Constant temperature constant temperature device Enviros KCL-2000A/2000W typeHandling Company
Tokyo Rikakikai Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Cable hole | Convection method | Dehumidification method | Door packing material | External dimensions (mm) | External input/output | Freezer/refrigerant | Heater | Humidity adjustment range (accuracy) | Interior | Internal dimensions (mm) ・Capacity | Mass | Number of shelves included/shelf pitch | Observation window dimensions (mm) | Operating ambient temperature range | Other features | Power input/power voltage | Shelf plate load capacity, material, number of shelves | Temperature control range (accuracy) | Temperature/humidity control method | Temperature/humidity distribution accuracy | Water tank capacity |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KCL-2000A |
Available upon quote | 1 location (right side of main body) Inner diameter 40mm | Air jacket type natural convection method | Normal operation: automatic control (interval defrost mode) forced manual type (manual start, automatic stop/manual stop) | Silicon | 635 (800) W×777D×1,695H (including stand) 600 (800) W×777D×1,285H (product body) | RS-232C connection terminal Temperature/humidity recorder output terminal (temperature 1℃/mV, humidity 1%RH/mV) Output: -200 to 200mV alarm output terminal (contact/non-voltage type, contact capacity AC250V5A, normally OFF , ON when abnormal) | Air-cooled output 200W/R134a | Heater for heating 650W, heater for humidification 200W, 400W | ±0.2℃ (when set at 37℃) | Stainless | 500W×400D×700H・140L | Approximately 145kg | 2 sheets/40mm | - | 5~35℃ | Calibration of temperature and humidity display, external water supply, maintenance mode, forced drainage | 15A, 1.5kVA・AC100V 50/60Hz | Equal distribution Max.15kg/piece, stainless steel, 10 stages | Room temperature +5~60℃ | P.I.D control | Temperature gradient 2.5℃ (when set at 37℃) | Internal: Approx. 10L (removable from the front) External: Approx. 20L (one-touch socket connection) | |
KCL-2000W |
Available upon quote | 1 location (right side of main body) Inner diameter 40mm | Air jacket type natural convection method | Normal operation: automatic control (interval defrost mode) forced manual type (manual start, automatic stop/manual stop) | Silicon | 635 (800) W×777D×1,695H (including stand) 600 (800) W×777D×1,285H (product body) | RS-232C connection terminal Temperature/humidity recorder output terminal (temperature 1℃/mV, humidity 1%RH/mV) Output: -200 to 200mV alarm output terminal (contact/non-voltage type, contact capacity AC250V5A, normally OFF , ON when abnormal) | Air-cooled output 200W/R134a | Heater for heating 650W, heater for humidification 200W, 400W | ±0.2℃ (when set at 37℃) | Stainless | 500W×400D×700H・140L | Approximately 153kg | 2 sheets/40mm | 200W x 540H, quadruple glass (with heater) | 5~35℃ | Calibration of temperature and humidity display, external water supply, maintenance mode, forced drainage | 15A, 1.5kVA・AC100V 50/60Hz | Equal distribution Max.15kg/piece, stainless steel, 10 stages | Room temperature +5~60℃ | P.I.D control | Temperature gradient 2.5℃ (when set at 37℃) | Internal: Approx. 10L (removable from the front) External: Approx. 20L (one-touch socket connection) |
Click on the part number for more information about each product