About This Product

The CX series is an advanced battery charger that allows you to set the charging voltage. The DIP switch on the main unit allows you to easily set the charging voltage according to the specifications of lead-acid batteries (gel, AGM). Automatically controls according to battery voltage. Additionally, charging voltage and charging time can be customized, allowing you to charge a variety of battery types, including lead-acid batteries (gel, AGM), lithium-ion, nickel-cadmium, and more. The CX series has 6 models to choose from, depending on battery voltage and charging current. Compatible with a wide range of battery capacities. Features

■Charging voltage can be set

By simply setting the DIP switch, you can easily set the charging voltage and float voltage according to the specifications of lead-acid batteries (gel, AGM). Automatically controls according to battery voltage.

■Compatible with various batteries

Since charging voltage and charging time can be customized*, it is possible to charge various types of batteries such as lithium ion, nickel cadmium, etc. in addition to lead acid batteries.

■Equipped with power mode

Equipped with a power mode that allows you to maintain battery capacity while using a load. You can build an uninterrupted power supply system or emergency power supply without using relays.

■Equipped with sleep mode

Equipped with a sleep mode that reduces the number of rotations of the cooling fan and the charging current depending on the internal temperature. The operating noise of the cooling fan is reduced, allowing the charger to operate silently.

■Equipped with PFC circuit

Equipped with a power factor correction circuit. Suppresses harmonic components, stabilizes output and reduces wasted power. Achieved high efficiency and power savings of up to 90%.

■Can charge multiple battery banks simultaneously

Since it has multiple output terminals, it is possible to charge different battery banks at the same time. For example, you can charge the engine starting battery and the auxiliary battery at the same time.

■Alarm signal output

Built-in no-voltage contact terminal. An error signal can be output externally when a failure occurs. Suitable for integration into the system.

■Temperature correction function

By using the optional remote temperature sensor CX-RTS, charging voltage and float voltage can be corrected according to battery temperature.

  • Product

    Battery charger CX series

Share this product


450+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Battery charger CX series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Weight Compatible battery Vibration resistance Pressure resistance Insulation resistance Temperature correction factor Maximum charging current Recommended battery capacity Dimensions (L×W×H) Rated output number Safety standards Operating humidity range Operating temperature range Efficiency (230Vac) Cooling Input voltage range Input frequency Charging voltage (can be set with DIP switch) Charging method Protection circuit Float charging voltage (configurable via DIP switch) Battery voltage Type EMC standard AC input power cord 1 output terminal maximum output current ESB output voltage/current ESB output terminal
Battery charger CX series-Part Number-CX1280

CX1280

Available upon quote

3.9kg

Lead acid battery, lithium ion, gel, AGM

10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ

AC Input – DC Output: 4,242Vdc AC Input – Chassis Ground: 1,768Vdc DC Output – Chassis Ground: 707Vdc

AC input – DC output: >100MΩ/500Vdc

-10mV/0.5℃

80A

160~800Ah

312×213×77mm

3

EN60335-1, EN60335-2-29

20~90%RH (no condensation)

-20~+40℃ (rated load), +50℃ (80% load)

87% (average value)

Load temperature linked fan

90~264Vac

47~63Hz

14.4V/14.7V

3 stage charging

Short circuit, over temperature, high voltage

13.5V/13.8V

12V

For 12V battery, maximum charging current 80A

EN61204-3; EN55014-1; EN61000-3-2; EN61000-3-3; EN61000-6-3 IEC61000-4-2, 3, 4, 5, 6, 8, 11 and others

For AC100V, length approximately 1.5m

40A

- -
Battery charger CX series-Part Number-CX1250

CX1250

Available upon quote

2.72kg

Lead acid battery, lithium ion, gel, AGM

10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ

AC Input – DC Output: 4,242Vdc AC Input – Chassis Ground: 1,768Vdc DC Output – Chassis Ground: 707Vdc

AC input – DC output: >100MΩ/500Vdc

-10mV/0.5℃

50A

100~500Ah

272×213×77mm

3

EN60335-1, EN60335-2-29

20~90%RH (no condensation)

-20~+40℃ (rated load), +50℃ (80% load)

87% (average value)

Load temperature linked fan

90~264Vac

47~63Hz

14.4V/14.7V

3 stage charging

Short circuit, over temperature, high voltage

13.5V/13.8V

12V

For 12V battery, maximum charging current 50A

EN61204-3; EN55014-1; EN61000-3-2; EN61000-3-3; EN61000-6-3 IEC61000-4-2, 3, 4, 5, 6, 8, 11 and others

