Product
Thyristor controlled DC stabilized power supply DS,DS3 Single phase input 1φ100V systemHandling Company
Power Science Tokai Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Depth D (mm) | Dielectric strength | Efficiency | Height H (mm) | Input | Input voltage range | Insulation resistance | Load conditions | Maximum capacity (W) | Operating temperature | Output overvoltage protection | Output voltage accuracy | Overload protection | Paint color | Rated current (A) | Rated voltage (variable range) (V) | Relative humidity | Response time | Ripple voltage | Voltage variable range | Weight (kg) | Width W (mm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DS-25-1Z1 |
Available upon quote | 400 | AC1,500V for 1 minute | Approximately 70% or more | 199 |
1φ or 3φ 48~62Hz 100V, 200V, 440V |
Rated voltage ±10% | DC500V megger 10MΩ or more | 0~100% (current) | 375 | -10~40℃ | Input breaker trips at approximately 130% of rated voltage | Rated voltage ±1% | Droops at approximately 110% of rated current | Munsell 5Y7/1 | Twenty five | 12V (2-15V) | 30~85%RH | Within 0.3 seconds (at 50% or more load) | 2% (rms) | 20~150% | 35 | 420 | |
DS-38-1Z1 |
Available upon quote | 500 | AC1,500V for 1 minute | Approximately 70% or more | 249 |
1φ or 3φ 48~62Hz 100V, 200V, 440V |
Rated voltage ±10% | DC500V megger 10MΩ or more | 0~100% (current) | 570 | -10~40℃ | Input breaker trips at approximately 130% of rated voltage | Rated voltage ±1% | Droops at approximately 110% of rated current | Munsell 5Y7/1 | 38 | 12V (2-15V) | 30~85%RH | Within 0.3 seconds (at 50% or more load) | 2% (rms) | 20~150% | 40 | 420 | |
DS-50-1Z1 |
Available upon quote | 500 | AC1,500V for 1 minute | Approximately 70% or more | 349 |
1φ or 3φ 48~62Hz 100V, 200V, 440V |
Rated voltage ±10% | DC500V megger 10MΩ or more | 0~100% (current) | 750 | -10~40℃ | Input breaker trips at approximately 130% of rated voltage | Rated voltage ±1% | Droops at approximately 110% of rated current | Munsell 5Y7/1 | 50 | 12V (2-15V) | 30~85%RH | Within 0.3 seconds (at 50% or more load) | 2% (rms) | 20~150% | 55 | 420 | |
DS-75-1Z1 |
Available upon quote | 450 | AC1,500V for 1 minute | Approximately 70% or more | 670 |
1φ or 3φ 48~62Hz 100V, 200V, 440V |
Rated voltage ±10% | DC500V megger 10MΩ or more | 0~100% (current) | 1.1K | -10~40℃ | Input breaker trips at approximately 130% of rated voltage | Rated voltage ±1% | Droops at approximately 110% of rated current | Munsell 5Y7/1 | 75 | 12V (2-15V) | 30~85%RH | Within 0.3 seconds (at 50% or more load) | 2% (rms) | 20~150% | 90 | 350 | |
DS-100-1Z1 |
Available upon quote | 550 | AC1,500V for 1 minute | Approximately 70% or more | 770 |
1φ or 3φ 48~62Hz 100V, 200V, 440V |
Rated voltage ±10% | DC500V megger 10MΩ or more | 0~100% (current) | 1.5K | -10~40℃ | Input breaker trips at approximately 130% of rated voltage | Rated voltage ±1% | Droops at approximately 110% of rated current | Munsell 5Y7/1 | 100 | 12V (2-15V) | 30~85%RH | Within 0.3 seconds (at 50% or more load) | 2% (rms) | 20~150% | 110 | 400 | |
DS-150-1Z1 |
Available upon quote | 550 | AC1,500V for 1 minute | Approximately 70% or more | 770 |
1φ or 3φ 48~62Hz 100V, 200V, 440V |
Rated voltage ±10% | DC500V megger 10MΩ or more | 0~100% (current) | 2.2K | -10~40℃ | Input breaker trips at approximately 130% of rated voltage | Rated voltage ±1% | Droops at approximately 110% of rated current | Munsell 5Y7/1 | 150 | 12V (2-15V) | 30~85%RH | Within 0.3 seconds (at 50% or more load) | 2% (rms) | 20~150% | 130 | 400 | |
DS-200-1Z1 |
Available upon quote | 550 | AC1,500V for 1 minute | Approximately 70% or more | 770 |
1φ or 3φ 48~62Hz 100V, 200V, 440V |
Rated voltage ±10% | DC500V megger 10MΩ or more | 0~100% (current) | 3.0K | -10~40℃ | Input breaker trips at approximately 130% of rated voltage | Rated voltage ±1% | Droops at approximately 110% of rated current | Munsell 5Y7/1 | 200 | 12V (2-15V) | 30~85%RH | Within 0.3 seconds (at 50% or more load) | 2% (rms) | 20~150% | 140 | 400 | |
DS-10-3Z1 |
Available upon quote | 400 | AC1,500V for 1 minute | Approximately 70% or more | 199 |
1φ or 3φ 48~62Hz 100V, 200V, 440V |
Rated voltage ±10% | DC500V megger 10MΩ or more | 0~100% (current) | 375 | -10~40℃ | Input breaker trips at approximately 130% of rated voltage | Rated voltage ±1% | Droops at approximately 110% of rated current | Munsell 5Y7/1 | 10 | 25V (5-30V) | 30~85%RH | Within 0.3 seconds (at 50% or more load) | 2% (rms) | 20~150% | Twenty five | 420 | |
DS-15-3Z1 |
Available upon quote | 400 | AC1,500V for 1 minute | Approximately 70% or more | 199 |
1φ or 3φ 48~62Hz 100V, 200V, 440V |
Rated voltage ±10% | DC500V megger 10MΩ or more | 0~100% (current) | 450 | -10~40℃ | Input breaker trips at approximately 130% of rated voltage | Rated voltage ±1% | Droops at approximately 110% of rated current | Munsell 5Y7/1 | 15 | 25V (5-30V) | 30~85%RH | Within 0.3 seconds (at 50% or more load) | 2% (rms) | 20~150% | 35 | 420 | |
DS-25-3Z1 |
Available upon quote | 500 | AC1,500V for 1 minute | Approximately 70% or more | 249 |
1φ or 3φ 48~62Hz 100V, 200V, 440V |
Rated voltage ±10% | DC500V megger 10MΩ or more | 0~100% (current) | 750 | -10~40℃ | Input breaker trips at approximately 130% of rated voltage | Rated voltage ±1% | Droops at approximately 110% of rated current | Munsell 5Y7/1 | Twenty five | 25V (5-30V) | 30~85%RH | Within 0.3 seconds (at 50% or more load) | 2% (rms) | 20~150% | 38 | 420 |
Click on the part number for more information about each product