Low-temperature constant temperature water circulation system cooling thermo pump for open system CTP-1000/3000 type-CTP-1000
Low-temperature constant temperature water circulation system cooling thermo pump for open system CTP-1000/3000 type-CTP-3000
Low-temperature constant temperature water circulation system cooling thermo pump for open system CTP-1000/3000 type-Tokyo Rikakikai Co., Ltd.

Low-temperature constant temperature water circulation system cooling thermo pump for open system CTP-1000/3000 type
Tokyo Rikakikai Co., Ltd.


About This Product

■Circulate temperature-controlled water to the external open system path The built-in self-priming pump sucks the solution from the open water tank, cools it with the refrigerator and heater, adjusts the temperature, and supplies it. Aquariums up to 50L (CTP-3000 type) can be used. (Depends on usage conditions) If you want to circulate a small amount of water in a small aquarium, you can install an optional bypass line to circulate up to 1L/min. If you use the optional closed system circulation unit, it can also be circulated to the closed system route. The CTP-1000 model is a PSE (Electrical Appliance and Material Safety Law) certified product. ■Auto start operation After the set time t (maximum 99 hours and 59 minutes) has elapsed, the device starts operating and controls the temperature at the set temperature T1. ■Auto stop operation The device will stop operating after the set time t (maximum 99 hours and 59 minutes) has elapsed. ■2-step program operation At the set temperature T1, after the set time t1 has elapsed, it will shift to the set temperature T2, and after the set time t2 has elapsed, it will perform any desired repeat operation and then stop the device. ■Preventing heater failure It memorizes the cumulative operating time and sends an alarm to notify you of the estimated time to remove limestone attached to the heater. By using a scale cleaning agent (sold separately), you can remove scale attached to the heater and prevent heater failure.

  • Product

    Low-temperature constant temperature water circulation system cooling thermo pump for open system CTP-1000/3000 type

Share this product


150+ people viewing

Last viewed: 1 hour ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

2 Models of Low-temperature constant temperature water circulation system cooling thermo pump for open system CTP-1000/3000 type

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Aquarium material Circulation nozzle Circulation pump Cooling capacity (at liquid temperature) -10℃ Cooling capacity (at liquid temperature) 10℃ Cooling coil Cooling/circulation method External circulation ability (50/60Hz) External dimensions (mm) External input/output Freezer/refrigerant Heater Mass Operating ambient temperature range Power input/power voltage Safety features Temperature control Temperature control accuracy Temperature sensor Temperature setting range Temperature setting/display Timer function Water tank capacity
Low-temperature constant temperature water circulation system cooling thermo pump for open system CTP-1000/3000 type-Part Number-CTP-1000

CTP-1000

Available upon quote Stainless Outlet and return ports: 10.5mm outer diameter hose port Self-priming pump 60/80W (self-priming height 2m) 120W (100kcal/h) 200W (170kcal/h) Stainless Air-cooled/closed system directional circulation Maximum flow rate 7/7.5L/min, maximum head 4.5/6.0m (discharge pressure: 0.045MPa/0.06MPa) 324W×397 (437) D×482 (502) H External temperature sensor terminal, alarm output terminal: Voltage-free contact (b contact) output AC250V/DC30V Max.2A, recorder output terminal: DC1~4 (25mV/℃) Air-cooled output 300W/R134a 550W (stainless steel) Approximately 35kg 5~35℃ 10.5A, 1.05kVA・AC100V single phase 50/60Hz Self-diagnosis function (upper/lower limit temperature, power outage, refrigerator, sensor flow, watchdog, air-in, freezing, heater cleaning time), earth leakage/overcurrent breaker, refrigerator overload relay, refrigerator high pressure switch, independent over-rise preventer P.I.D control, SSR output ±0.2℃~ Platinum resistance thermometer Pt100Ω −10~80℃ Sheet key input/digital display, minimum digit 0.1℃ Auto start, auto stop, 2 step program Approximately 1L
Low-temperature constant temperature water circulation system cooling thermo pump for open system CTP-1000/3000 type-Part Number-CTP-3000

CTP-3000

Available upon quote Stainless Outlet and return ports: 16.5mm outer diameter hose port (G1/2) Self-priming pump 60/80W (self-priming height 2m) 230W (190kcal/h) 360W (310kcal/h) Stainless Air-cooled/closed system directional circulation Maximum flow rate 15/15.5L/min, maximum head 4.5/6.0m (discharge pressure: 0.045MPa/0.06MPa) 250W×480 (520) D×805 (825) H External temperature sensor terminal, alarm output terminal: Voltage-free contact (b contact) output AC250V/DC30V Max.2A, recorder output terminal: DC1~4 (25mV/℃) Air-cooled output 425W/R404A 700W (stainless steel) Approximately 44kg 5~35℃ 13A, 1.3kVA・AC100V single phase 50/60Hz Self-diagnosis function (upper/lower limit temperature, power outage, refrigerator, sensor flow, watchdog, air-in, freezing, heater cleaning time), earth leakage/overcurrent breaker, refrigerator overload relay, independent overheat prevention device (120℃ setting) ) P.I.D control, SSR output ±0.1℃~ Platinum resistance thermometer Pt100Ω −20~80℃ Sheet key input/digital display, minimum digit 0.1℃ Auto start, auto stop, 2 step program Approximately 1.5L

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Tokyo Rikakikai Co., Ltd.


View more products of Tokyo Rikakikai Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree