Product Image | Part Number | Price (excluding tax) | Auxiliary power | Communication interface | Current error range | EMI | Efficiency (maximum) | Input current (maximum) | Input fluctuation | Input frequency | Input voltage range | Inrush current (typical value) | Leakage current | Load fluctuation | Output current adjustment | Output voltage | Output voltage adjustment | Output voltage variable range | Overload protection | Overtemperature | Overvoltage protection | POWER OK signal | Parallel operation (current sharing) | Power factor (typical value) | Rated current | Rated output power | Remote ON/OFF control | Retention time (typical value) | Ripple noise (maximum value) | Safety standards | Startup time | Voltage error range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AEK-3000-150 Oring Diode |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | Built-in RS-485, I²C | ±3.0% | EN55032 | 91% | 19.7A/115Vac (2,000W), 14.5A/230Vac (3,000W) | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 33A/115Vac, 65A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 150V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | Variable overvoltage protection error ±7%, protection type: latch style (recovery by turning on AC input again or resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 20A | 3,000W | External switch | 14ms/230Vac (at rated load) | 1,500mVp-p | EN62368-1, UL62368-1 | 1,100ms, 350ms (at rated load) | ±2.0% | |
AEK-3000-200 Oring Diode |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | Built-in RS-485, I²C | ±3.0% | EN55032 | 91% | 19.7A/115Vac (2,000W), 14.5A/230Vac (3,000W) | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 33A/115Vac, 65A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 200V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | Variable overvoltage protection error ±7%, protection type: latch style (recovery by turning on AC input again or resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 15A | 3,000W | External switch | 14ms/230Vac (at rated load) | 2,000mVp-p | EN62368-1, UL62368-1 | 1,100ms, 350ms (at rated load) | ±2.0% | |
AEK-3000-250 Oring Diode |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | Built-in RS-485, I²C | ±3.0% | EN55032 | 91% | 19.7A/115Vac (2,000W), 14.5A/230Vac (3,000W) | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 33A/115Vac, 65A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 250V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | Variable overvoltage protection error ±7%, protection type: latch style (recovery by turning on AC input again or resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 12A | 3,000W | External switch | 14ms/230Vac (at rated load) | 2,500mVp-p | EN62368-1, UL62368-1 | 1,100ms, 350ms (at rated load) | ±2.0% | |
AEK-3000-300 Oring Diode |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | Built-in RS-485, I²C | ±3.0% | EN55032 | 91% | 19.7A/115Vac (2,000W), 14.5A/230Vac (3,000W) | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 33A/115Vac, 65A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 300V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | Variable overvoltage protection error ±7%, protection type: latch style (recovery by turning on AC input again or resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 10A | 3,000W | External switch | 14ms/230Vac (at rated load) | 3,000mVp-p | EN62368-1, UL62368-1 | 1,100ms, 350ms (at rated load) | ±2.0% | |
AEK-3000-400 Oring Diode |
Available upon quote | +5V/0.5A or +9V/0.3A auxiliary output selectable | Built-in RS-485, I²C | ±3.0% | EN55032 | 91% | 19.7A/115Vac (2,000W), 14.5A/230Vac (3,000W) | ±1.0% | 47~63Hz | 90~264Vac, 127~370Vdc | 33A/115Vac, 65A/230Vac | <3.5mA/240Vac | ±1.0% | 0~105% | 400V | 0~105% | ±5.0% typical value Adjustment by potentiometer (VR1) | 105% of rated output, protection type: constant current limit | 85±5℃ (detected by NTC thermistor), protection type: automatic recovery when temperature drops | Variable overvoltage protection error ±7%, protection type: latch style (recovery by turning on AC input again or resetting the control) | When the power is turned on, the open drain signal drops. Maximum sink current 20mA. Maximum drain voltage 40V | Possible | 0.95/230Vac, 0.98/115Vac (at rated load) | 7.5A | 3,000W | External switch | 14ms/230Vac (at rated load) | 4,000mVp-p | EN62368-1, UL62368-1 | 1,100ms, 350ms (at rated load) | ±2.0% |
Click on the part number for more information about each product