Product
DC-AC inverter SP series SP-1000Handling Company
Denryo Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Cooling | Dimensions (L×W×H) | E mark | EMC standard | Frequency (switchable) | Input voltage range | Insulation resistance | Maximum efficiency | Maximum output power (1 minute) | No load current | Operating temperature range | Output voltage (switchable) | Output waveform | Pressure resistance | Protection circuit | Rated input voltage | Rated output power | Safety standards | Standby current (power save mode) | Storage temperature/humidity range | Surge power (1 second) | Vibration resistance | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SP-1000-112A |
Available upon quote | Temperature load linked fan | 372×200×83mm | - | - | 50/60 (initial value) Hz±0.5% | 10.5~16.5Vdc | 100MΩ/500Vdc | 92% | 1,000~1,150VA (100~115%) | ≤1.5A | -20~+40℃ (rated load), +60℃ (40% load) | 100 (initial value) /110/115/120Vac±5% | Sine wave (distortion rate 5% or less) | Battery Input – AC Output: 2,121Vdc Battery Input – Chassis Ground: 500Vdc AC Output – Chassis Ground: 1,414Vdc | Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, output overtemperature/undertemperature | 12Vdc | 1,000VA±3% | - | <0.1A | -30~+70℃/10~95%RH (no condensation) | <1,750VA | 10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ | 3.26kg | |
SP-1000-124A |
Available upon quote | Temperature load linked fan | 372×200×83mm | - | - | 50/60 (initial value) Hz±0.5% | 21~33Vdc | 100MΩ/500Vdc | 93% | 1,000~1,150VA (100~115%) | ≤0.8A | -20~+40℃ (rated load), +60℃ (40% load) | 100 (initial value) /110/115/120Vac±5% | Sine wave (distortion rate 5% or less) | Battery Input – AC Output: 2,121Vdc Battery Input – Chassis Ground: 500Vdc AC Output – Chassis Ground: 1,414Vdc | Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, output overtemperature/undertemperature | 24Vdc | 1,000VA±3% | - | <0.06A | -30~+70℃/10~95%RH (no condensation) | <1,750VA | 10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ | 3.26kg | |
SP-1000-148A |
Available upon quote | Temperature load linked fan | 372×200×83mm | - | - | 50/60 (initial value) Hz±0.5% | 42~66Vdc | 100MΩ/500Vdc | 93% | 1,000~1,150VA (100~115%) | ≤0.5A | -20~+40℃ (rated load), +60℃ (40% load) | 100 (initial value) /110/115/120Vac±5% | Sine wave (distortion rate 5% or less) | Battery Input – AC Output: 2,121Vdc Battery Input – Chassis Ground: 500Vdc AC Output – Chassis Ground: 1,414Vdc | Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, output overtemperature/undertemperature | 48Vdc | 1,000VA±3% | - | <0.05A | -30~+70℃/10~95%RH (no condensation) | <1,750VA | 10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ | 3.26kg | |
SP-1000-212U |
Available upon quote | Temperature load linked fan | 372×200×83mm | CISPR 25; ISO 7637-2 | EN55022 class B; EN55024; EN61000-3-2,-3-3; EN61000-4-2, 3, 4, 5, 6, 8, 11 | 50 (initial value) /60Hz±0.5% | 10.5~16.5Vdc | 100MΩ/500Vdc | 92% | 1,000~1,150VA (100~115%) | ≤1.5A | -20~+40℃ (rated load), +60℃ (40% load) | 200 (initial value) /220/230/240Vac±3% | Sine wave (distortion rate 3% or less) | Battery Input – AC Output: 4,242Vdc Battery Input – Chassis Ground: 500Vdc AC Output – Chassis Ground: 2,121Vdc | Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, output overtemperature/undertemperature | 12Vdc | 1,000VA±3% | EN62368-1 | <0.1A | -30~+70℃/10~95%RH (no condensation) | <1,750VA | 10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ | 3.26kg | |
SP-1000-224U |
Available upon quote | Temperature load linked fan | 372×200×83mm | CISPR 25; ISO 7637-2 | EN55022 class B; EN55024; EN61000-3-2,-3-3; EN61000-4-2, 3, 4, 5, 6, 8, 11 | 50 (initial value) /60Hz±0.5% | 21~33Vdc | 100MΩ/500Vdc | 94% | 1,000~1,150VA (100~115%) | ≤0.8A | -20~+40℃ (rated load), +60℃ (40% load) | 200 (initial value) /220/230/240Vac±3% | Sine wave (distortion rate 3% or less) | Battery Input – AC Output: 4,242Vdc Battery Input – Chassis Ground: 500Vdc AC Output – Chassis Ground: 2,121Vdc | Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, output overtemperature/undertemperature | 24Vdc | 1,000VA±3% | EN62368-1 | <0.05A | -30~+70℃/10~95%RH (no condensation) | <1,750VA | 10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ | 3.26kg | |
SP-1000-248U |
Available upon quote | Temperature load linked fan | 372×200×83mm | CISPR 25; ISO 7637-2 | EN55022 class B; EN55024; EN61000-3-2,-3-3; EN61000-4-2, 3, 4, 5, 6, 8, 11 | 50 (initial value) /60Hz±0.5% | 42~66Vdc | 100MΩ/500Vdc | 94% | 1,000~1,150VA (100~115%) | ≤0.4A | -20~+40℃ (rated load), +60℃ (40% load) | 200 (initial value) /220/230/240Vac±3% | Sine wave (distortion rate 3% or less) | Battery Input – AC Output: 4,242Vdc Battery Input – Chassis Ground: 500Vdc AC Output – Chassis Ground: 2,121Vdc | Input undervoltage, input overvoltage, input reverse polarity connection (fuse), output overload, output short circuit, output overtemperature/undertemperature | 48Vdc | 1,000VA±3% | EN62368-1 | <0.05A | -30~+70℃/10~95%RH (no condensation) | <1,750VA | 10~500Hz, 2G 10min./1cycle, 60 minutes in each direction of XYZ | 3.26kg |
Click on the part number for more information about each product