Product
Unit type DC-DC converter SDX series SDX200Handling Company
Power Science Tokai Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Environmental conditions Cooling method | Environmental conditions Operating temperature/humidity | Environmental conditions Storage temperature/humidity | External dimensions mm (mass) | Impact | Input voltage | Insulation voltage Output FG | Insulation voltage input car FG | Insulation voltage input car output | Maximum rated current | Output voltage variable range | Protection conditions Overcurrent protection | Protection conditions Overvoltage protection | Rated output voltage | Ripple mVp-p | Safety standards | Series operation | Static input variation | Static load fluctuation | Vibration |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SDX2002412 |
Available upon quote | Natural air cooling |
-20℃~+60℃ 20~90%RH (no condensation) Standard installation |
-40℃~+85℃ 20~90%RH (no haze) | W82×H88.5×D94.5 not including terminal block (650g) | 196m/s (20G) 3 times each in X, Y, and Z directions | 24V (18V~36V) | AC500V for 1 minute | DC1,500V for 1 minute or AC1,000V for 1 minute | DC1,500V for 1 minute or AC1,000V for 1 minute | 16.7A | 7.5V~13.2V | Operates at 105% min of rated current, automatic recovery | Output cutoff type, recovers by reapplying input | 12V | 48mV~180mV | UL60950, C-UL. EN60950 compliant | Possible | 24mV~95mV max | 24mV~190mV max | 10~55Hz when not operating for 1 hour each in X, Y, and Z directions | |
SDX2002424 |
Available upon quote | Natural air cooling |
-20℃~+60℃ 20~90%RH (no condensation) Standard installation |
-40℃~+85℃ 20~90%RH (no haze) | W82×H88.5×D94.5 not including terminal block (650g) | 196m/s (20G) 3 times each in X, Y, and Z directions | 24V (18V~36V) | AC500V for 1 minute | DC1,500V for 1 minute or AC1,000V for 1 minute | DC1,500V for 1 minute or AC1,000V for 1 minute | 8.4A | 14.4V~26.4V | Operates at 105% min of rated current, automatic recovery | Output cutoff type, recovers by reapplying input | 24V | 48mV~180mV | UL60950, C-UL. EN60950 compliant | Possible | 24mV~95mV max | 24mV~190mV max | 10~55Hz when not operating for 1 hour each in X, Y, and Z directions | |
SDX2004812 |
Available upon quote | Natural air cooling |
-20℃~+60℃ 20~90%RH (no condensation) Standard installation |
-40℃~+85℃ 20~90%RH (no haze) | W82×H88.5×D94.5 not including terminal block (650g) | 196m/s (20G) 3 times each in X, Y, and Z directions | 48V (36V~76V) | AC500V for 1 minute | DC1,500V for 1 minute or AC1,000V for 1 minute | DC1,500V for 1 minute or AC1,000V for 1 minute | 16.7A | 7.5V~13.2V | Operates at 105% min of rated current, automatic recovery | Output cutoff type, recovers by reapplying input | 12V | 48mV~180mV | UL60950, C-UL. EN60950 compliant | Possible | 24mV~95mV max | 24mV~190mV max | 10~55Hz when not operating for 1 hour each in X, Y, and Z directions | |
SDX2004824 |
Available upon quote | Natural air cooling |
-20℃~+60℃ 20~90%RH (no condensation) Standard installation |
-40℃~+85℃ 20~90%RH (no haze) | W82×H88.5×D94.5 not including terminal block (650g) | 196m/s (20G) 3 times each in X, Y, and Z directions | 48V (36V~76V) | AC500V for 1 minute | DC1,500V for 1 minute or AC1,000V for 1 minute | DC1,500V for 1 minute or AC1,000V for 1 minute | 8.4A | 14.4V~26.4V | Operates at 105% min of rated current, automatic recovery | Output cutoff type, recovers by reapplying input | 24V | 48mV~180mV | UL60950, C-UL. EN60950 compliant | Possible | 24mV~95mV max | 24mV~190mV max | 10~55Hz when not operating for 1 hour each in X, Y, and Z directions |
Click on the part number for more information about each product