Beam type load cell LUB-BHandling Company
KYOWA ELECTRONIC INSTRUMENTS CO., LTDCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Nonlinearity | Temperature effect at zero point | Mass | Allowable overload | Allowable temperature range | Allowable applied voltage | Repeatability | Temperature compensation range | Recommended applied voltage | Rated capacity | Rated output | Natural frequency | Sold separately | Output resistance | Temperature effect on output | Input resistance | Protection class | Hysteresis | Cable |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For LUB-5KB 50N |
Available upon quote |
Within ±0.03%RO |
Within ±0.003%RO/℃ |
Approx. 350g (excluding cable) |
150% |
-20~70℃ |
20V AC or DC |
0.03%RO or less |
-10~60℃ |
1~12V AC or DC |
50N |
2mV/V (4,000×10^-6 strain) ±0.3% |
Approximately 250Hz |
Load receiver CA-2B |
350Ω±2Ω |
Within ±0.003%/℃ |
435Ω±60Ω |
IP67 (JIS C 0920) |
Within ±0.03%RO |
0.3mm2, 4-core shielded chloroprene 3m |
|
For LUB-10KB 100N |
Available upon quote |
Within ±0.03%RO |
Within ±0.003%RO/℃ |
Approx. 350g (excluding cable) |
150% |
-20~70℃ |
20V AC or DC |
0.03%RO or less |
-10~60℃ |
1~12V AC or DC |
100N |
2mV/V (4,000×10^-6 strain) ±0.3% |
Approximately 350Hz |
Load receiver CA-2B |
350Ω±2Ω |
Within ±0.003%/℃ |
435Ω±60Ω |
IP67 (JIS C 0920) |
Within ±0.03%RO |
0.3mm2, 4-core shielded chloroprene 3m |
|
For LUB-20KB 200N |
Available upon quote |
Within ±0.03%RO |
Within ±0.003%RO/℃ |
Approx. 350g (excluding cable) |
150% |
-20~70℃ |
20V AC or DC |
0.03%RO or less |
-10~60℃ |
1~12V AC or DC |
200N |
2mV/V (4,000×10^-6 strain) ±0.3% |
Approximately 500Hz |
Load receiver CA-2B |
350Ω±2Ω |
Within ±0.003%/℃ |
435Ω±60Ω |
IP67 (JIS C 0920) |
Within ±0.03%RO |
0.3mm2, 4-core shielded chloroprene 3m |
|
For LUB-30KB 300N |
Available upon quote |
Within ±0.03%RO |
Within ±0.003%RO/℃ |
Approx. 350g (excluding cable) |
150% |
-20~70℃ |
20V AC or DC |
0.03%RO or less |
-10~60℃ |
1~12V AC or DC |
300N |
2mV/V (4,000×10^-6 strain) ±0.3% |
Approximately 650Hz |
Load receiver CA-2B |
350Ω±2Ω |
Within ±0.003%/℃ |
435Ω±60Ω |
IP67 (JIS C 0920) |
Within ±0.03%RO |
0.3mm2, 4-core shielded chloroprene 3m |
|
For LUB-50KB 500N |
Available upon quote |
Within ±0.03%RO |
Within ±0.003%RO/℃ |
Approx. 350g (excluding cable) |
150% |
-20~70℃ |
20V AC or DC |
0.03%RO or less |
-10~60℃ |
1~12V AC or DC |
500N |
2mV/V (4,000×10^-6 strain) ±0.3% |
Approximately 800Hz |
Load receiver CA-2B |
350Ω±2Ω |
Within ±0.003%/℃ |
435Ω±60Ω |
IP67 (JIS C 0920) |
Within ±0.03%RO |
0.3mm2, 4-core shielded chloroprene 3m |
|
LUB-100KB for 1kN |
Available upon quote |
Within ±0.05%RO |
Within ±0.003%RO/℃ |
Approx. 350g (excluding cable) |
150% |
-20~70℃ |
20V AC or DC |
0.03%RO or less |
-10~60℃ |
1~12V AC or DC |
1kN |
2mV/V (4,000×10^-6 strain) ±0.3% |
Approximately 1.8kHz |
Load receiver CA-2B |
350Ω±2Ω |
Within ±0.003%/℃ |
400Ω±50Ω |
IP67 (JIS C 0920) |
Within ±0.05%RO |
0.3mm2, 4-core shielded chloroprene 5m |
|
LUB-200KB for 2kN |
Available upon quote |
Within ±0.05%RO |
Within ±0.003%RO/℃ |
Approx. 350g (excluding cable) |
150% |
-20~70℃ |
20V AC or DC |
0.03%RO or less |
-10~60℃ |
1~12V AC or DC |
2kN |
2mV/V (4,000×10^-6 strain) ±0.3% |
Approximately 1.9kHz |
Load receiver CA-2B |
350Ω±2Ω |
Within ±0.003%/℃ |
400Ω±50Ω |
IP67 (JIS C 0920) |
Within ±0.05%RO |
0.3mm2, 4-core shielded chloroprene 5m |
|
LUB-500KB for 5kN |
Available upon quote |
Within ±0.05%RO |
Within ±0.003%RO/℃ |
Approx. 1.5kg (excluding cable) |
150% |
-20~70℃ |
20V AC or DC |
0.03%RO or less |
-10~60℃ |
1~12V AC or DC |
5kN |
2mV/V (4,000×10^-6 strain) ±0.3% |
Approximately 1.1kHz |
Load receiver CA-2B |
350Ω±2Ω |
Within ±0.003%/℃ |
400Ω±50Ω |
IP67 (JIS C 0920) |
Within ±0.05%RO |
0.3mm2, 4-core shielded chloroprene 5m |
|
For LUB-1TB 10kN |
Available upon quote |
Within ±0.05%RO |
Within ±0.003%RO/℃ |
Approx. 1.5kg (excluding cable) |
150% |
-20~70℃ |
20V AC or DC |
0.03%RO or less |
-10~60℃ |
1~12V AC or DC |
10kN |
2mV/V (4,000×10^-6 strain) ±0.3% |
Approximately 1.2kHz |
Load receiver CA-2B |
350Ω±2Ω |
Within ±0.003%/℃ |
400Ω±50Ω |
IP67 (JIS C 0920) |
Within ±0.05%RO |
0.3mm2, 4-core shielded chloroprene 5m |
|
For LUB-2TB 20kN |
Available upon quote |
Within ±0.05%RO |
Within ±0.003%RO/℃ |
Approximately 2.8kg (excluding cable) |
150% |
-20~70℃ |
20V AC or DC |
0.03%RO or less |
-10~60℃ |
1~12V AC or DC |
20kN |
2mV/V (4,000×10^-6 strain) ±0.3% |
Approximately 1.1kHz |
Load receiver CA-2B |
350Ω±2Ω |
Within ±0.003%/℃ |
400Ω±50Ω |
IP67 (JIS C 0920) |
Within ±0.05%RO |
0.3mm2, 4-core shielded chloroprene 5m |