DC-AC inverter ST series ST600Handling Company
Denryo Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Weight | Uninterrupted switching time | No load current | Maximum efficiency | Maximum output power (3 minutes) | Dimensions (L×W×H) | Rated output power | Rated input voltage | Frequency (switchable) | Operating temperature range | Output voltage | Output waveform | Cooling | Input voltage range | Protection circuit | Storage temperature/humidity | Breaker | Surge power | EMC standard |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
ST600-148 |
Available upon quote |
3.3kg |
Inverter → commercial power: 4~8msec, commercial power → inverter: ~50msec |
0.25A |
90% |
680VA |
312×179×80mm |
600VA |
48Vdc |
50/60Hz±0.05% |
0~40℃ |
100Vac±5% |
Sine wave (distortion rate 3% or less) |
Load linked fan |
42~60Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, overtemperature |
-30~+70℃ |
7A |
800VA |
- |
ST600-212 |
Available upon quote |
3.3kg |
Inverter → commercial power: 4~8msec, commercial power → inverter: ~50msec |
0.87A |
90% |
680VA |
312×179×80mm |
600VA |
12Vdc |
50/60Hz±0.05% |
0~40℃ |
200Vac±3% |
Sine wave (distortion rate 3% or less) |
Load linked fan |
10.5~15Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, overtemperature |
-30~+70℃ |
3A |
800VA |
EN55022; EN55024; EN61204-3 EN61000-3-2, -3-3 IEC61000-4-2, 3, 4, 5, 6, 8, 11 e-mark e13-022192 |
|
ST600-224 |
Available upon quote |
3.3kg |
Inverter → commercial power: 4~8msec, commercial power → inverter: ~50msec |
0.43A |
93% |
680VA |
312×179×80mm |
600VA |
24Vdc |
50/60Hz±0.05% |
0~40℃ |
200Vac±3% |
Sine wave (distortion rate 3% or less) |
Load linked fan |
21~30Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, overtemperature |
-30~+70℃ |
3A |
800VA |
EN55022; EN55024; EN61204-3 EN61000-3-2, -3-3 IEC61000-4-2, 3, 4, 5, 6, 8, 11 e-mark e13-022193 |
|
ST600-248 |
Available upon quote |
3.3kg |
Inverter → commercial power: 4~8msec, commercial power → inverter: ~50msec |
0.22A |
93% |
680VA |
312×179×80mm |
600VA |
48Vdc |
50/60Hz±0.05% |
0~40℃ |
200Vac±3% |
Sine wave (distortion rate 3% or less) |
Load linked fan |
42~60Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, overtemperature |
-30~+70℃ |
3A |
800VA |
E-mark e13 022986 |