Switching power supply AE series AE-3000Handling Company
Denryo Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Harmonic current | Voltage error range | Overvoltage protection | Overload protection | Overtemperature | Startup time | Load fluctuation | Auxiliary power | Inrush current (typical value) | Leakage current | Rated current | Rated output power | Safety standards | Efficiency (maximum) | Power factor (typical value) | Output current adjustment | Output voltage adjustment | Output voltage variable range | Output voltage | Input current (maximum) | Input voltage range | Input fluctuation | Input frequency | Retention time (typical value) | Parallel operation (current sharing) | Remote ON/OFF control | Ripple noise (maximum value) | POWER OK signal | EMS immunity | EMI |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
AE-3000-12 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
2,000ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
60A/115Vac, 90A/230Vac |
<2.5mA/240Vac |
250A |
3,000W |
EN62368-1, UL62368-1 |
89% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
12V |
36A/115Vac, 18A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
150mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 |
EN55032 |
AE-3000-15 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
2,000ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
60A/115Vac, 90A/230Vac |
<2.5mA/240Vac |
200A |
3,000W |
EN62368-1, UL62368-1 |
90% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
15V |
36A/115Vac, 18A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
150mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 |
EN55032 |
|
AE-3000-24 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
2,000ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
60A/115Vac, 90A/230Vac |
<2.5mA/240Vac |
125A |
3,000W |
EN62368-1, UL62368-1 |
91% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
24V |
36A/115Vac, 18A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
240mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 |
EN55032 |
|
AE-3000-30 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
2,000ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
60A/115Vac, 90A/230Vac |
<2.5mA/240Vac |
100A |
3,000W |
EN62368-1, UL62368-1 |
91% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
30V |
36A/115Vac, 18A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
300mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 |
EN55032 |
|
AE-3000-36 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
2,000ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
60A/115Vac, 90A/230Vac |
<2.5mA/240Vac |
83.5A |
3,000W |
EN62368-1, UL62368-1 |
92% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
36V |
36A/115Vac, 18A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
360mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 |
EN55032 |
|
AE-3000-48 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
2,000ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
60A/115Vac, 90A/230Vac |
<2.5mA/240Vac |
62.5A |
3,000W |
EN62368-1, UL62368-1 |
92% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
48V |
36A/115Vac, 18A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
480mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 |
EN55032 |
|
AE-3000-60 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±2.0% |
120±7% of output voltage, protection type: latch style (recovery by re-applying AC input or by resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
2,000ms, 100ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
60A/115Vac, 90A/230Vac |
<2.5mA/240Vac |
50A |
3,000W |
EN62368-1, UL62368-1 |
93% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
60V |
36A/115Vac, 18A/230Vac |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
600mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55024, IEC61000-4-2, 3, 4, 5, 6, 8, 11 |
EN55032 |