Product
Switching power supply AE series AE-3000Handling Company
Denryo Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Auxiliary power | EMI | EMS immunity | Efficiency (maximum) | Harmonic current | Input current (maximum) | Input fluctuation | Input frequency | Input voltage range | Inrush current (typical value) | Leakage current | Load fluctuation | Output current adjustment | Output voltage | Output voltage adjustment | Output voltage variable range | Overload protection | Overtemperature | Overvoltage protection | POWER OK signal | Parallel operation (current sharing) | Power factor (typical value) | Rated current | Rated output power | Remote ON/OFF control | Retention time (typical value) | Ripple noise (maximum value) | Safety standards | Startup time | Voltage error range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AE-3000-12 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | EN55032 | EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 | 89% | EN61000-3-2, EN61000-3-3 | 36A/115Vac, 18A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 60A/115Vac, 90A/230Vac | <2.5mA/240Vac | ±1.0% | 0~105% | 12V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 250A | 3,000W | External switch | 14ms/230Vac (at rated load) | 150mVp-p | EN62368-1, UL62368-1 | 2,000ms, 100ms (at rated load) | ±2.0% | |
AE-3000-15 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | EN55032 | EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 | 90% | EN61000-3-2, EN61000-3-3 | 36A/115Vac, 18A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 60A/115Vac, 90A/230Vac | <2.5mA/240Vac | ±1.0% | 0~105% | 15V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 200A | 3,000W | External switch | 14ms/230Vac (at rated load) | 150mVp-p | EN62368-1, UL62368-1 | 2,000ms, 100ms (at rated load) | ±2.0% | |
AE-3000-24 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | EN55032 | EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 | 91% | EN61000-3-2, EN61000-3-3 | 36A/115Vac, 18A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 60A/115Vac, 90A/230Vac | <2.5mA/240Vac | ±1.0% | 0~105% | 24V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 125A | 3,000W | External switch | 14ms/230Vac (at rated load) | 240mVp-p | EN62368-1, UL62368-1 | 2,000ms, 100ms (at rated load) | ±2.0% | |
AE-3000-30 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | EN55032 | EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 | 91% | EN61000-3-2, EN61000-3-3 | 36A/115Vac, 18A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 60A/115Vac, 90A/230Vac | <2.5mA/240Vac | ±1.0% | 0~105% | 30V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 100A | 3,000W | External switch | 14ms/230Vac (at rated load) | 300mVp-p | EN62368-1, UL62368-1 | 2,000ms, 100ms (at rated load) | ±2.0% | |
AE-3000-36 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | EN55032 | EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 | 92% | EN61000-3-2, EN61000-3-3 | 36A/115Vac, 18A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 60A/115Vac, 90A/230Vac | <2.5mA/240Vac | ±1.0% | 0~105% | 36V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 83.5A | 3,000W | External switch | 14ms/230Vac (at rated load) | 360mVp-p | EN62368-1, UL62368-1 | 2,000ms, 100ms (at rated load) | ±2.0% | |
AE-3000-48 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | EN55032 | EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 | 92% | EN61000-3-2, EN61000-3-3 | 36A/115Vac, 18A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 60A/115Vac, 90A/230Vac | <2.5mA/240Vac | ±1.0% | 0~105% | 48V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 62.5A | 3,000W | External switch | 14ms/230Vac (at rated load) | 480mVp-p | EN62368-1, UL62368-1 | 2,000ms, 100ms (at rated load) | ±2.0% | |
AE-3000-60 |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | EN55032 | EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 | 93% | EN61000-3-2, EN61000-3-3 | 36A/115Vac, 18A/230Vac | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 60A/115Vac, 90A/230Vac | <2.5mA/240Vac | ±1.0% | 0~105% | 60V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | 120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 50A | 3,000W | External switch | 14ms/230Vac (at rated load) | 600mVp-p | EN62368-1, UL62368-1 | 2,000ms, 100ms (at rated load) | ±2.0% |