For AC100V, length approximately 1.5m

40A

- -
Battery charger CX series-Part Number-CX1235

CX1235

Available upon quote

1.82kg

Lead acid battery, lithium ion, gel, AGM

10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ

AC Input – DC Output: 4,242Vdc AC Input – Chassis Ground: 1,768Vdc DC Output – Chassis Ground: 707Vdc

AC input – DC output: >100MΩ/500Vdc

-10mV/0.5℃

35A

70~350Ah

263×183×72mm

2

EN60335-1, EN60335-2-29

20~90%RH (no condensation)

-20~+40℃ (rated load), +50℃ (80% load)

87% (average value)

Load temperature linked fan

90~264Vac

47~63Hz

14.4V/14.7V

3 stage charging

Short circuit, over temperature, high voltage

13.5V/13.8V

12V

For 12V battery, maximum charging current 35A

EN61204-3; EN55014-1; EN61000-3-2; EN61000-3-3; EN61000-6-3 IEC61000-4-2, 3, 4, 5, 6, 8, 11 and others

For AC100V, length approximately 1.5m

35A

13.8V/2A

Can be

Battery charger CX series-Part Number-CX1215

CX1215

Available upon quote

1.59kg

Lead acid battery, lithium ion, gel, AGM

10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ

AC Input – DC Output: 4,242Vdc AC Input – Chassis Ground: 1,768Vdc DC Output – Chassis Ground: 707Vdc

AC input – DC output: >100MΩ/500Vdc

-10mV/0.5℃

15A

30~150Ah

243×183×72mm

1

EN60335-1, EN60335-2-29

20~90%RH (no condensation)

-20~+40℃ (rated load), +50℃ (80% load)

87% (average value)

Load temperature linked fan

90~264Vac

47~63Hz

14.4V/14.7V

3 stage charging

Short circuit, over temperature, high voltage

13.5V/13.8V

12V

For 12V battery, maximum charging current 15A

EN61204-3; EN55014-1; EN61000-3-2; EN61000-3-3; EN61000-6-3 IEC61000-4-2, 3, 4, 5, 6, 8, 11 and others

For AC100V, length approximately 1.5m

15A

13.8V/2A

Can be

Battery charger CX series-Part Number-CX2440

CX2440

Available upon quote

3.87kg

Lead acid battery, lithium ion, gel, AGM

10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ

AC Input – DC Output: 4,242Vdc AC Input – Chassis Ground: 1,768Vdc DC Output – Chassis Ground: 707Vdc

AC input – DC output: >100MΩ/500Vdc

-20mV/0.5℃

40A

80~400Ah

312×213×77mm

3

EN60335-1, EN60335-2-29

20~90%RH (no condensation)

-20~+40℃ (rated load), +50℃ (80% load)

90% (average value)

Load temperature linked fan

90~264Vac

47~63Hz

28.8V/29.4V

3 stage charging

Short circuit, over temperature, high voltage

27.0V/27.6V

24V

For 24V battery, maximum charging current 40A

EN61204-3; EN55014-1; EN61000-3-2; EN61000-3-3; EN61000-6-3 IEC61000-4-2, 3, 4, 5, 6, 8, 11 and others

For AC100V, length approximately 1.5m

40A

- -
Battery charger CX series-Part Number-CX2415

CX2415

Available upon quote

1.59kg

Lead acid battery, lithium ion, gel, AGM

10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ

AC Input – DC Output: 4,242Vdc AC Input – Chassis Ground: 1,768Vdc DC Output – Chassis Ground: 707Vdc

AC input – DC output: >100MΩ/500Vdc

-20mV/0.5℃

12.5A

25~125Ah

243×183×72mm

2

EN60335-1, EN60335-2-29

20~90%RH (no condensation)

-20~+40℃ (rated load), +50℃ (80% load)

90% (average value)

Load temperature linked fan

90~264Vac

47~63Hz

28.8V/29.4V

3 stage charging

Short circuit, over temperature, high voltage

27.0V/27.6V

24V

For 24V battery, maximum charging current 12.5A

EN61204-3; EN55014-1; EN61000-3-2; EN61000-3-3; EN61000-6-3 IEC61000-4-2, 3, 4, 5, 6, 8, 11 and others

For AC100V, length approximately 1.5m

12.5A

- -

Click on the part number for more information about each product

Other products of Denryo Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Denryo Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree