Large capacity DC electronic load QL-D series-QL-D-5K-1/B
Large capacity DC electronic load QL-D series-QL-D-10K-1
Large capacity DC electronic load QL-D series-QL-D-15K-1
Large capacity DC electronic load QL-D series-QL-D-5K-6/B
Large capacity DC electronic load QL-D series-Keisoku Giken Power Electronics

Large capacity DC electronic load QL-D series
Keisoku Giken Power Electronics

Keisoku Giken Power Electronics's Response Status

Response Rate

100.0%

Response Time

14.3hours

Relatively Fast Response


About This Product

The high-capacity DC electronic load "QL-D series" is an electronic load device that uses the oscilloscope-like UI and high-speed current control technology that have been well-received in previous electronic loads, and has improved usability and the basic performance of electronic loads. The basic specifications, performance, and concept of the conventional 34000A series have been further evolved to include a Sweep function with various load modes, an optional MPPT function, and a wide variety of functions to meet all needs. The lineup is available in 5kW increments up to 25kW, and can be expanded up to 150kW with up to 6 parallel units. It has a compact chassis with a 19-inch rack size and a height of 5U (5kW model). Compact body with large capacity. Three models are available with different rated voltages (150V, 600V, 1,000V) ranging from a minimum of 5kW to a maximum of 25kW. The 150V type supports large currents of up to 2,000A. Recommended for those who want large capacity at low cost.

■Features

・Adopts an oscilloscope-like LCD color UI from the Load Station series to improve usability. ・Electronic load with no overshoot by adopting high-speed current control technology (first in the industry to guarantee start-up current range specifications according to our research) ・There is no concept of minimum operating voltage, and linear stable operation even in the low voltage region - Equipped with sequence function. Programs can be saved/loaded using USB memory -Equipped with Sweep mode. Supports functions such as IV characteristics and overpower/overcurrent testing. Data logging is also possible and can be recorded on USB memory (CSV format) - Equipped with an optional MPPT (maximum power tracking) mode. Compatible with PV exposure tests and PCS simulations ・Equipped with elapsed time/integrated current/integrated power measurement and cut-off function using arbitrary values ・In dynamic mode, current rise/fall times can be set independently. Up to 32 steps can be set, supporting complex current simulations (overshoot current, etc.) ・LAN/USB/RS-232C standard equipment (GP-IB is optional) - Adopts CC, CV, and CP for external control mode. CC+CV and CP+CV can also be controlled externally ・Sine waves and square waves can be superimposed at up to 100kHz ・Up to 6 units can be connected in parallel (150kW), different models can be connected (same voltage models only) *Other model numbers are available.

  • Product

    Large capacity DC electronic load QL-D series

Share this product


380+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Large capacity DC electronic load QL-D series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power output Current monitor terminal Current monitor measurement accuracy Current monitor output impedance Current monitor Monitor output Voltage monitor terminal Voltage monitor measurement accuracy Voltage monitor output impedance Voltage monitor monitor output Voltage sense open alarm Overcurrent protection Overvoltage alarm Overpower protection Overheating protection Reverse connection alarm Maximum slew rate Rated current Rated voltage Rated power Parallel operation Remote sensing function Remote sensing VSENSE terminal Trigger output terminal Trigger output Output voltage Trigger output Output form Size Interface USB (HOST) Interface USB (DEVICE) Interface RS-232C Interface LAN
Large capacity DC electronic load QL-D series-Part Number-QL-D-5K-1/B

QL-D-5K-1/B

Available upon quote

DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

Load off

By current limit function (load off or current limit)

Load off

By power limit function (load off or power limit)

Load off

Load off

50A/μs

500A

150V

5kW

Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications)

Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings.

We recommend connecting with banana terminals and the included safety plug.

DI/DO DSUB 25Pin EXT contact

Pulse output

5U

USB2.0 compliant (Fullspeed)

USB2.0 compliant (Fullspeed)

D-SUB 9pin, baud rate
: Under consideration (9,600/19,200/38,400/115,200 bps), Data length: 8 bit, Stock
pbit: 1 bit,

IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible

Large capacity DC electronic load QL-D series-Part Number-QL-D-5K-1

QL-D-5K-1

Available upon quote

DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

Load off

By current limit function (load off or current limit)

Load off

By power limit function (load off or power limit)

Load off

Load off

50A/μs

500A

150V

5kW

Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications)

Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings.

We recommend connecting with banana terminals and the included safety plug.

DI/DO DSUB 25Pin EXT contact

Pulse output

5U

USB2.0 compliant (Fullspeed)

USB2.0 compliant (Fullspeed)

D-SUB 9pin, baud rate
: Under consideration (9,600/19,200/38,400/115,200 bps), Data length: 8 bit, Stock
pbit: 1 bit,

IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible

Large capacity DC electronic load QL-D series-Part Number-QL-D-10K-1

QL-D-10K-1

Available upon quote

DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

Load off

By current limit function (load off or current limit)

Load off

By power limit function (load off or power limit)

Load off

Load off

50A/μs

1,000A

150V

10kW

Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications)

Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings.

We recommend connecting with banana terminals and the included safety plug.

DI/DO DSUB 25Pin EXT contact

Pulse output

11U

USB2.0 compliant (Fullspeed)

USB2.0 compliant (Fullspeed)

D-SUB 9pin, baud rate
: Under consideration (9,600/19,200/38,400/115,200 bps), Data length: 8 bit, Stock
pbit: 1 bit,

IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible

Large capacity DC electronic load QL-D series-Part Number-QL-D-15K-1

QL-D-15K-1

Available upon quote

DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

Load off

By current limit function (load off or current limit)

Load off

By power limit function (load off or power limit)

Load off

Load off

50A/μs

1,500A

150V

15kW

Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications)

Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings.

We recommend connecting with banana terminals and the included safety plug.

DI/DO DSUB 25Pin EXT contact

Pulse output

15U

USB2.0 compliant (Fullspeed)

USB2.0 compliant (Fullspeed)

D-SUB 9pin, baud rate
: Under consideration (9,600/19,200/38,400/115,200 bps), Data length: 8 bit, Stock
pbit: 1 bit,

IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible

Large capacity DC electronic load QL-D series-Part Number-QL-D-5K-6/B

QL-D-5K-6/B

Available upon quote

DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

Load off

By current limit function (load off or current limit)

Load off

By power limit function (load off or power limit)

Load off

Load off

50A/μs

2,000A

150V

20kW

Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications)

Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings.

We recommend connecting with banana terminals and the included safety plug.

DI/DO DSUB 25Pin EXT contact

Pulse output

19U

USB2.0 compliant (Fullspeed)

USB2.0 compliant (Fullspeed)

D-SUB 9pin, baud rate
: Under consideration (9,600/19,200/38,400/115,200 bps), Data length: 8 bit, Stock
pbit: 1 bit,

IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible

Large capacity DC electronic load QL-D series-Part Number-QL-D-5K-6

QL-D-5K-6

Available upon quote

DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

Load off

By current limit function (load off or current limit)

Load off

By power limit function (load off or power limit)

Load off

Load off

20A/μs

350A

600V

5kW

Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications)

Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings.

We recommend connecting with banana terminals and the included safety plug.

DI/DO DSUB 25Pin EXT contact

Pulse output

5U

USB2.0 compliant (Fullspeed)

USB2.0 compliant (Fullspeed)

D-SUB 9pin, baud rate
: Under consideration (9,600/19,200/38,400/115,200 bps), Data length: 8 bit, Stock
pbit: 1 bit,

IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible

Large capacity DC electronic load QL-D series-Part Number-QL-D-10K-6

QL-D-10K-6

Available upon quote

DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

Load off

By current limit function (load off or current limit)

Load off

By power limit function (load off or power limit)

Load off

Load off

20A/μs

350A

600V

5kW

Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications)

Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings.

We recommend connecting with banana terminals and the included safety plug.

DI/DO DSUB 25Pin EXT contact

Pulse output

5U

USB2.0 compliant (Fullspeed)

USB2.0 compliant (Fullspeed)

D-SUB 9pin, baud rate
: Under consideration (9,600/19,200/38,400/115,200 bps), Data length: 8 bit, Stock
pbit: 1 bit,

IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible

Large capacity DC electronic load QL-D series-Part Number-QL-D-15K-6

QL-D-15K-6

Available upon quote

DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

Load off

By current limit function (load off or current limit)

Load off

By power limit function (load off or power limit)

Load off

Load off

20A/μs

700A

600V

10kW

Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications)

Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings.

We recommend connecting with banana terminals and the included safety plug.

DI/DO DSUB 25Pin EXT contact

Pulse output

11U

USB2.0 compliant (Fullspeed)

USB2.0 compliant (Fullspeed)

D-SUB 9pin, baud rate
: Under consideration (9,600/19,200/38,400/115,200 bps), Data length: 8 bit, Stock
pbit: 1 bit,

IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible

Large capacity DC electronic load QL-D series-Part Number-QL-D-20K-6

QL-D-20K-6

Available upon quote

DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

Load off

By current limit function (load off or current limit)

Load off

By power limit function (load off or power limit)

Load off

Load off

20A/μs

1,050A

600V

15kW

Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications)

Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings.

We recommend connecting with banana terminals and the included safety plug.

DI/DO DSUB 25Pin EXT contact

Pulse output

15U

USB2.0 compliant (Fullspeed)

USB2.0 compliant (Fullspeed)

D-SUB 9pin, baud rate
: Under consideration (9,600/19,200/38,400/115,200 bps), Data length: 8 bit, Stock
pbit: 1 bit,

IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible

Large capacity DC electronic load QL-D series-Part Number-QL-D-25K-6

QL-D-25K-6

Available upon quote

DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

BNC

±{1% of Conv.Volt. +1% of F.S.}

50Ω

5V full scale

Load off

By current limit function (load off or current limit)

Load off

By power limit function (load off or power limit)

Load off

Load off

20A/μs

1,400A

600V

20kW

Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications)

Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings.

We recommend connecting with banana terminals and the included safety plug.

DI/DO DSUB 25Pin EXT contact

Pulse output

19U

USB2.0 compliant (Fullspeed)

USB2.0 compliant (Fullspeed)

D-SUB 9pin, baud rate
: Under consideration (9,600/19,200/38,400/115,200 bps), Data length: 8 bit, Stock
pbit: 1 bit,

IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Electronic Loads Products

Other products of Keisoku Giken Power Electronics

Reviews shown here are reviews of companies.


View more products of Keisoku Giken Power Electronics