All Categories

History

Multi-function combination SC3-SC3-10S
Multi-function combination SC3-Combum Co., Ltd.

Multi-function combination SC3
Combum Co., Ltd.

Combum Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

169.7hours


About This Product

■Flexible combination selection possible

Freely set combinations based on the presence or absence of filters and sensors

■Quick and reliable work removal

Equipped with a sealing valve that perfectly blows out the breaking air when the workpiece is removed *Maximum 200L/min (ANR)

■Reducing air consumption

Air reduction of over 50% can be achieved by installing a sensor with a new energy saving control function. *When equipped with energy saving sensor

■Holds work during emergency stop

- Equipped with a self-holding solenoid valve to maintain vacuum generation even during emergency stoppages such as power outages. ・Prevents work from falling.

■Smallest body in class (compared to our company)

Ideal for mounting on robots, etc.

■Can operate at 0.25MPa Multi-functional design with single nozzle and multi-flow rate nozzle

・Vacuum level -82kPa at minimum 0.25MPa ・Maximum suction flow rate of 90L/min (ANR) at 0.5MPa

■Pressure sensor type (installed sensor)

・V9N (MPS-9): Pressure: Vacuum, Display: Digital, Switch output: NPN 1 point, Analog output: DC1 to 5V, Input use: None ・10N (MPS-10): Pressure: Compound pressure, Display: Digital, Switch output: NPN 1 point, Analog output: DC1 to 5V, Input use: Sink ・ZZ: No sensor

■Exhaust method

・S: Silencer exhaust ・P: Individual exhaust ・C: Centralized exhaust (when manifold is selected)

■Port size

T: Supply port Φ8, vacuum port Φ8 R: Supply port Rc1/4, vacuum port Rc1/4 N: Supply port 1/4-27 NPT, vacuum port 1/4-27 NPT G: Supply port G1/4, vacuum port G1/4 *Other model numbers are available.

  • Product

    Multi-function combination SC3

Share this product


270+ people viewing

Last viewed: 49 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Multi-function combination SC3

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Mass Single unit (full set) Mass 1 manifold (full set) Air consumption (ℓ/min (ANR) ) Vacuum break flow rate (ℓ/min (ANR) ) Body type Exhaust method Sealing valve/check valve Rated pressure (MPa) Ambient temperature (℃) Suction flow rate Individual port exhaust (ℓ/min (ANR) ) Ultimate vacuum pressure (kPa) Supply air flow path condition Fluid used Working pressure range (MPa) Manifold stations Manifold Filter Nozzle type
Multi-function combination SC3-Part Number-SC3-10S

SC3-10S

Available upon quote

255

378

48

200 (when equipped with a sealing plug)

S: Single type
M: Manifold type

S: Silencer exhaust
P: Individual exhaust
C: Centralized exhaust (when manifold is selected)

C: With sealing valve, with check valve
D: With check valve, without check valve
E: Without sealing valve, with check valve

0.5

0~55 (no freezing)

23 (25)

-90

A: Always open
B: Normally closed
w: Self-holding If a self-holding solenoid valve is selected, the energy saving function of the pressure sensor cannot be used.

Oil-free compressed air

0.2~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

F: with
Z: None

0.5MPa

Multi-function combination SC3-Part Number-SC3-13S

SC3-13S

Available upon quote

255

378

74

200 (when equipped with a sealing plug)

S: Single type
M: Manifold type

S: Silencer exhaust
P: Individual exhaust
C: Centralized exhaust (when manifold is selected)

C: With sealing valve, with check valve
D: With check valve, without check valve
E: Without sealing valve, with check valve

0.5

0~55 (no freezing)

38 (42)

-89

A: Always open
B: Normally closed
w: Self-holding If a self-holding solenoid valve is selected, the energy saving function of the pressure sensor cannot be used.

Oil-free compressed air

0.2~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

F: with
Z: None

0.5MPa

Multi-function combination SC3-Part Number-SC3-15S

SC3-15S

Available upon quote

255

378

100

200 (when equipped with a sealing plug)

S: Single type
M: Manifold type

S: Silencer exhaust
P: Individual exhaust
C: Centralized exhaust (when manifold is selected)

C: With sealing valve, with check valve
D: With check valve, without check valve
E: Without sealing valve, with check valve

0.5

0~55 (no freezing)

57 (60)

-91

A: Always open
B: Normally closed
w: Self-holding If a self-holding solenoid valve is selected, the energy saving function of the pressure sensor cannot be used.

Oil-free compressed air

0.2~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

F: with
Z: None

0.5MPa

Multi-function combination SC3-Part Number-SC3-10L

SC3-10L

Available upon quote

255

378

48

200 (when equipped with a sealing plug)

S: Single type
M: Manifold type

S: Silencer exhaust
P: Individual exhaust
C: Centralized exhaust (when manifold is selected)

C: With sealing valve, with check valve
D: With check valve, without check valve
E: Without sealing valve, with check valve

0.5

0~55 (no freezing)

43 (45)

-65

A: Always open
B: Normally closed
w: Self-holding If a self-holding solenoid valve is selected, the energy saving function of the pressure sensor cannot be used.

Oil-free compressed air

0.2~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

F: with
Z: None

0.5MPa

Multi-function combination SC3-Part Number-SC3-13L

SC3-13L

Available upon quote

255

378

74

200 (when equipped with a sealing plug)

S: Single type
M: Manifold type

S: Silencer exhaust
P: Individual exhaust
C: Centralized exhaust (when manifold is selected)

C: With sealing valve, with check valve
D: With check valve, without check valve
E: Without sealing valve, with check valve

0.5

0~55 (no freezing)

66 (78)

-57

A: Always open
B: Normally closed
w: Self-holding If a self-holding solenoid valve is selected, the energy saving function of the pressure sensor cannot be used.

Oil-free compressed air

0.2~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

F: with
Z: None

0.5MPa

Multi-function combination SC3-Part Number-SC3-15L

SC3-15L

Available upon quote

255

378

100

200 (when equipped with a sealing plug)

S: Single type
M: Manifold type

S: Silencer exhaust
P: Individual exhaust
C: Centralized exhaust (when manifold is selected)

C: With sealing valve, with check valve
D: With check valve, without check valve
E: Without sealing valve, with check valve

0.5

0~55 (no freezing)

74 (90)

-63

A: Always open
B: Normally closed
w: Self-holding If a self-holding solenoid valve is selected, the energy saving function of the pressure sensor cannot be used.

Oil-free compressed air

0.2~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

F: with
Z: None

0.5MPa

Multi-function combination SC3-Part Number-SC3-10R

SC3-10R

Available upon quote

255

378

47

200 (when equipped with a sealing plug)

S: Single type
M: Manifold type

S: Silencer exhaust
P: Individual exhaust
C: Centralized exhaust (when manifold is selected)

C: With sealing valve, with check valve
D: With check valve, without check valve
E: Without sealing valve, with check valve

0.25

0~55 (no freezing)

20 (21)

-86

A: Always open
B: Normally closed
w: Self-holding If a self-holding solenoid valve is selected, the energy saving function of the pressure sensor cannot be used.

Oil-free compressed air

0.2~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

F: with
Z: None

0.25MPa

Multi-function combination SC3-Part Number-SC3-13R

SC3-13R

Available upon quote

255

378

70

200 (when equipped with a sealing plug)

S: Single type
M: Manifold type

S: Silencer exhaust
P: Individual exhaust
C: Centralized exhaust (when manifold is selected)

C: With sealing valve, with check valve
D: With check valve, without check valve
E: Without sealing valve, with check valve

0.35

0~55 (no freezing)

30 (33)

-88

A: Always open
B: Normally closed
w: Self-holding If a self-holding solenoid valve is selected, the energy saving function of the pressure sensor cannot be used.

Oil-free compressed air

0.2~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

F: with
Z: None

0.35MPa

Multi-function combination SC3-Part Number-SC3-15R

SC3-15R

Available upon quote

255

378

100

200 (when equipped with a sealing plug)

S: Single type
M: Manifold type

S: Silencer exhaust
P: Individual exhaust
C: Centralized exhaust (when manifold is selected)

C: With sealing valve, with check valve
D: With check valve, without check valve
E: Without sealing valve, with check valve

0.35

0~55 (no freezing)

50 (54)

-90

A: Always open
B: Normally closed
w: Self-holding If a self-holding solenoid valve is selected, the energy saving function of the pressure sensor cannot be used.

Oil-free compressed air

0.2~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

F: with
Z: None

0.35MPa

Multi-function combination SC3-Part Number-SC3-07X

SC3-07X

Available upon quote

255

378

Twenty two

200 (when equipped with a sealing plug)

S: Single type
M: Manifold type

S: Silencer exhaust
P: Individual exhaust
C: Centralized exhaust (when manifold is selected)

C: With sealing valve, with check valve
D: With check valve, without check valve
E: Without sealing valve, with check valve

0.5

0~55 (no freezing)

37 (48)

-90

A: Always open
B: Normally closed
w: Self-holding If a self-holding solenoid valve is selected, the energy saving function of the pressure sensor cannot be used.

Oil-free compressed air

0.2~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive

F: with
Z: None

0.5MPa

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Vacuum Ejector Products

Other products of Combum Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Combum Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

169.7hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree