Cooling water circulation system Cool Ace CA-2600C/2600F/2600F2 type-CA-2600C
Cooling water circulation system Cool Ace CA-2600C/2600F/2600F2 type-CA-2600F
Cooling water circulation system Cool Ace CA-2600C/2600F/2600F2 type-Tokyo Rikakikai Co., Ltd.

Cooling water circulation system Cool Ace CA-2600C/2600F/2600F2 type
Tokyo Rikakikai Co., Ltd.


About This Product

■CA-2600C type It has a built-in circulation pump with a discharge pressure of 0.2MPa, which is about the same as water pressure. Suitable when the pipe diameter is small or when there is a long lift or distance to the circulation destination. Equipped with an emergency stop button and a remote control terminal that can be controlled externally, it meets various needs in the industrial machinery field. Equipped with a bypass valve as standard, allowing adjustment of discharge pressure. It also helps protect pumps in flow paths with high piping resistance. ■CA-2600F・F2 type Can circulate pure water (electrical conductivity 0.01mS/m (0.1μS/cm) or higher) and silicone oil (at liquid temperature 10℃, viscosity 10mPa・S or lower). Suitable for applications that require thorough water quality control through ion exchange resin in the pipes. Since Barrel Silicone Fluid®, an inert and highly electrically insulating silicone oil, can be circulated, it is suitable for circulation sites where static electricity is averse, and for temperature control in semiconductor manufacturing equipment. The CA-2600F2 model has a built-in circulation pump with a discharge pressure of 0.2MPa, which is equivalent to water supply. Suitable for flow paths where the pipe diameter is small, there is a long lift or distance to the circulation destination, or where there are multiple elbows, gate valves, etc. in the pipe and pressure loss is expected to be high. ■Complete safety features ・Earth leakage/overcurrent breaker - Circulation pump thermal protector: The circulation pump will stop if it is overloaded (suction of foreign matter, high viscosity, rise in ambient temperature, etc.). Once the load is removed, operation will resume. ・Temperature rise alarm: An alarm will be output when the temperature inside the tank exceeds the set temperature + 5.0℃. Control continues. ・Temperature controller self-diagnosis function: Outputs an alarm when an abnormality in the temperature controller is detected. It will automatically recover when the cause of the abnormality is removed. ・Sensor abnormality ・Freezer overload ・Freezer high pressure switch ・Freezer protection timer - Circulating water pressure abnormal alarm (optional): When the circulating water pressure exceeds the upper limit setting, an abnormality is detected and an alarm is output.

  • Product

    Cooling water circulation system Cool Ace CA-2600C/2600F/2600F2 type

Share this product


180+ people viewing

Last viewed: 18 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

3 Models of Cooling water circulation system Cool Ace CA-2600C/2600F/2600F2 type

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Aquarium material Attached functions Compatible circulating water Cooling capacity (at liquid temperature) 10℃ Cooling capacity (at liquid temperature) 20℃ Cooling coil Cooling/circulation method External circulation ability (50/60Hz) External circulation nozzle External dimensions (mm) External input/output Freezer/refrigerant Mass Operating ambient temperature range Power input/power voltage Power utility Safety features Temperature control Temperature control accuracy Temperature setting range Temperature setting/display Water tank capacity Water tank dimensions (mm)
Cooling water circulation system Cool Ace CA-2600C/2600F/2600F2 type-Part Number-CA-2600C

CA-2600C

Available upon quote Stainless Flow control valve, bypass valve Clean water, ethylene glycol, Nybline®︎ 2,350W (2,021kcal/h) 3,000W (2,580kcal/h) Stainless Air-cooled/closed system directional circulation Maximum flow rate 27/30L/min, maximum head 20/28m Both discharge and return ports (Rc1/2 female thread) outer diameter 16mm hose port 450 (550) W×555D×1,010 (1,045) H Alarm output terminal: No-voltage a contact AC250V/DC30V Max.3A, remote control input terminal: No-voltage contact Air-cooled output 1.1kW/R407C Approximately 105kg 5~35℃ 11A, 2.2kVA・AC200V single phase 50/60Hz AC200V single phase 15A capacity Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector Capillary tube capacity switching control + refrigerator ON-OFF control ±2℃ −10~35℃ (without heater) Sheet key input/digital display 16. 5L (liquid volume 14L) Inner diameter 280W x 270H
Cooling water circulation system Cool Ace CA-2600C/2600F/2600F2 type-Part Number-CA-2600F

CA-2600F

Available upon quote Stainless Flow stop valve, bypass line set (optional) Tap water, pure water (electrical conductivity 0.01mS/m (0.1μS/cm) or higher) Silicone oil, Barrel Silicone Fluor® M-2 type, ethylene glycol, Nybline® 2,500W (2,150kcal/h) 3,000W (2,580kcal/h) Stainless Air-cooled/closed system directional circulation Maximum flow rate 13.5/16L/min, maximum head 10/14m Both discharge and return ports (Rc3/8 female thread) outer diameter 14mm hose port 450W×515D×1,236H Alarm output terminal: No-voltage a contact AC250V/DC30V Max.3A, remote control input terminal: No-voltage contact Air-cooled output 1.1kW/R407C Approximately 113kg 5~35℃ 11A, 2.2kVA・AC200V single phase 50/60Hz AC200V single phase 15A capacity Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector Capillary tube capacity switching control + refrigerator ON-OFF control ±2℃ 10~35℃ (without heater) Sheet key input/digital display 16. 5L (liquid volume 12.5L) Inner diameter 280W x 270H

CA-2600F2

Available upon quote Stainless Flow stop valve, bypass line set (optional) Tap water, pure water (electrical conductivity 0.01mS/m (0.1μS/cm) or higher) Silicone oil, Barrel Silicone Fluor® M-2 type, ethylene glycol, Nybline® 2,400W (2,064kcal/h) 2,900W (2,494kcal/h) Stainless Air-cooled/closed system directional circulation Maximum flow rate 17.5/18.5L/min, maximum head 20.5/25m Both discharge and return ports (Rc3/8 female thread) outer diameter 14mm hose port 450W×515D×1,236H Alarm output terminal: No-voltage a contact AC250V/DC30V Max.3A, remote control input terminal: No-voltage contact Air-cooled output 1.1kW/R407C Approximately 117kg 5~35℃ 11A, 2.2kVA・AC200V single phase 50/60Hz AC200V single phase 15A capacity Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector Capillary tube capacity switching control + refrigerator ON-OFF control ±2℃ 10~35℃ (without heater) Sheet key input/digital display 16. 5L (liquid volume 12.0L) Inner diameter 280W x 270H

Click on the part number for more information about each product