Switching power supply AE series AE-800Handling Company
Denryo Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Harmonic current | Current error range | Voltage error range | Overvoltage protection | Overload protection | Overtemperature | Startup time | Load fluctuation | Auxiliary power | Inrush current (typical value) | Leakage current | Rated current | Rated output power | Safety standards | Efficiency (maximum) | Power factor (typical value) | Output current adjustment | Output voltage adjustment | Output voltage variable range | Output voltage | Input current (maximum) | Input voltage range | Input fluctuation | Input frequency | Retention time (typical value) | Parallel operation (current sharing) | Remote ON/OFF control | Ripple noise (maximum value) | POWER OK signal | EMI |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AE-800-12 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
±3.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
800ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
30A/115Vac, 60A/230Vac |
<3.5mA/240Vac |
66.7A |
800W |
EN62368-1, UL62368-1 |
89% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
12V |
9.3A/115Vac, 3.5A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
8ms/230Vac (at rated load) |
Possible |
External switch |
120mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |
|
AE-800-15 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
±3.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
800ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
30A/115Vac, 60A/230Vac |
<3.5mA/240Vac |
53.4A |
800W |
EN62368-1, UL62368-1 |
90% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
15V |
9.3A/115Vac, 3.5A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
8ms/230Vac (at rated load) |
Possible |
External switch |
150mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |
|
AE-800-24 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
±3.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
800ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
30A/115Vac, 60A/230Vac |
<3.5mA/240Vac |
33.5A |
800W |
EN62368-1, UL62368-1 |
92% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
24V |
9.3A/115Vac, 3.5A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
8ms/230Vac (at rated load) |
Possible |
External switch |
240mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |
|
AE-800-30 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
±3.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
800ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
30A/115Vac, 60A/230Vac |
<3.5mA/240Vac |
26.7A |
800W |
EN62368-1, UL62368-1 |
92% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
30V |
9.3A/115Vac, 3.5A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
8ms/230Vac (at rated load) |
Possible |
External switch |
300mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |
|
AE-800-36 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
±3.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
800ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
30A/115Vac, 60A/230Vac |
<3.5mA/240Vac |
22.3A |
800W |
EN62368-1, UL62368-1 |
92% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
36V |
9.3A/115Vac, 3.5A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
8ms/230Vac (at rated load) |
Possible |
External switch |
360mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |
|
AE-800-48 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
±3.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
800ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
30A/115Vac, 60A/230Vac |
<3.5mA/240Vac |
16.7A |
800W |
EN62368-1, UL62368-1 |
92% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
48V |
9.3A/115Vac, 3.5A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
8ms/230Vac (at rated load) |
Possible |
External switch |
480mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |
|
AE-800-60 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
±3.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
800ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
30A/115Vac, 60A/230Vac |
<3.5mA/240Vac |
13.4A |
800W |
EN62368-1, UL62368-1 |
93% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
60V |
9.3A/115Vac, 3.5A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
8ms/230Vac (at rated load) |
Possible |
External switch |
600mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |