Cooling water circulation system Cool Ace CA-2610/2610S type-CA-2610S
Cooling water circulation system Cool Ace CA-2610/2610S type-Tokyo Rikakikai Co., Ltd.

Cooling water circulation system Cool Ace CA-2610/2610S type
Tokyo Rikakikai Co., Ltd.


About This Product

■Features This is a mid-power cooling water circulation device with a cooling capacity of 3,000W. It can be used to cool the heat generating parts of medium and large research equipment, as well as analytical equipment, machine tools, semiconductor manufacturing equipment, etc. It is equipped with various safety functions that can be used in a wide range of applications, and is also equipped with an external temperature sensor output terminal, a temperature recorder output terminal, and an alarm output to notify of refrigerator abnormalities, temperature abnormalities, sensor abnormalities, etc. The CA-2610S model is equipped with an emergency stop button and a remote control terminal that can be controlled externally, meeting the needs of the industrial machinery field. The temperature control range is wide from -10℃ to room temperature (up to 35℃), and the temperature control accuracy is ±2℃ or less, expanding the range of applications. The maximum lifting height is 9.5m as standard, up to 20m with the optional high-pressure pump (HPP type), and even up to 40m with a custom-made high discharge output type. An airtight lid (optional) allows circulation to an open system. We also manufacture oil circulation types, high discharge output types, and pure water circulation types as special orders. ■Complete safety features ・Earth leakage/overcurrent breaker - Circulation pump thermal protector: The circulation pump will stop if it is overloaded (suction of foreign matter, high viscosity, rise in ambient temperature, etc.). Once the load is removed, operation will resume. ・Temperature rise alarm: An alarm will be output when the temperature inside the tank exceeds the set temperature + 5.0℃. Control continues. ・Temperature controller self-diagnosis function: Outputs an alarm when an abnormality in the temperature controller is detected. It will automatically recover when the cause of the abnormality is removed. ・Sensor abnormality ・Freezer overload ・Freezer high pressure switch ・Freezer protection timer - Circulating water pressure abnormal alarm (optional): When the circulating water pressure exceeds the upper limit setting, an abnormality is detected and an alarm is output. - Circulating water flow rate drop alarm (optional): If the circulating water flow rate exceeds the lower limit set value, an abnormality is detected and an alarm is output. ■Equipped with various output terminals Equipped with an external temperature sensor terminal, a temperature recorder output terminal, and an alarm output terminal that outputs a variety of diagnostic information. The 2610S model is also equipped with a remote control terminal that allows you to remotely control the power supply, refrigerator, and circulation pump. External temperature sensor, output lead, and remote control lead are optional. ■Equipped with bypass valve A bypass valve is included as standard on the side of the device to prevent the mixing efficiency in the tank from decreasing even if it circulates through a flow path with high pressure loss.

  • Product

    Cooling water circulation system Cool Ace CA-2610/2610S type

Share this product


210+ people viewing

Last viewed: 7 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

2 Models of Cooling water circulation system Cool Ace CA-2610/2610S type

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Aquarium material Attached functions Circulation pump Cooling capacity (at liquid temperature) 10℃ Cooling capacity (at liquid temperature) 20℃ Cooling coil Cooling/circulation method Emergency stop button External circulation ability (50/60Hz) External circulation nozzle External dimensions (mm) External input/output Freezer/refrigerant Mass Operating ambient temperature range Power input/power voltage Power utility Safety features Temperature control Temperature control accuracy Temperature sensor Temperature setting range Temperature setting/display Type Water tank capacity Water tank dimensions (mm)

CA-2610

Available upon quote Stainless Bypass valve, flow control valve Magnet pump output 41/59W (50/60Hz) 2,500W (2,150kcal/h) 3,000W (2,580kcal/h) Stainless Air-cooled/closed system directional circulation - Maximum flow rate 23.5/27L/min, maximum head 9.5/13m (Blowout pressure: 0.09/0.13MPa) Both discharge and return ports (Rc1/2 female thread) outer diameter 16mm hose port 450 (555) W×515D×1,010 (1,025) H External temperature sensor terminal, temperature recorder output terminal, alarm output terminal Alarm items: Temperature rise lower limit, temperature controller self-diagnosis function, sensor abnormality, refrigerator overload, refrigerator high pressure switch, power outage alarm Air-cooled output 1.1kW/R407C Approximately 84kg 5~35℃ 10A, 2.0kVA・AC200V single phase 50/60Hz AC200V single phase 15A capacity Earth leak/overcurrent breaker, circulation pump thermal protector, temperature rise lower limit alarm, temperature controller self-diagnosis function, sensor abnormality, refrigerator overload, refrigerator high pressure switch, refrigerator protection timer, power outage alarm Capillary tube capacity switching control + refrigerator ON-OFF control ±2℃ or less Thermistor −10~35℃ (without heater) Sheet key input/digital display - 16. 5L (liquid volume 14L) Φ280W×270H
Cooling water circulation system Cool Ace CA-2610/2610S type-Part Number-CA-2610S

CA-2610S

Available upon quote Stainless Bypass valve, flow control valve Magnet pump output 41/59W (50/60Hz) 2,500W (2,150kcal/h) 3,000W (2,580kcal/h) Stainless Air-cooled/closed system directional circulation Standard equipment Maximum flow rate 23.5/27L/min, maximum head 9.5/13m (Blowout pressure: 0.09/0.13MPa) Both discharge and return ports (Rc1/2 female thread) outer diameter 16mm hose port 450 (555) W×515D×1,010 (1,025) H External temperature sensor terminal, temperature recorder output terminal, alarm output terminal Alarm items: lower limit of temperature rise, temperature controller self-diagnosis function, sensor abnormality, refrigerator overload, refrigerator high pressure switch Air-cooled output 1.1kW/R407C Approximately 84kg 5~35℃ 10A, 2.0kVA・AC200V single phase 50/60Hz AC200V single phase 15A capacity Earth leak/overcurrent breaker, circulation pump thermal protector, temperature rise lower limit alarm, temperature controller self-diagnosis function, sensor abnormality, refrigerator overload, refrigerator high pressure switch, refrigerator protection timer Capillary tube capacity switching control + refrigerator ON-OFF control ±2℃ or less Thermistor −10~35℃ (without heater) Sheet key input/digital display With emergency stop button 16. 5L (liquid volume 14L) Φ280W×270H

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Tokyo Rikakikai Co., Ltd.


View more products of Tokyo Rikakikai Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree