Energy saving smart combination SC1-SC1-S-B
Energy saving smart combination SC1-Combum Co., Ltd.

Energy saving smart combination SC1
Combum Co., Ltd.

Combum Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

169.7hours


About This Product

■Significant reduction in noise value (up to 12% reduction)

This results in an average 8.7dB reduction in exhaust noise.

■Leads to lighter weight and smaller size of the entire device

・Compact structure: body width 10mm ・Body gravity 75g (single unit/no sensor)

■Holds work during emergency stop

-Equipped with a self-holding stagnant surface that maintains vacuum generation even during emergency shutdowns such as power outages. ・Prevents work from falling

■In addition to silencer exhaust, central exhaust can also be selected.

Exhaust air is discharged outside using centralized exhaust → Use in a clean room or other environment.

■Pressure sensor type (installed sensor)

・V8 (MPS-V8): Pressure: Vacuum, Display: None, Switch output: None, Analog output: DC1 to 5V, Input use: None ・V9 (MPS-9): Pressure: Vacuum, Display: None, Switch output: NPN 1 point, Analog output: DC1 to 5V, Input use: None ・V9P (MPS-9): Pressure: Vacuum, Display: Digital, Switch output: 1 PNP point, Analog output: DC1 to 5V, Input use: None ・10 (MPS-10): Pressure: Compound pressure, Display: Digital, Switch output: NPN 1 point, Analog output: DC1 to 5V, Input use: Sink ・10P (MPS-10): Pressure: compound pressure, display: digital, switch output: 1 PNP point, analog output: DC1 to 5V, input use: sink ・10PS (MPS-10): Pressure: compound pressure, display: digital, switch output: 1 PNP point, analog output: DC1 to 5V, input use: source ・ZZ: No sensor

■Exhaust

S: Silencer exhaust, C: Centralized exhaust (Note 1 Note 2) Note 1: When using a manifold type with centralized exhaust, select one with a check valve. If you use a manifold with SC1 that is not equipped with a check valve, there is a possibility that the breaking air will get around to the vacuum port side. Note 2: When selecting the (S) nozzle for the single unit type, there is no central exhaust option.

  • Product

    Energy saving smart combination SC1

Share this product


340+ people viewing

Last viewed: 12 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Energy saving smart combination SC1

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Noise value Vacuum port open (dB) Noise value Vacuum port occlusion (dB) Solenoid valve Non-return valve Air consumption (ℓ/min (ANR) ) Vacuum break flow rate (ℓ/min (ANR) ) Number of units Body type Rated pressure (MPa) Ambient temperature (℃) Suction flow rate (ℓ/min (ANR) ) Ultimate vacuum pressure (kPa) Supply air flow path condition Fluid used Working pressure range (MPa) Manifold stations Number of block plates Nozzle type Set direction
Energy saving smart combination SC1-Part Number-SC1-S-B

SC1-S-B

Available upon quote

59.3

50.6

S: Normally closed
W: Self-holding Note) If you select a self-holding solenoid valve, the energy saving function of the pressure sensor cannot be used.

C: With check valve
N: No check valve

10

20 (at:0.2)

1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units
6: 6 units

S: Single type

0.18

0~55 (no freezing)

10

-83

Normally closed/self-maintaining

Oil-free compressed air

0.1~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive
6: 6 consecutive

0: None
1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units

B: 0.18MPa

R: Right justified
L: Left justified
No symbol: Same number of manifolds and main units

Energy saving smart combination SC1-Part Number-SC1-S-X

SC1-S-X

Available upon quote

61.9

52.6

S: Normally closed
W: Self-holding Note) If you select a self-holding solenoid valve, the energy saving function of the pressure sensor cannot be used.

C: With check valve
N: No check valve

10

40 (at:0.5)

1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units
6: 6 units

S: Single type

0.5

0~55 (no freezing)

8.5

-90

Normally closed/self-maintaining

Oil-free compressed air

0.1~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive
6: 6 consecutive

0: None
1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units

X: 0.5MPa

R: Right justified
L: Left justified
No symbol: Same number of manifolds and main units

Energy saving smart combination SC1-Part Number-SC1-S-1S

SC1-S-1S

Available upon quote

75.9

74.6

S: Normally closed
W: Self-holding Note) If you select a self-holding solenoid valve, the energy saving function of the pressure sensor cannot be used.

C: With check valve
N: No check valve

50


40 (at:0.5)

1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units
6: 6 units

S: Single type

0.5

0~55 (no freezing)

20

-87

Normally closed/self-maintaining

Oil-free compressed air

0.1~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive
6: 6 consecutive

0: None
1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units

1S: 0.5MPa

R: Right justified
L: Left justified
No symbol: Same number of manifolds and main units

Energy saving smart combination SC1-Part Number-SC1-M-B

SC1-M-B

Available upon quote

59.3

50.6

S: Normally closed
W: Self-holding Note) If you select a self-holding solenoid valve, the energy saving function of the pressure sensor cannot be used.

C: With check valve
N: No check valve

10

20 (at:0.2)

1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units
6: 6 units

M: Manifold

0.18

0~55 (no freezing)

10

-83

Normally closed/self-maintaining

Oil-free compressed air

0.1~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive
6: 6 consecutive

0: None
1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units

B: 0.18MPa

R: Right justified
L: Left justified
No symbol: Same number of manifolds and main units

Energy saving smart combination SC1-Part Number-SC1-M-X

SC1-M-X

Available upon quote

61.9

52.6

S: Normally closed
W: Self-holding Note) If you select a self-holding solenoid valve, the energy saving function of the pressure sensor cannot be used.

C: With check valve
N: No check valve

10

40 (at:0.5)

1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units
6: 6 units

M: Manifold

0.5

0~55 (no freezing)

8.5

-90

Normally closed/self-maintaining

Oil-free compressed air

0.1~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive
6: 6 consecutive

0: None
1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units

X: 0.5MPa

R: Right justified
L: Left justified
No symbol: Same number of manifolds and main units

Energy saving smart combination SC1-Part Number-SC1-M-1S

SC1-M-1S

Available upon quote

75.9

74.6

S: Normally closed
W: Self-holding Note) If you select a self-holding solenoid valve, the energy saving function of the pressure sensor cannot be used.

C: With check valve
N: No check valve

50


40 (at:0.5)

1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units
6: 6 units

M: Manifold

0.5

0~55 (no freezing)

20

-87

Normally closed/self-maintaining

Oil-free compressed air

0.1~0.55

1: 1 series
2: 2 consecutive
3: 3 consecutive
4: 4 consecutive
5: 5 consecutive
6: 6 consecutive

0: None
1:1 unit
2: 2 units
3: 3 units
4: 4 units
5: 5 units

1S: 0.5MPa

R: Right justified
L: Left justified
No symbol: Same number of manifolds and main units

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Vacuum Ejector Products

Other products of Combum Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Combum Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

169.7hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree