Product Image | Part Number | Price (excluding tax) | Auxiliary power | Current error range | EMI | Efficiency (maximum) | Harmonic current | Input current (maximum) | Input fluctuation | Input frequency | Input voltage range | Inrush current (typical value) | Leakage current | Load fluctuation | Output current adjustment | Output voltage | Output voltage adjustment | Output voltage variable range | Overload protection | Overtemperature | Overvoltage protection | POWER OK signal | Parallel operation (current sharing) | Power factor (typical value) | Rated current | Rated output power | Remote ON/OFF control | Retention time (typical value) | Ripple noise (maximum value) | Safety standards | Startup time | Voltage error range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AE-1500-12 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | ±2.0% | EN55032 | 89% | EN61000-3-2, EN61000-3-3 | 18A/115Vac, 9A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 30A/115Vac, 45A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 12V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.99/115Vac (at rated load) | 125A | 1,500W | External switch | 14ms/230Vac (at rated load) | 150mVp-p | EN62368-1, UL62368-1 | 800ms, 100ms (at rated load) | ±3.0% | |
AE-1500-15 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | ±2.0% | EN55032 | 90% | EN61000-3-2, EN61000-3-3 | 18A/115Vac, 9A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 30A/115Vac, 45A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 15V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.99/115Vac (at rated load) | 100A | 1,500W | External switch | 14ms/230Vac (at rated load) | 150mVp-p | EN62368-1, UL62368-1 | 800ms, 100ms (at rated load) | ±3.0% | |
AE-1500-24 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | ±2.0% | EN55032 | 92% | EN61000-3-2, EN61000-3-3 | 18A/115Vac, 9A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 30A/115Vac, 45A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 24V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.99/115Vac (at rated load) | 62.5A | 1,500W | External switch | 14ms/230Vac (at rated load) | 240mVp-p | EN62368-1, UL62368-1 | 800ms, 100ms (at rated load) | ±3.0% | |
AE-1500-30 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | ±2.0% | EN55032 | 92% | EN61000-3-2, EN61000-3-3 | 18A/115Vac, 9A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 30A/115Vac, 45A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 30V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.99/115Vac (at rated load) | 50A | 1,500W | External switch | 14ms/230Vac (at rated load) | 300mVp-p | EN62368-1, UL62368-1 | 800ms, 100ms (at rated load) | ±3.0% | |
AE-1500-36 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | ±2.0% | EN55032 | 92% | EN61000-3-2, EN61000-3-3 | 18A/115Vac, 9A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 30A/115Vac, 45A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 36V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.99/115Vac (at rated load) | 41.7A | 1,500W | External switch | 14ms/230Vac (at rated load) | 360mVp-p | EN62368-1, UL62368-1 | 800ms, 100ms (at rated load) | ±3.0% | |
AE-1500-48 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | ±2.0% | EN55032 | 92% | EN61000-3-2, EN61000-3-3 | 18A/115Vac, 9A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 30A/115Vac, 45A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 48V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.99/115Vac (at rated load) | 31.3A | 1,500W | External switch | 14ms/230Vac (at rated load) | 480mVp-p | EN62368-1, UL62368-1 | 800ms, 100ms (at rated load) | ±3.0% | |
AE-1500-60 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | ±2.0% | EN55032 | 93% | EN61000-3-2, EN61000-3-3 | 18A/115Vac, 9A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 30A/115Vac, 45A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 60V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.99/115Vac (at rated load) | 25A | 1,500W | External switch | 14ms/230Vac (at rated load) | 600mVp-p | EN62368-1, UL62368-1 | 800ms, 100ms (at rated load) | ±3.0% |