Product
DC-AC inverter ST series ST600Handling Company
Denryo Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Breaker | Cooling | Dimensions (L×W×H) | EMC standard | Frequency (switchable) | Input voltage range | Maximum efficiency | Maximum output power (3 minutes) | No load current | Operating temperature range | Output voltage | Output waveform | Protection circuit | Rated input voltage | Rated output power | Storage temperature/humidity | Surge power | Uninterrupted switching time | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ST600-148 |
Available upon quote | 7A | Load linked fan | 312×179×80mm | - | 50/60Hz±0.05% | 42~60Vdc | 90% | 680VA | 0.25A | 0~40℃ | 100Vac±5% | Sine wave (distortion rate 3% or less) | Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, overtemperature | 48Vdc | 600VA | -30~+70℃ | 800VA | Inverter → commercial power: 4~8msec, commercial power → inverter: ~50msec | 3.3kg | |
ST600-212 |
Available upon quote | 3A | Load linked fan | 312×179×80mm | EN55022; EN55024; EN61204-3 EN61000-3-2, -3-3 IEC61000-4-2, 3, 4, 5, 6, 8, 11 e-mark e13-022192 | 50/60Hz±0.05% | 10.5~15Vdc | 90% | 680VA | 0.87A | 0~40℃ | 200Vac±3% | Sine wave (distortion rate 3% or less) | Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, overtemperature | 12Vdc | 600VA | -30~+70℃ | 800VA | Inverter → commercial power: 4~8msec, commercial power → inverter: ~50msec | 3.3kg | |
ST600-224 |
Available upon quote | 3A | Load linked fan | 312×179×80mm | EN55022; EN55024; EN61204-3 EN61000-3-2, -3-3 IEC61000-4-2, 3, 4, 5, 6, 8, 11 e-mark e13-022193 | 50/60Hz±0.05% | 21~30Vdc | 93% | 680VA | 0.43A | 0~40℃ | 200Vac±3% | Sine wave (distortion rate 3% or less) | Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, overtemperature | 24Vdc | 600VA | -30~+70℃ | 800VA | Inverter → commercial power: 4~8msec, commercial power → inverter: ~50msec | 3.3kg | |
ST600-248 |
Available upon quote | 3A | Load linked fan | 312×179×80mm | E-mark e13 022986 | 50/60Hz±0.05% | 42~60Vdc | 93% | 680VA | 0.22A | 0~40℃ | 200Vac±3% | Sine wave (distortion rate 3% or less) | Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, overtemperature | 48Vdc | 600VA | -30~+70℃ | 800VA | Inverter → commercial power: 4~8msec, commercial power → inverter: ~50msec | 3.3kg |
Click on the part number for more information about each product