from power/hold

Power supply/current input/other input/output

Writing/reading of set values/continuous output of measured values

USB2.0 (serial port communication 230.4kbps via USB virtual COM)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Galvanometers Products

Other products of Coco Research Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Coco Research Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

59.6hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree