About This Product

■6 types that can be integrated into equipment

It can be used not only for cooling research equipment, but also for cooling the heat generating parts of machine tools, semiconductor manufacturing equipment, analysis and measurement equipment, etc. The temperature setting range is -20 to 30℃ (C, D, E type) and 10 to 30℃ (B, F, F2 type), making it suitable for a wide range of applications. The CA-1115B model is equipped with a SUS elbow (Rc3/8), and the CA-1115F/F2 models are equipped with a socket (Rc3/8), so they can also be connected to metal piping. CA-1115C/D/E types can also be equipped with nipples (Rc3/8) by removing the standard one-touch nozzle.

■Cooling the heat generating parts of industrial machinery

Heat generating parts of laser processing/welding machines, electrode parts of etching equipment, heating parts of magnetizing equipment, molding parts of resin molding machines, drawing parts of film/tube drawing equipment, liquefaction parts of solvent (fluorocarbon) recovery equipment, cleaning equipment , plating tank, kneading machine Cooling of the heat-generating parts of analysis and measurement equipment Light sources of electron microscopes, light sources of ICP emission spectrometers, heat-generating parts of spectrophotometers, diffusion pumps of mass spectrometers, heat sources of X-ray analyzers, constant temperature parts of autosamplers

■CA-1115B type compatible with circulation of pure water (electrical conductivity 0.1mS/m or more)

Pure water can be circulated. Suitable for applications that require thorough water quality control of circulating water and for temperature control management of semiconductor manufacturing equipment.

■CA-1115C type equipped with high pressure pump as standard

It can achieve a discharge pressure of 0.2MPa (2kgf/cm2), which is comparable to that of water supply, so it is suitable for circulation to the following channels. ・For channels with small pipe diameters ・When there is a difference in head to the circulation destination ・If there is a distance from the circulation device to the circulation destination ・For flow paths where there are multiple elbows, gate valves, etc. in the piping and pressure loss is expected to be high.

■CA-1115D type with alarm signal output terminal

Equipped with a function to output the alarm signal of the cooling water circulation system through a contact point. Upon receiving an alarm signal, it is possible to stop the device being circulated or turn on a commercially available patrol light.

■CA-1115E model equipped with two-stage water level drop detection function

Two float switches of different heights are installed to detect a drop in the water level in the tank in two stages. Float (1st stage) When approximately 8.5L of liquid remains in the tank, an alarm will be displayed (lamp will light) and control will continue. Float (2nd stage): When the remaining liquid volume in the tank is approximately 6.4L, an alarm is output as a contact and control is stopped.

  • Product

    Cooling water circulation system Cool Ace CA-1115 type series

Share this product


760+ people viewing

Last viewed: 17 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Cooling water circulation system Cool Ace CA-1115 type series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply voltage Power input Mass Temperature control accuracy Temperature setting range Temperature control Aquarium material Water tank dimensions (mm) Water tank capacity Compatible circulating water Safety features External circulation capacity (50/60Hz) maximum flow rate External circulation capacity (50/60Hz) Maximum head External circulation nozzle, both discharge and return ports External input/output External dimensions (mm) Cooling capacity (at liquid temperature) 20℃ Cooling capacity (at liquid temperature) 10℃ Cooling/circulation method Cooling coil Freezer/refrigerant Operating ambient temperature range Attached functions Cooling capacity (at liquid temperature) -10℃ Service outlet
Cooling water circulation system Cool Ace CA-1115 type series-Part Number-CA-1115B

CA-1115B

Available upon quote

AC100V 50/60Hz

11A, 1.1kVA

Approximately 43kg

±2℃

10~30℃ (without heater)

Freezer ON-OFF control

Stainless

Inner diameter 280W x 270H

16.5L (liquid volume 14L)

Clean water, pure water (electrical conductivity 0.1mS/m (1μS/cm) or higher)

Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector, service outlet fuse

16/18L/min

9.5/13m

Outer diameter 15mm
Hose port (Rc3/8)

-

340 (354) W×384D×851 (940)H

1,400W (1,204kcal/h)

1,200W (1,032kcal/h)

Air-cooled/closed system directional circulation

Stainless

Air-cooled output 650W/R407A

5~35℃

With ball valve, temperature display correction function

-

AC100V, Max4A 1 piece

Cooling water circulation system Cool Ace CA-1115 type series-Part Number-CA-1115C

CA-1115C

Available upon quote

AC100V 50/60Hz

13A, 1.3kVA

Approximately 47kg

±2℃

−20~30℃ (without heater)

Freezer ON-OFF control

Stainless

Inner diameter 280W x 270H

16.5L (liquid volume 14L)

Clean water, ethylene glycol, Nybrine®, Etabrine®

Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector, service outlet fuse

20/23L/min

20/28m

One-touch connector inner diameter 10mm, one-touch hose nozzle outer diameter 10mm

-

340 (354) W×384D×851 (940)H

1,400W (1,204kcal/h)

1,200W (1,032kcal/h)

Air-cooled/closed system directional circulation

Stainless

Air-cooled output 650W/R407A

5~35℃

With ball valve, temperature display correction function

560W (481kcal/h)

AC100V, Max2A 1 port

Cooling water circulation system Cool Ace CA-1115 type series-Part Number-CA-1115D

CA-1115D

Available upon quote

AC100V 50/60Hz

11A, 1.1kVA

Approximately 43kg

±2℃

−20~30℃ (without heater)

Freezer ON-OFF control

Stainless

Inner diameter 280W x 270H

16.5L (liquid volume 14L)

Clean water, ethylene glycol, Nybrine®, Etabrine®

Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector, service outlet fuse

12/14L/min

9.5/13m

One-touch connector inner diameter 10mm, one-touch hose nozzle outer diameter 10mm

Alarm output (no-voltage A contact), remote control input (no-voltage contact)

340 (354) W×384D×851 (940)H

1,400W (1,204kcal/h)

1,200W (1,032kcal/h)

Air-cooled/closed system directional circulation

Stainless

Air-cooled output 650W/R407A

5~35℃

With ball valve, temperature display correction function

650W (559kcal/h)

AC100V, Max4A 1 piece

Cooling water circulation system Cool Ace CA-1115 type series-Part Number-CA-1115E

CA-1115E

Available upon quote

AC100V 50/60Hz

11A, 1.1kVA

Approximately 44kg

±2℃

−20~30℃ (without heater)

Freezer ON-OFF control

Stainless

Inner diameter 280W x 270H

16.5L (liquid volume 14L)

Clean water, ethylene glycol, Nybrine®, Etabrine®

Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector, service outlet fuse, flow rate drop, water level drop

12/14L/min

9.5/13m

One-touch connector inner diameter 10mm, one-touch hose nozzle outer diameter 10mm

Alarm output (no-voltage A contact), remote control input (no-voltage contact)

340 (354) W×384D×851 (940)H

1,400W (1,204kcal/h)

1,200W (1,032kcal/h)

Air-cooled/closed system directional circulation

Stainless

Air-cooled output 650W/R407A

5~35℃

With ball valve, temperature display correction function, emergency stop button

650W (559kcal/h)

AC100V, Max4A 1 piece

Cooling water circulation system Cool Ace CA-1115 type series-Part Number-CA-1115F

CA-1115F

Available upon quote

AC100V 50/60Hz

13A, 1.3kVA

Approximately 54kg

±2℃

10~30℃ (without heater)

Freezer ON-OFF control

Stainless

Inner diameter 280W x 270H

16.5L (liquid volume 12.5L)

Tap water, pure water (electrical conductivity 0.01mS/m (0.1μS/cm) or higher) Silicone oil, Barrel Silicone Fluid®, ethylene glycol, Nibline®

Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector

13.5/16L/min

10/14m

Outer diameter 14mm
Hose port (Rc3/8)

Alarm output (no-voltage A contact)

340 (354) W×370D×988H

1,180W (1,014kcal/h)

1,000W (860kcal/h)

Air-cooled/closed system directional circulation

Stainless

Air-cooled output 650W/R407A

5~35℃

With ball valve, temperature display correction function, emergency stop button

- -

CA-1115F2

Available upon quote

AC100V 50/60Hz

13A, 1.3kVA

Approximately 58kg

±2℃

10~30℃ (without heater)

Freezer ON-OFF control

Stainless

Inner diameter 280W x 270H

16.5L (liquid volume 12.5L)

Tap water, pure water (electrical conductivity 0.01mS/m (0.1μS/cm) or higher) Silicone oil, Barrel Silicone Fluid®, ethylene glycol, Nibline®

Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector

1 7.5/18.5L/min

20.5/25m

Outer diameter 14mm
Hose port (Rc3/8)

Alarm output (no-voltage A contact)

340 (354) W×370D×988H

1,090W (937kcal/h)

915W (786kcal/h)

Air-cooled/closed system directional circulation

Stainless

Air-cooled output 650W/R407A

5~35℃

With ball valve, temperature display correction function, emergency stop button

- -

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Cooling Water Circulators Products

Other products of Tokyo Rikakikai Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Tokyo Rikakikai Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

39.2hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree