Cooling water circulation system Cool Ace CA-1115 type series-CA-1115B
Cooling water circulation system Cool Ace CA-1115 type series-CA-1115C
Cooling water circulation system Cool Ace CA-1115 type series-CA-1115D
Cooling water circulation system Cool Ace CA-1115 type series-CA-1115E
Cooling water circulation system Cool Ace CA-1115 type series-CA-1115F
Cooling water circulation system Cool Ace CA-1115 type series-Tokyo Rikakikai Co., Ltd.

Cooling water circulation system Cool Ace CA-1115 type series
Tokyo Rikakikai Co., Ltd.


About This Product

■6 types that can be integrated into equipment It can be used not only for cooling research equipment, but also for cooling the heat generating parts of machine tools, semiconductor manufacturing equipment, analysis and measurement equipment, etc. The temperature setting range is -20 to 30℃ (C, D, E type) and 10 to 30℃ (B, F, F2 type), making it suitable for a wide range of applications. The CA-1115B model is equipped with a SUS elbow (Rc3/8), and the CA-1115F/F2 models are equipped with a socket (Rc3/8), so they can also be connected to metal piping. CA-1115C/D/E types can also be equipped with nipples (Rc3/8) by removing the standard one-touch nozzle. ■Cooling the heat generating parts of industrial machinery Heat generating parts of laser processing/welding machines, electrode parts of etching equipment, heating parts of magnetizing equipment, molding parts of resin molding machines, drawing parts of film/tube drawing equipment, liquefaction parts of solvent (fluorocarbon) recovery equipment, cleaning equipment , plating tank, kneading machine Cooling of the heat-generating parts of analysis and measurement equipment Light sources of electron microscopes, light sources of ICP emission spectrometers, heat-generating parts of spectrophotometers, diffusion pumps of mass spectrometers, heat sources of X-ray analyzers, constant temperature parts of autosamplers ■CA-1115B type compatible with circulation of pure water (electrical conductivity 0.1mS/m or more) Pure water can be circulated. Suitable for applications that require thorough water quality control of circulating water and for temperature control management of semiconductor manufacturing equipment. ■CA-1115C type equipped with high pressure pump as standard It can achieve a discharge pressure of 0.2MPa (2kgf/cm2), which is comparable to that of water supply, so it is suitable for circulation to the following channels. ・For channels with small pipe diameters ・When there is a difference in head to the circulation destination ・If there is a distance from the circulation device to the circulation destination ・For flow paths where there are multiple elbows, gate valves, etc. in the piping and pressure loss is expected to be high. ■CA-1115D type with alarm signal output terminal Equipped with a function to output the alarm signal of the cooling water circulation system through a contact point. Upon receiving an alarm signal, it is possible to stop the device being circulated or turn on a commercially available patrol light. ■CA-1115E model equipped with two-stage water level drop detection function Two float switches of different heights are installed to detect a drop in the water level in the tank in two stages. Float (1st stage) When approximately 8.5L of liquid remains in the tank, an alarm will be displayed (lamp will light) and control will continue. Float (2nd stage): When the remaining liquid volume in the tank is approximately 6.4L, an alarm is output as a contact and control is stopped.

  • Product

    Cooling water circulation system Cool Ace CA-1115 type series

Share this product


550+ people viewing

Last viewed: 2 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

6 Models of Cooling water circulation system Cool Ace CA-1115 type series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Aquarium material Attached functions Compatible circulating water Cooling capacity (at liquid temperature) -10℃ Cooling capacity (at liquid temperature) 10℃ Cooling capacity (at liquid temperature) 20℃ Cooling coil Cooling/circulation method External circulation capacity (50/60Hz) Maximum head External circulation capacity (50/60Hz) maximum flow rate External circulation nozzle, both discharge and return ports External dimensions (mm) External input/output Freezer/refrigerant Mass Operating ambient temperature range Power input Power supply voltage Safety features Service outlet Temperature control Temperature control accuracy Temperature setting range Water tank capacity Water tank dimensions (mm)
Cooling water circulation system Cool Ace CA-1115 type series-Part Number-CA-1115B

CA-1115B

Available upon quote Stainless With ball valve, temperature display correction function Clean water, pure water (electrical conductivity 0.1mS/m (1μS/cm) or higher) - 1,200W (1,032kcal/h) 1,400W (1,204kcal/h) Stainless Air-cooled/closed system directional circulation 9.5/13m 16/18L/min Outer diameter 15mm
Hose port (Rc3/8)
340 (354) W×384D×851 (940)H - Air-cooled output 650W/R407A Approximately 43kg 5~35℃ 11A, 1.1kVA AC100V 50/60Hz Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector, service outlet fuse AC100V, Max4A 1 piece Freezer ON-OFF control ±2℃ 10~30℃ (without heater) 16.5L (liquid volume 14L) Inner diameter 280W x 270H
Cooling water circulation system Cool Ace CA-1115 type series-Part Number-CA-1115C

CA-1115C

Available upon quote Stainless With ball valve, temperature display correction function Clean water, ethylene glycol, Nybrine®, Etabrine® 560W (481kcal/h) 1,200W (1,032kcal/h) 1,400W (1,204kcal/h) Stainless Air-cooled/closed system directional circulation 20/28m 20/23L/min One-touch connector inner diameter 10mm, one-touch hose nozzle outer diameter 10mm 340 (354) W×384D×851 (940)H - Air-cooled output 650W/R407A Approximately 47kg 5~35℃ 13A, 1.3kVA AC100V 50/60Hz Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector, service outlet fuse AC100V, Max2A 1 port Freezer ON-OFF control ±2℃ −20~30℃ (without heater) 16.5L (liquid volume 14L) Inner diameter 280W x 270H
Cooling water circulation system Cool Ace CA-1115 type series-Part Number-CA-1115D

CA-1115D

Available upon quote Stainless With ball valve, temperature display correction function Clean water, ethylene glycol, Nybrine®, Etabrine® 650W (559kcal/h) 1,200W (1,032kcal/h) 1,400W (1,204kcal/h) Stainless Air-cooled/closed system directional circulation 9.5/13m 12/14L/min One-touch connector inner diameter 10mm, one-touch hose nozzle outer diameter 10mm 340 (354) W×384D×851 (940)H Alarm output (no-voltage A contact), remote control input (no-voltage contact) Air-cooled output 650W/R407A Approximately 43kg 5~35℃ 11A, 1.1kVA AC100V 50/60Hz Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector, service outlet fuse AC100V, Max4A 1 piece Freezer ON-OFF control ±2℃ −20~30℃ (without heater) 16.5L (liquid volume 14L) Inner diameter 280W x 270H
Cooling water circulation system Cool Ace CA-1115 type series-Part Number-CA-1115E

CA-1115E

Available upon quote Stainless With ball valve, temperature display correction function, emergency stop button Clean water, ethylene glycol, Nybrine®, Etabrine® 650W (559kcal/h) 1,200W (1,032kcal/h) 1,400W (1,204kcal/h) Stainless Air-cooled/closed system directional circulation 9.5/13m 12/14L/min One-touch connector inner diameter 10mm, one-touch hose nozzle outer diameter 10mm 340 (354) W×384D×851 (940)H Alarm output (no-voltage A contact), remote control input (no-voltage contact) Air-cooled output 650W/R407A Approximately 44kg 5~35℃ 11A, 1.1kVA AC100V 50/60Hz Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector, service outlet fuse, flow rate drop, water level drop AC100V, Max4A 1 piece Freezer ON-OFF control ±2℃ −20~30℃ (without heater) 16.5L (liquid volume 14L) Inner diameter 280W x 270H
Cooling water circulation system Cool Ace CA-1115 type series-Part Number-CA-1115F

CA-1115F

Available upon quote Stainless With ball valve, temperature display correction function, emergency stop button Tap water, pure water (electrical conductivity 0.01mS/m (0.1μS/cm) or higher) Silicone oil, Barrel Silicone Fluid®, ethylene glycol, Nibline® - 1,000W (860kcal/h) 1,180W (1,014kcal/h) Stainless Air-cooled/closed system directional circulation 10/14m 13.5/16L/min Outer diameter 14mm
Hose port (Rc3/8)
340 (354) W×370D×988H Alarm output (no-voltage A contact) Air-cooled output 650W/R407A Approximately 54kg 5~35℃ 13A, 1.3kVA AC100V 50/60Hz Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector - Freezer ON-OFF control ±2℃ 10~30℃ (without heater) 16.5L (liquid volume 12.5L) Inner diameter 280W x 270H

CA-1115F2

Available upon quote Stainless With ball valve, temperature display correction function, emergency stop button Tap water, pure water (electrical conductivity 0.01mS/m (0.1μS/cm) or higher) Silicone oil, Barrel Silicone Fluid®, ethylene glycol, Nibline® - 915W (786kcal/h) 1,090W (937kcal/h) Stainless Air-cooled/closed system directional circulation 20.5/25m 1 7.5/18.5L/min Outer diameter 14mm
Hose port (Rc3/8)
340 (354) W×370D×988H Alarm output (no-voltage A contact) Air-cooled output 650W/R407A Approximately 58kg 5~35℃ 13A, 1.3kVA AC100V 50/60Hz Earth leakage/overcurrent breaker, refrigerator high pressure switch, overload relay holding circuit, refrigerator protection timer, temperature controller self-diagnosis function, circulation pump thermal protector - Freezer ON-OFF control ±2℃ 10~30℃ (without heater) 16.5L (liquid volume 12.5L) Inner diameter 280W x 270H

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Tokyo Rikakikai Co., Ltd.


View more products of Tokyo Rikakikai Co., Ltd.

About Company Handling This Product