Switching power supply AEK series AEK-3000HVHandling Company
Denryo Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Harmonic current | Current error range | Voltage error range | Overvoltage protection | Overload protection | Overtemperature | Startup time | Load fluctuation | Auxiliary power | Inrush current (typical value) | Leakage current | Rated current | Rated output power | Safety standards | Efficiency (maximum) | Power factor (typical value) | Output current adjustment | Output voltage adjustment | Output voltage variable range | Output voltage | Input current (maximum) | Input voltage range | Input fluctuation | Input frequency | Retention time (typical value) | Parallel operation (current sharing) | Remote ON/OFF control | Ripple noise (maximum value) | POWER OK signal | EMI |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AEK-3000-150 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±3.0% |
±2.0% |
Variable overvoltage protection error ±7%, protection type: latch style (recovery by turning on AC input again or resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
1,100ms, 350ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
33A/115Vac, 65A/230Vac |
<3.5mA/240Vac |
20A |
3,000W |
EN62368-1, UL62368-1 |
93% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
150V |
19.7A/115Vac (2,000W), 14.5A/230Vac (3,000W) |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
1,500mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |
|
AEK-3000-200 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±3.0% |
±2.0% |
Variable overvoltage protection error ±7%, protection type: latch style (recovery by turning on AC input again or resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
1,100ms, 350ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
33A/115Vac, 65A/230Vac |
<3.5mA/240Vac |
15A |
3,000W |
EN62368-1, UL62368-2 |
93% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
200V |
19.7A/115Vac (2,000W), 14.5A/230Vac (3,000W) |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
2,000mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |
|
AEK-3000-250 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±3.0% |
±2.0% |
Variable overvoltage protection error ±7%, protection type: latch style (recovery by turning on AC input again or resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
1,100ms, 350ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
33A/115Vac, 65A/230Vac |
<3.5mA/240Vac |
12A |
3,000W |
EN62368-1, UL62368-3 |
93% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
250V |
19.7A/115Vac (2,000W), 14.5A/230Vac (3,000W) |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
2,500mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |
|
AEK-3000-300 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±3.0% |
±2.0% |
Variable overvoltage protection error ±7%, protection type: latch style (recovery by turning on AC input again or resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
1,100ms, 350ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
33A/115Vac, 65A/230Vac |
<3.5mA/240Vac |
10A |
3,000W |
EN62368-1, UL62368-4 |
93% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
300V |
19.7A/115Vac (2,000W), 14.5A/230Vac (3,000W) |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
Ripple noise (maximum value) |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |
|
AEK-3000-400 |
Available upon quote |
EN61000-3-2, EN61000-3-3 |
±3.0% |
±2.0% |
Variable overvoltage protection error ±7%, protection type: latch style (recovery by turning on AC input again or resetting the control) |
105% of rated output, protection type: constant current limit |
85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops |
1,100ms, 350ms (at rated load) |
±1.0% |
+5V/0.5A or +9V/0.3A auxiliary output selectable |
33A/115Vac, 65A/230Vac |
<3.5mA/240Vac |
7.5A |
3,000W |
EN62368-1, UL62368-5 |
93% |
0.95/230Vac, 0.98/115Vac (at rated load) |
0~105% |
0~105% |
±5.0% typical value Adjustment by potentiometer (VR1) |
400V |
19.7A/115Vac (2,000W), 14.5A/230Vac (3,000W) |
90~264Vac, 127~370Vdc |
±1.0% |
47~63Hz |
14ms/230Vac (at rated load) |
Possible |
External switch |
4,000mVp-p |
When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V |
EN55032 |