High precision full digital high speed response IS12 IS12-S IGA12 IGA12-SHandling Company
Yamazato Sangyo Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Weight | Communication function | Display | Insulation measures | Accuracy | Power consumption | Detection wavelength | Emissivity correction e | Response time t90 | Ambient temperature characteristics | Ambient temperature | Control panel | Resolution | Output signal | Reproducibility | Signal processing | Protection class | Storage temperature | Power supply | Location confirmation | Limit switch | Scaling | CE mark |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IS12 |
Available upon quote |
2.2kg |
RS232C or RS485 (addressable), half duplex, baud rate 2,400 ... 115,200 |
5-digit digital LED display and LED display of setting parameters |
Power supply circuit, interface, and analog output signals are isolated from each other and from the main unit. |
0.3% of measured value + 1℃ up to 1,500℃ |
Max. 7W |
0.7~1.1μm |
0.100 ... 1.000 1/1000 unit |
< 1ms, can be set up to 10s. |
Tk< 0,01% of measured value /℃ x dT (body temperature - 23℃) |
0 ... +70℃, without body cooling |
Operation using 4-way buttons, ballpoint pen tip, etc. |
0.1℃ (both via communication and display), output signal: <0.025% of temperature range |
DC4...20mA/DC0...20mA linear output (selectable), load resistance 500Ω |
0.1% of measured value + 1℃ |
Instantly digitize photocurrent |
IP65 (DIN 40 050) |
-20 ... +70℃ |
24V DC (15 ... 40VDC) or 24V AC (12 ... 30VAC) 48 ... 62Hz |
Direct view finder with diopter adjustment mechanism (standard equipment), laser pilot light (optional) |
Relay output, 2 pieces, contact rating: 30Wmax (Imax: 1A, Vmax: 60V) |
Any setting possible within the temperature range, minimum scaling range 51℃ |
Compliant with EU Directive on Electromagnetic Immunity |
|
IS12-S |
Available upon quote |
2.2kg |
RS232C or RS485 (addressable), half duplex, baud rate 2,400 ... 115,200 |
5-digit digital LED display and LED display of setting parameters |
Power supply circuit, interface, and analog output signals are isolated from each other and from the main unit. |
0.3% of measured value + 1℃ up to 1,500℃ |
Max. 7W |
0.7~1.1μm |
0.100 ... 1.000 1/1000 unit |
< 1ms, can be set up to 10s. |
Tk< 0,01% of measured value /℃ x dT (body temperature - 23℃) |
0 ... +70℃, without body cooling |
Operation using 4-way buttons, ballpoint pen tip, etc. |
0.1℃ (both via communication and display), output signal: <0.025% of temperature range |
DC4...20mA/DC0...20mA linear output (selectable), load resistance 500Ω |
0.1% of measured value + 1℃ |
Instantly digitize photocurrent |
IP65 (DIN 40 050) |
-20 ... +70℃ |
24V DC (15 ... 40VDC) or 24V AC (12 ... 30VAC) 48 ... 62Hz |
Direct view finder with diopter adjustment mechanism (standard equipment), laser pilot light (optional) |
Relay output, 2 pieces, contact rating: 30Wmax (Imax: 1A, Vmax: 60V) |
Any setting possible within the temperature range, minimum scaling range 51℃ |
Compliant with EU Directive on Electromagnetic Immunity |
|
IGA12 |
Available upon quote |
2.2kg |
RS232C or RS485 (addressable), half duplex, baud rate 2,400 ... 115,200 |
5-digit digital LED display and LED display of setting parameters |
Power supply circuit, interface, and analog output signals are isolated from each other and from the main unit. |
0.3% of measured value + 1℃ up to 1,500℃ |
Max. 7W |
1.45~1.8μm |
0.100 ... 1.000 1/1000 unit |
< 1ms, can be set up to 10s. |
Tk< 0,01% of measured value /℃ x dT (body temperature - 23℃) |
0 ... +70℃, without body cooling |
Operation using 4-way buttons, ballpoint pen tip, etc. |
0.1℃ (both via communication and display), output signal: <0.025% of temperature range |
DC4...20mA/DC0...20mA linear output (selectable), load resistance 500Ω |
0.1% of measured value + 1℃ |
Instantly digitize photocurrent |
IP65 (DIN 40 050) |
-20 ... +70℃ |
24V DC (15 ... 40VDC) or 24V AC (12 ... 30VAC) 48 ... 62Hz |
Direct view finder with diopter adjustment mechanism (standard equipment), laser pilot light (optional) |
Relay output, 2 pieces, contact rating: 30Wmax (Imax: 1A, Vmax: 60V) |
Any setting possible within the temperature range, minimum scaling range 51℃ |
Compliant with EU Directive on Electromagnetic Immunity |
|
IGA12-S |
Available upon quote |
2.2kg |
RS232C or RS485 (addressable), half duplex, baud rate 2,400 ... 115,200 |
5-digit digital LED display and LED display of setting parameters |
Power supply circuit, interface, and analog output signals are isolated from each other and from the main unit. |
0.3% of measured value + 1℃ up to 1,500℃ |
Max. 7W |
1.45~1.8μm |
0.100 ... 1.000 1/1000 unit |
< 1ms, can be set up to 10s. |
Tk< 0,01% of measured value /℃ x dT (body temperature - 23℃) |
0 ... +70℃, without body cooling |
Operation using 4-way buttons, ballpoint pen tip, etc. |
0.1℃ (both via communication and display), output signal: <0.025% of temperature range |
DC4...20mA/DC0...20mA linear output (selectable), load resistance 500Ω |
0.1% of measured value + 1℃ |
Instantly digitize photocurrent |
IP65 (DIN 40 050) |
-20 ... +70℃ |
24V DC (15 ... 40VDC) or 24V AC (12 ... 30VAC) 48 ... 62Hz |
Direct view finder with diopter adjustment mechanism (standard equipment), laser pilot light (optional) |
Relay output, 2 pieces, contact rating: 30Wmax (Imax: 1A, Vmax: 60V) |
Any setting possible within the temperature range, minimum scaling range 51℃ |
Compliant with EU Directive on Electromagnetic Immunity |