Product
Universal revolution/speed meter TDP-3941Handling Company
Coco Research Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Arithmetic unit Dynamic prediction TM | Arithmetic unit moving average | Calculation clock | Calculation part Frequency division ratio (pulse average) | Calculation section Setting value memory | Computation rate | Computation section Measurement mode | Display | Display Decimal point position | Display accuracy | Display color | Display digits | Display moving average | Display range | Display range switching | Display update time | Input frequency range | Input indicator | Input level | Input pulse width | Input resistance | Input section Trigger direction | Input section noise filter | Input signal | Input withstand voltage | Number of input points | Opa display | Polarity display | Trigger display | Zero display |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TDP-3941-RAF |
Available upon quote |
8 stages (including continuous prediction and cycle retention) *Remove the front panel to configure internal settings. |
Displayed 1 to 10 times (equivalent to the number of display updates) Analog output 1~32 pulses (equivalent to the number of input pulses) |
80MHz |
1-255 (software division) *Remove the front panel to configure internal settings. |
Non-Eruptive Memory (EEPROM) |
Input frequency rate: 0.00001~999,999 (Hz) Display rate: 0.00001~999,999 |
Frequency meter mode only | 7 segment LED character height 14.2mm | Rorororororo.~rororororo | 20ppm soil 1 tegit (@23℃) | Red | 6 digits | 1~10 times | -99,999~999,999 |
Auto range or fixed range (decimal point position) setting *Remove the front panel to configure internal settings. |
0.1~2.0s Can be set in 0.1s (seconds) increments | 0.1Hz~30kHz | SIG: Decrease at pulse input (continuously lights up with high-speed pulse) |
Logic: H level 3.5V or more, L level 1V or less Zero cross: AC signal from 100mV to 50V (① Single phase signal only @1kHz input) Line driver: H level 3.0V or more, L level 1V or less |
10μs or more (both L level and H level) Phase difference and overlap of A/B phase signals are each 5μs or more |
General-purpose input: 100kΩ when not pulled up, 4.3kΩ when pulled up Line driver input: approx. 1kΩ |
Rising or falling *Remove the front panel and configure the internal settings. |
Low-pass filter circuit 2 steps (general-purpose input only) OFF:2.4μs (30kHz-3dB, -6dB/oct.) ON:100μs (1kHz-3dB, -6dB/oct.) |
① Single phase signal ②UP/DOWN signal (separate pulse) ③A/B phase signal (9 is phase difference) |
①General-purpose input: ±50V when not pulled up, ±40V when pulled up ②Line driver input: Sat 15V |
1 point | According to OL display | - is lit + is not lit |
Lights up when triggered by input signal (For A/B phase signals, lights up at the rising and falling edges of A and B signals) |
Leading zero suppress | |
TDP-3941-GRAF |
Available upon quote |
8 stages (including continuous prediction and cycle retention) *Remove the front panel to configure internal settings. |
Displayed 1 to 10 times (equivalent to the number of display updates) Analog output 1~32 pulses (equivalent to the number of input pulses) |
80MHz |
1-255 (software division) *Remove the front panel to configure internal settings. |
Non-Eruptive Memory (EEPROM) |
Input frequency rate: 0.00001~999,999 (Hz) Display rate: 0.00001~999,999 |
Frequency meter mode only | 7 segment LED character height 14.2mm | Rorororororo.~rororororo | 20ppm soil 1 tegit (@23℃) | Green | 6 digits | 1~10 times | -99,999~999,999 |
Auto range or fixed range (decimal point position) setting *Remove the front panel to configure internal settings. |
0.1~2.0s Can be set in 0.1s (seconds) increments | 0.1Hz~30kHz | SIG: Decrease at pulse input (continuously lights up with high-speed pulse) |
Logic: H level 3.5V or more, L level 1V or less Zero cross: AC signal from 100mV to 50V (① Single phase signal only @1kHz input) Line driver: H level 3.0V or more, L level 1V or less |
10μs or more (both L level and H level) Phase difference and overlap of A/B phase signals are each 5μs or more |
General-purpose input: 100kΩ when not pulled up, 4.3kΩ when pulled up Line driver input: approx. 1kΩ |
Rising or falling *Remove the front panel and configure the internal settings. |
Low-pass filter circuit 2 steps (general-purpose input only) OFF:2.4μs (30kHz-3dB, -6dB/oct.) ON:100μs (1kHz-3dB, -6dB/oct.) |
① Single phase signal ②UP/DOWN signal (separate pulse) ③A/B phase signal (9 is phase difference) |
①General-purpose input: ±50V when not pulled up, ±40V when pulled up ②Line driver input: Sat 15V |
1 point | According to OL display | - is lit + is not lit |
Lights up when triggered by input signal (For A/B phase signals, lights up at the rising and falling edges of A and B signals) |
Leading zero suppress |