All Categories
History
Product
Fanless sine wave inverter DIASINE® GD300Handling Company
Denryo Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Weight | Vibration resistance | Pressure resistance | Insulation resistance | Standard operating mode No-load current | Maximum output power (3 minutes) | Dimensions (L×W×H) | Rated output power | Rated input voltage | Safety standards | Frequency (switchable) | Operating humidity range | Operating temperature range | Efficiency (rated load) | Output voltage (switchable) | Output waveform | Cooling | Input voltage range | Protection circuit | Storage temperature/humidity range | Low consumption operating mode No-load current | Sleep current consumption | Standby current consumption | Surge power (3 seconds) | EMC standard |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GD300NA-112 |
Available upon quote |
0.9kg |
10~500Hz, 3G 10min./1cycle, 60 minutes in each direction of XYZ |
Battery Input – AC Output: 3.0kVac AC Output – Chassis Ground: 1.5kVac Battery Input – Chassis Ground: 1.5kVac |
>1,000MΩ/500Vdc/25℃/70%RH |
0.7A |
360VA |
234.0×146.5×44.0mm |
300VA |
12Vdc |
EN62368-1 |
50±0.1Hz (initial value) 50/60Hz |
20~90%RH (no condensation) |
-20~+40℃ (rated load), +60℃ (70% load) |
89% |
100 (initial value) /110/115/120Vac |
Sine wave (less than 3% distortion) |
Natural convection |
10.5~19.5Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection, output overload, output short circuit, output voltage abnormality, overtemperature |
-30~+70℃/10~95%RH (no condensation) |
0.6A |
1mA |
7mA |
420VA |
Immunity EN55024, Emission EN55032 |
|
GD300NA-124 |
Available upon quote |
0.9kg |
10~500Hz, 3G 10min./1cycle, 60 minutes in each direction of XYZ |
Battery Input – AC Output: 3.0kVac AC Output – Chassis Ground: 1.5kVac Battery Input – Chassis Ground: 1.5kVac |
>1,000MΩ/500Vdc/25℃/70%RH |
0.3A |
360VA |
234.0×146.5×44.0mm |
300VA |
24Vdc |
EN62368-1 |
50±0.1Hz (initial value) 50/60Hz |
20~90%RH (no condensation) |
-20~+40℃ (rated load), +60℃ (70% load) |
90% |
100 (initial value) /110/115/120Vac |
Sine wave (less than 3% distortion) |
Natural convection |
21~39Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection, output overload, output short circuit, output voltage abnormality, overtemperature |
-30~+70℃/10~95%RH (no condensation) |
0.2A |
3mA |
7mA |
420VA |
Immunity EN55024, Emission EN55032 |
|
GD300NA-148 |
Available upon quote |
0.9kg |
10~500Hz, 3G 10min./1cycle, 60 minutes in each direction of XYZ |
Battery Input – AC Output: 3.0kVac AC Output – Chassis Ground: 1.5kVac Battery Input – Chassis Ground: 1.5kVac |
>1,000MΩ/500Vdc/25℃/70%RH |
0.2A |
360VA |
234.0×146.5×44.0mm |
300VA |
48Vdc |
EN62368-1 |
50±0.1Hz (initial value) 50/60Hz |
20~90%RH (no condensation) |
-20~+40℃ (rated load), +60℃ (70% load) |
90% |
100 (initial value) /110/115/120Vac |
Sine wave (less than 3% distortion) |
Natural convection |
42~78Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection, output overload, output short circuit, output voltage abnormality, overtemperature |
-30~+70℃/10~95%RH (no condensation) |
0.1A |
2mA |
4mA |
420VA |
Immunity EN55024, Emission EN55032 |
|
GD300NU-212 |
Available upon quote |
1.0kg |
10~500Hz, 3G 10min./1cycle, 60 minutes in each direction of XYZ |
Battery Input – AC Output: 3.0kVac AC Output – Chassis Ground: 1.5kVac Battery Input – Chassis Ground: 1.5kVac |
>1,000MΩ/500Vdc/25℃/70%RH |
0.8A |
360VA |
234.0×146.5×44.0mm |
300VA |
12Vdc |
EN62368-1 |
50±0.1Hz (initial value) 50/60Hz |
20~90%RH (no condensation) |
-20~+40℃ (rated load), +60℃ (70% load) |
90% |
230 (initial value) /200/220/240Vac |
Sine wave (less than 3% distortion) |
Natural convection |
10.5~17Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection, output overload, output short circuit, output voltage abnormality, overtemperature |
-30~+70℃/10~95%RH (no condensation) |
0.7A |
2mA |
7mA |
420VA |
Immunity EN55024, Emission EN55032 |
|
GD300NU-224 |
Available upon quote |
1.0kg |
10~500Hz, 3G 10min./1cycle, 60 minutes in each direction of XYZ |
Battery Input – AC Output: 3.0kVac AC Output – Chassis Ground: 1.5kVac Battery Input – Chassis Ground: 1.5kVac |
>1,000MΩ/500Vdc/25℃/70%RH |
0.5A |
360VA |
234.0×146.5×44.0mm |
300VA |
24Vdc |
EN62368-1 |
50±0.1Hz (initial value) 50/60Hz |
20~90%RH (no condensation) |
-20~+40℃ (rated load), +60℃ (70% load) |
90% |
230 (initial value) /200/220/240Vac |
Sine wave (less than 3% distortion) |
Natural convection |
21~34Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection, output overload, output short circuit, output voltage abnormality, overtemperature |
-30~+70℃/10~95%RH (no condensation) |
0.4A |
4mA |
7mA |
420VA |
Immunity EN55024, Emission EN55032 |
|
GD300NU-248 |
Available upon quote |
1.0kg |
10~500Hz, 3G 10min./1cycle, 60 minutes in each direction of XYZ |
Battery Input – AC Output: 3.0kVac AC Output – Chassis Ground: 1.5kVac Battery Input – Chassis Ground: 1.5kVac |
>1,000MΩ/500Vdc/25℃/70%RH |
0.3A |
360VA |
234.0×146.5×44.0mm |
300VA |
48Vdc |
EN62368-1 |
50±0.1Hz (initial value) 50/60Hz |
20~90%RH (no condensation) |
-20~+40℃ (rated load), +60℃ (70% load) |
90% |
230 (initial value) /200/220/240Vac |
Sine wave (less than 3% distortion) |
Natural convection |
42~68Vdc |
Input undervoltage, input overvoltage, input reverse polarity connection, output overload, output short circuit, output voltage abnormality, overtemperature |
-30~+70℃/10~95%RH (no condensation) |
0.2A |
3mA |
4mA |
420VA |
Immunity EN55024, Emission EN55032 |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.