All Categories
History
Response Rate
100.0%
Response Time
39.2hours
Product
Vacuum constant temperature dryer Vacuum dry oven VOS-210C/310C/452SD/602SD typeHandling Company
Tokyo Rikakikai Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power input/power voltage | Power utility | Mass | Observation window (mm) | Vacuum gauge | Temperature control range/accuracy | Temperature control/sensor | Time to reach temperature | Shelf board load capacity/material | Number of shelves included | Shelf pitch/number of shelves | Connection diameter | Exhaust gas material | Internal dimensions (mm)・Internal capacity | Safety features | External input/output | External dimensions (mm) | Heating method | Ultimate vacuum | Operating ambient temperature range | Program function | Heater | Inside door | Timer function |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
VOS-210S |
Available upon quote |
7.7A, 0.77kVA・AC100V 50/60Hz |
- |
Approximately 40kg |
160W×160H |
Bourdon tube type (scale 0~-0.1MPa) |
40~240℃・±1.5℃ (at240℃) |
P.I.D control with auto-tuning function, SSR output, platinum resistance thermometer (C type) / K thermocouple (SD type) |
Approximately 80 minutes |
Equal distribution Max.15kg/sheet/stainless steel plate |
2 pieces (Number of pieces that can be installed: 2 pieces) |
90mm・2 steps (fixed) |
Suction nozzle outer diameter 22mm hose port, purge nozzle outer diameter 22mm hose port (inner thread G1/4) |
Door packing: silicone, interior: stainless steel, glass, piping: copper, brass, fluororubber, aluminum |
192W×270D×192H・10L |
Self-diagnosis function (sensor alarm, overheat alarm, power outage alarm, door alarm, upper/lower limit temperature alarm, heater disconnection alarm), earth leakage/overcurrent breaker, variable independent overheating preventer (50 ~300℃) |
- |
355 (373) W×406 (431) D×580H |
Can heating |
133Pa (1Torr) |
5~35℃ |
1 step, 2 step repeat |
0.75kW |
Tempered glass 12mm thick |
Auto start, auto stop |
![]() |
VOS-310S |
Available upon quote |
12.5A, 1.25kVA・AC100V 50/60Hz |
- |
Approximately 60kg |
250W×250H |
Bourdon tube type (scale 0~-0.1MPa) |
40~240℃・±1.5℃ (at240℃) |
P.I.D control with auto-tuning function, SSR output, platinum resistance thermometer (C type) / K thermocouple (SD type) |
Approximately 80 minutes |
Equal distribution Max.15kg/sheet/stainless steel plate |
2 pieces (4 pieces that can be installed) |
71mm・4 steps (fixed) |
Suction nozzle outer diameter 22mm hose port, purge nozzle outer diameter 22mm hose port (inner thread G1/4) |
Door packing: silicone, interior: stainless steel, glass, piping: copper, brass, fluororubber, aluminum |
300W×300D×300H・27L |
Self-diagnosis function (sensor alarm, overheat alarm, power outage alarm, door alarm, upper/lower limit temperature alarm, heater disconnection alarm), earth leakage/overcurrent breaker, variable independent overheating preventer (50 ~300℃) |
- |
505 (523) W×545 (570) D×760H |
Can heating |
133Pa (1Torr) |
5~35℃ |
1 step, 2 step repeat |
1.2kW |
Tempered glass 12mm thick |
Auto start, auto stop |
![]() |
VOS-452SD |
Available upon quote |
10.75A, 2.15kVA・AC200V single phase 50/60Hz |
AC 200V single phase 15A capacity |
Approximately 135kg |
250W×250H |
Semiconductor pressure sensor (digital display) 0 to 1066hPa, minimum digit 1hPa |
40~210℃・±1.0℃ (at210℃) |
P.I.D control, SSR output, platinum resistance thermometer |
Approximately 80 minutes (40→210℃) |
Equal distribution Max.15kg/sheet/stainless steel plate |
3 pieces (6 pieces that can be installed) |
71mm・6 stages (fixed) |
Suction nozzle outer diameter 22mm hose port, purge nozzle outer diameter 16mm hose port (inner thread G1/4) |
Door packing: silicone, interior: stainless steel, glass, piping: stainless steel, glass fiber PTFE |
450W×450D×450H・91L |
Self-diagnosis function (temperature sensor abnormality, power recovery, door alarm, upper/lower limit temperature alarm, heater short, heater disconnection), earth leakage/overcurrent breaker, variable independent overheating preventer (50 to 270℃) |
USB communication terminal, recording output terminal/DC0~8,000mV, alarm output terminal/output: No-voltage a contact output (rated AC250V2A) |
655 (673) W×597 (605) D×905H |
Can heating |
1hPa (0.75Torr) |
5~35℃ |
2 step repeat, step operation (within 8 steps), 24 hour cycle |
2.1kW |
Tempered glass 15mm thick |
Auto start, auto stop |
![]() |
VOS-602SD |
Available upon quote |
12.75A, 2.55kVA/AC200V single phase 50/60Hz |
AC 200V single phase 15A capacity |
Approximately 345kg |
430W×430H |
Semiconductor pressure sensor (digital display) 0 to 1066hPa, minimum digit 1hPa |
40~200℃・±1.0℃ (at200℃) |
P.I.D control, SSR output, platinum resistance thermometer |
Approximately 110 minutes (40→ 200℃) |
Equal distribution Max.15kg/sheet/stainless steel plate |
4 pieces (6 pieces that can be installed) |
95mm・6 stages (fixed) |
Suction nozzle outer diameter 22mm hose port, purge nozzle outer diameter 16mm hose port (inner thread G1/4) |
Door packing: silicone, interior: stainless steel, glass, piping: stainless steel, glass fiber PTFE |
600W×600D×600H・216L |
Self-diagnosis function (temperature sensor abnormality, power recovery, door alarm, upper/lower limit temperature alarm, heater short, heater disconnection), earth leakage/overcurrent breaker, variable independent overheating preventer (50 to 260℃) |
USB communication terminal, recording output terminal/DC0~8,000mV, alarm output terminal/output: No-voltage a contact output (rated AC250V2A) |
860 (878) W×780 (785) D×1,720 (1,780) H |
Can heating |
1hPa (0.75Torr) |
5~35℃ |
2 step repeat, step operation (within 8 steps), 24 hour cycle |
2.5kW |
Tempered glass thickness 19mm |
Auto start, auto stop |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time