All Categories
History
Response Rate
100.0%
Response Time
14.3hours
Relatively Fast Response
Product
Large capacity DC electronic load QL-D seriesHandling Company
Keisoku Giken Power ElectronicsCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power output | Current monitor terminal | Current monitor measurement accuracy | Current monitor output impedance | Current monitor Monitor output | Voltage monitor terminal | Voltage monitor measurement accuracy | Voltage monitor output impedance | Voltage monitor monitor output | Voltage sense open alarm | Overcurrent protection | Overvoltage alarm | Overpower protection | Overheating protection | Reverse connection alarm | Maximum slew rate | Rated current | Rated voltage | Rated power | Parallel operation | Remote sensing function | Remote sensing VSENSE terminal | Trigger output terminal | Trigger output Output voltage | Trigger output Output form | Size | Interface USB (HOST) | Interface USB (DEVICE) | Interface RS-232C | Interface LAN |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
QL-D-5K-1/B |
Available upon quote |
DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
Load off |
By current limit function (load off or current limit) |
Load off |
By power limit function (load off or power limit) |
Load off |
Load off |
50A/μs |
500A |
150V |
5kW |
Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications) |
Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings. |
We recommend connecting with banana terminals and the included safety plug. |
DI/DO DSUB 25Pin EXT contact |
|
Pulse output |
5U |
USB2.0 compliant (Fullspeed) |
USB2.0 compliant (Fullspeed) |
D-SUB 9pin, baud rate |
IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible |
|
QL-D-5K-1 |
Available upon quote |
DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
Load off |
By current limit function (load off or current limit) |
Load off |
By power limit function (load off or power limit) |
Load off |
Load off |
50A/μs |
500A |
150V |
5kW |
Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications) |
Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings. |
We recommend connecting with banana terminals and the included safety plug. |
DI/DO DSUB 25Pin EXT contact |
|
Pulse output |
5U |
USB2.0 compliant (Fullspeed) |
USB2.0 compliant (Fullspeed) |
D-SUB 9pin, baud rate |
IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible |
|
QL-D-10K-1 |
Available upon quote |
DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
Load off |
By current limit function (load off or current limit) |
Load off |
By power limit function (load off or power limit) |
Load off |
Load off |
50A/μs |
1,000A |
150V |
10kW |
Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications) |
Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings. |
We recommend connecting with banana terminals and the included safety plug. |
DI/DO DSUB 25Pin EXT contact |
|
Pulse output |
11U |
USB2.0 compliant (Fullspeed) |
USB2.0 compliant (Fullspeed) |
D-SUB 9pin, baud rate |
IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible |
|
QL-D-15K-1 |
Available upon quote |
DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
Load off |
By current limit function (load off or current limit) |
Load off |
By power limit function (load off or power limit) |
Load off |
Load off |
50A/μs |
1,500A |
150V |
15kW |
Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications) |
Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings. |
We recommend connecting with banana terminals and the included safety plug. |
DI/DO DSUB 25Pin EXT contact |
|
Pulse output |
15U |
USB2.0 compliant (Fullspeed) |
USB2.0 compliant (Fullspeed) |
D-SUB 9pin, baud rate |
IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible |
|
QL-D-5K-6/B |
Available upon quote |
DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
Load off |
By current limit function (load off or current limit) |
Load off |
By power limit function (load off or power limit) |
Load off |
Load off |
50A/μs |
2,000A |
150V |
20kW |
Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications) |
Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings. |
We recommend connecting with banana terminals and the included safety plug. |
DI/DO DSUB 25Pin EXT contact |
|
Pulse output |
19U |
USB2.0 compliant (Fullspeed) |
USB2.0 compliant (Fullspeed) |
D-SUB 9pin, baud rate |
IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible |
|
QL-D-5K-6 |
Available upon quote |
DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
Load off |
By current limit function (load off or current limit) |
Load off |
By power limit function (load off or power limit) |
Load off |
Load off |
20A/μs |
350A |
600V |
5kW |
Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications) |
Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings. |
We recommend connecting with banana terminals and the included safety plug. |
DI/DO DSUB 25Pin EXT contact |
|
Pulse output |
5U |
USB2.0 compliant (Fullspeed) |
USB2.0 compliant (Fullspeed) |
D-SUB 9pin, baud rate |
IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible |
|
QL-D-10K-6 |
Available upon quote |
DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
Load off |
By current limit function (load off or current limit) |
Load off |
By power limit function (load off or power limit) |
Load off |
Load off |
20A/μs |
350A |
600V |
5kW |
Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications) |
Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings. |
We recommend connecting with banana terminals and the included safety plug. |
DI/DO DSUB 25Pin EXT contact |
|
Pulse output |
5U |
USB2.0 compliant (Fullspeed) |
USB2.0 compliant (Fullspeed) |
D-SUB 9pin, baud rate |
IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible |
|
QL-D-15K-6 |
Available upon quote |
DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
Load off |
By current limit function (load off or current limit) |
Load off |
By power limit function (load off or power limit) |
Load off |
Load off |
20A/μs |
700A |
600V |
10kW |
Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications) |
Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings. |
We recommend connecting with banana terminals and the included safety plug. |
DI/DO DSUB 25Pin EXT contact |
|
Pulse output |
11U |
USB2.0 compliant (Fullspeed) |
USB2.0 compliant (Fullspeed) |
D-SUB 9pin, baud rate |
IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible |
|
QL-D-20K-6 |
Available upon quote |
DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
Load off |
By current limit function (load off or current limit) |
Load off |
By power limit function (load off or power limit) |
Load off |
Load off |
20A/μs |
1,050A |
600V |
15kW |
Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications) |
Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings. |
We recommend connecting with banana terminals and the included safety plug. |
DI/DO DSUB 25Pin EXT contact |
|
Pulse output |
15U |
USB2.0 compliant (Fullspeed) |
USB2.0 compliant (Fullspeed) |
D-SUB 9pin, baud rate |
IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible |
|
QL-D-25K-6 |
Available upon quote |
DI/DO DSUB 25Pin +5V output contact, supply capacity 100mA |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
BNC |
±{1% of Conv.Volt. +1% of F.S.} |
50Ω |
5V full scale |
Load off |
By current limit function (load off or current limit) |
Load off |
By power limit function (load off or power limit) |
Load off |
Load off |
20A/μs |
1,400A |
600V |
20kW |
Up to 6 units possible (parallel operation with different capacities is possible if they have the same voltage specifications) |
Voltage detection can be selected from INT (load terminal) or EXT (EXT IN terminal) in the main unit settings. |
We recommend connecting with banana terminals and the included safety plug. |
DI/DO DSUB 25Pin EXT contact |
|
Pulse output |
19U |
USB2.0 compliant (Fullspeed) |
USB2.0 compliant (Fullspeed) |
D-SUB 9pin, baud rate |
IEEE 802,3 100Base-Tx/10Base-T Ethernet IPv4, RJ-45 connector, TCP/IP, Keep Alive compatible |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.