Product
Low-temperature constant temperature water circulation device Unithermo Ace Eco NCC-3000/3100 seriesHandling Company
Tokyo Rikakikai Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Attached functions | Compatible circulating water | Cooling capacity (at liquid temperature) -10℃ | Cooling capacity (at liquid temperature) 10℃ | Cooling capacity (at liquid temperature) 30℃ | Cooling/circulation method | External circulation capacity (50Hz) Maximum flow rate | External circulation capacity (50Hz) Maximum head | External circulation nozzle | External dimensions (mm) | External input/output | Freezer/refrigerant | Heater | Mass | Operating ambient temperature range | Power input | Power supply voltage | Safety features | Supply water | Temperature control accuracy | Temperature control method | Temperature sensor | Temperature setting range | Temperature setting/display | Water tank capacity |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NCC-3000A |
Available upon quote | Emergency stop button, variable independent overheating preventer | Water supply | 660W (567kcal/h) | 1,230W (1,057kcal/h) | 1,600W (1,376kcal/h) | Air-cooled/closed system directional circulation | 14.7L/min | 10.4m | Both discharge and return ports (Rc3/8 female thread) outer diameter 14mm hose port | 340W×440 (452) D×852H | Alarm output terminal: No-voltage contact (A contact) output 250V/DC30VMax.3A | Air-cooled output 550W/R410C | 2kW (stainless steel) | Approximately 53kg | 5~35℃ | 13.5A, 2.7kVA | AC200V single phase 50/60Hz | Temperature controller self-diagnosis function, refrigerator overload, sensor abnormality, refrigerator high pressure switch, refrigerator protection timer, float switch, SSR short circuit, heater disconnection, circulation pump thermal protector, antifreeze flow rate switch, etc. | - | ±0.1~0.2℃ | Inverter frequency control | Platinum resistance thermometer Pt100Ω | −10~80℃ | Sheet key input/digital display, minimum digit 0.1℃ | 3.6L (liquid volume 2.8L) | |
NCC-3000B |
Available upon quote | Emergency stop button, variable independent overheating preventer | Water supply | 500W (430kcal/h) | 1,070W (920kcal/h) | 1,440W (1,238kcal/h) | Air-cooled/closed system directional circulation | 21.8L/min | 19.4m | Both discharge and return ports (Rc3/8 female thread) outer diameter 14mm hose port | 340W×440 (452) D×852H | Alarm output terminal: No-voltage contact (A contact) output 250V/DC30VMax.3A | Air-cooled output 550W/R410C | 2kW (stainless steel) | Approximately 53kg | 5~35℃ | 14A, 2.8kVA | AC200V single phase 50/60Hz | Temperature controller self-diagnosis function, refrigerator overload, sensor abnormality, refrigerator high pressure switch, refrigerator protection timer, float switch, SSR short circuit, heater disconnection, circulation pump thermal protector, antifreeze flow rate switch, etc. | - | ±0.1~0.2℃ | Inverter frequency control | Platinum resistance thermometer Pt100Ω | −10~80℃ | Sheet key input/digital display, minimum digit 0.1℃ | 3.6L (liquid volume 2.8L) | |
NCC-3000C |
Available upon quote | Emergency stop button, variable independent overheating preventer | Clean water and pure water | 685W (589kcal/h) | 1,400W (1,204kcal/h) | 1,840W (1,582kcal/h) | Air-cooled/closed system directional circulation | 14.7L/min | 10.4m | Both discharge and return ports (Rc3/8 female thread) outer diameter 14mm hose port | 340W×440 (452) D×852H | Alarm output terminal: No-voltage contact (A contact) output 250V/DC30VMax.3A | Air-cooled output 550W/R410C | 2kW (stainless steel) | Approximately 55kg | 5~35℃ | 14A, 2.8kVA | AC200V single phase 50/60Hz | Temperature controller self-diagnosis function, refrigerator overload, sensor abnormality, refrigerator high pressure switch, refrigerator protection timer, float switch, SSR short circuit, heater disconnection, circulation pump thermal protector, antifreeze flow rate switch, etc. | - | ±0.1~0.2℃ | Inverter frequency control | Platinum resistance thermometer Pt100Ω | −10~80℃ | Sheet key input/digital display, minimum digit 0.1℃ | 3.6L (liquid volume 2.8L) | |
NCC-3000D |
Available upon quote | Emergency stop button, variable independent overheating preventer | Clean water and pure water | 600W (516kcal/h) | 1,240W (1,061kcal/h) | 1,680W (1,444kcal/h) | Air-cooled/closed system directional circulation | 21.8L/min | 19.4m | Both discharge and return ports (Rc3/8 female thread) outer diameter 14mm hose port | 340W×440 (452) D×852H | Alarm output terminal: No-voltage contact (A contact) output 250V/DC30VMax.3A | Air-cooled output 550W/R410C | 2kW (stainless steel) | Approximately 55kg | 5~35℃ | 14.5A, 2.9kVA | AC200V single phase 50/60Hz | Temperature controller self-diagnosis function, refrigerator overload, sensor abnormality, refrigerator high pressure switch, refrigerator protection timer, float switch, SSR short circuit, heater disconnection, circulation pump thermal protector, antifreeze flow rate switch, etc. | - | ±0.1~0.2℃ | Inverter frequency control | Platinum resistance thermometer Pt100Ω | −10~80℃ | Sheet key input/digital display, minimum digit 0.1℃ | 3.6L (liquid volume 2.8L) | |
NCC-3100A |
Available upon quote | Emergency stop button, variable independent overheating preventer | Water supply | 730W (627kcal/h) | 1,750W (1,505kcal/h) | 2,850W (2,451kcal/h) | Water cooling/closed system directional circulation | 14.7L/min | 10.4m | Both discharge and return ports (Rc3/8 female thread) outer diameter 14mm hose port | 340W×440 (452) D×852H | Alarm output terminal: No-voltage contact (A contact) output 250V/DC30VMax.3A | Water-cooled output 550W/R410C | 2kW (stainless steel) | Approximately 49kg | 5~35℃ | 13.5A, 2.7kVA | AC200V single phase 50/60Hz | Temperature controller self-diagnosis function, refrigerator overload, sensor abnormality, refrigerator high pressure switch, refrigerator protection timer, float switch, SSR short circuit, heater disconnection, circulation pump thermal protector, antifreeze flow rate switch, etc. | 35℃ or less, 30L/min or more (supply water inlet/outlet Rc1/2) | ±0.1~0.2℃ | Inverter frequency control | Platinum resistance thermometer Pt100Ω | −10~80℃ | Sheet key input/digital display, minimum digit 0.1℃ | 3.6L (liquid volume 2.8L) | |
NCC-3100B |
Available upon quote | Emergency stop button, variable independent overheating preventer | Water supply | 620W (533kcal/h) | 1,650W (1,419kcal/h) | 2,700W (2,322kcal/h) | Water cooling/closed system directional circulation | 21.8L/min | 19.4m | Both discharge and return ports (Rc3/8 female thread) outer diameter 14mm hose port | 340W×440 (452) D×852H | Alarm output terminal: No-voltage contact (A contact) output 250V/DC30VMax.3A | Water-cooled output 550W/R410C | 2kW (stainless steel) | Approximately 49kg | 5~35℃ | 14A, 2.8kVA | AC200V single phase 50/60Hz | Temperature controller self-diagnosis function, refrigerator overload, sensor abnormality, refrigerator high pressure switch, refrigerator protection timer, float switch, SSR short circuit, heater disconnection, circulation pump thermal protector, antifreeze flow rate switch, etc. | 35℃ or less, 30L/min or more (supply water inlet/outlet Rc1/2) | ±0.1~0.2℃ | Inverter frequency control | Platinum resistance thermometer Pt100Ω | −10~80℃ | Sheet key input/digital display, minimum digit 0.1℃ | 3.6L (liquid volume 2.8L) | |
NCC-3100C |
Available upon quote | Emergency stop button, variable independent overheating preventer | Clean water and pure water | 820W (705kcal/h) | 1,750W (1,505kcal/h) | 2,850W (2,451kcal/h) | Water cooling/closed system directional circulation | 14.7L/min | 10.4m | Both discharge and return ports (Rc3/8 female thread) outer diameter 14mm hose port | 340W×440 (452) D×852H | Alarm output terminal: No-voltage contact (A contact) output 250V/DC30VMax.3A | Water-cooled output 550W/R410C | 2kW (stainless steel) | Approximately 52kg | 5~35℃ | 13.5A, 2.7kVA | AC200V single phase 50/60Hz | Temperature controller self-diagnosis function, refrigerator overload, sensor abnormality, refrigerator high pressure switch, refrigerator protection timer, float switch, SSR short circuit, heater disconnection, circulation pump thermal protector, antifreeze flow rate switch, etc. | 35℃ or less, 30L/min or more (supply water inlet/outlet Rc1/2) | ±0.1~0.2℃ | Inverter frequency control | Platinum resistance thermometer Pt100Ω | −10~80℃ | Sheet key input/digital display, minimum digit 0.1℃ | 3.6L (liquid volume 2.8L) | |
NCC-3100D |
Available upon quote | Emergency stop button, variable independent overheating preventer | Clean water and pure water | 570W (490kcal/h) | 1,720W (1,479kcal/h) | 2,690W (2,313kcal/h) | Water cooling/closed system directional circulation | 21.8L/min | 19.4m | Both discharge and return ports (Rc3/8 female thread) outer diameter 14mm hose port | 340W×440 (452) D×852H | Alarm output terminal: No-voltage contact (A contact) output 250V/DC30VMax.3A | Water-cooled output 550W/R410C | 2kW (stainless steel) | Approximately 52kg | 5~35℃ | 14A, 2.8kVA | AC200V single phase 50/60Hz | Temperature controller self-diagnosis function, refrigerator overload, sensor abnormality, refrigerator high pressure switch, refrigerator protection timer, float switch, SSR short circuit, heater disconnection, circulation pump thermal protector, antifreeze flow rate switch, etc. | 35℃ or less, 30L/min or more (supply water inlet/outlet Rc1/2) | ±0.1~0.2℃ | Inverter frequency control | Platinum resistance thermometer Pt100Ω | −10~80℃ | Sheet key input/digital display, minimum digit 0.1℃ | 3.6L (liquid volume 2.8L) |
Click on the part number for more information about each product