All Categories
History
Product
DC-AC inverter SK series SK3000Handling Company
Denryo Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Weight | Maximum no-load current | Maximum standby current (power save mode) | Maximum efficiency | Maximum output power (3 minutes) | Dimensions (L×W×H) | Rated output power | Rated input voltage | Frequency (switchable) | Operating temperature range | Output voltage | Output waveform | Cooling | Input voltage range | Protection circuit | Storage temperature | Surge power | EMC standard |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SK3000-212 |
Available upon quote |
9.8kg |
2.8A |
0.55A |
90% |
3,300VA |
454×209×165mm |
3,000VA |
12Vdc |
50/60Hz±0.5% |
0~40℃ |
200Vac±3% |
Sine wave (distortion rate 3% or less) |
Load linked fan |
10.5~15Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, overtemperature |
-30~+70℃ |
6,000VA |
EN55022; EN55024 EN61000-3-2,-3-3 |
|
SK3000-248 |
Available upon quote |
9.8kg |
0.7A |
0.19A |
94% |
3,300VA |
454×209×165mm |
3,000VA |
48Vdc |
50/60Hz±0.5% |
0~40℃ |
200Vac±3% |
Sine wave (distortion rate 3% or less) |
Load linked fan |
42~60Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, overtemperature |
-30~+70℃ |
6,000VA |
E-mark e13 22845 |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.