Thyristor controlled DC stabilized power supply DS,DS3 Single phase input 1φ100V systemHandling Company
Power Science Tokai Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Height H (mm) | Voltage variable range | Weight (kg) | Overload protection | Load conditions | Dielectric strength | Insulation resistance | Relative humidity | Maximum capacity (W) | Response time | Width W (mm) | Rated current (A) | Rated voltage (variable range) (V) | Depth D (mm) | Paint color | Efficiency | Output voltage accuracy | Output overvoltage protection | Input voltage range | Input | Operating temperature | Ripple voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DS-25-1Z1 |
Available upon quote |
199 |
20~150% |
35 |
Droops at approximately 110% of rated current |
0~100% (current) |
AC1,500V for 1 minute |
DC500V megger 10MΩ or more |
30~85%RH |
375 |
Within 0.3 seconds (at 50% or more load) |
420 |
Twenty five |
12V (2-15V) |
400 |
Munsell 5Y7/1 |
Approximately 70% or more |
Rated voltage ±1% |
Input breaker trips at approximately 130% of rated voltage |
Rated voltage ±10% |
1φ or 3φ 48~62Hz |
-10~40℃ |
2% (rms) |
|
DS-38-1Z1 |
Available upon quote |
249 |
20~150% |
40 |
Droops at approximately 110% of rated current |
0~100% (current) |
AC1,500V for 1 minute |
DC500V megger 10MΩ or more |
30~85%RH |
570 |
Within 0.3 seconds (at 50% or more load) |
420 |
38 |
12V (2-15V) |
500 |
Munsell 5Y7/1 |
Approximately 70% or more |
Rated voltage ±1% |
Input breaker trips at approximately 130% of rated voltage |
Rated voltage ±10% |
1φ or 3φ 48~62Hz |
-10~40℃ |
2% (rms) |
|
DS-50-1Z1 |
Available upon quote |
349 |
20~150% |
55 |
Droops at approximately 110% of rated current |
0~100% (current) |
AC1,500V for 1 minute |
DC500V megger 10MΩ or more |
30~85%RH |
750 |
Within 0.3 seconds (at 50% or more load) |
420 |
50 |
12V (2-15V) |
500 |
Munsell 5Y7/1 |
Approximately 70% or more |
Rated voltage ±1% |
Input breaker trips at approximately 130% of rated voltage |
Rated voltage ±10% |
1φ or 3φ 48~62Hz |
-10~40℃ |
2% (rms) |
|
DS-75-1Z1 |
Available upon quote |
670 |
20~150% |
90 |
Droops at approximately 110% of rated current |
0~100% (current) |
AC1,500V for 1 minute |
DC500V megger 10MΩ or more |
30~85%RH |
1.1K |
Within 0.3 seconds (at 50% or more load) |
350 |
75 |
12V (2-15V) |
450 |
Munsell 5Y7/1 |
Approximately 70% or more |
Rated voltage ±1% |
Input breaker trips at approximately 130% of rated voltage |
Rated voltage ±10% |
1φ or 3φ 48~62Hz |
-10~40℃ |
2% (rms) |
|
DS-100-1Z1 |
Available upon quote |
770 |
20~150% |
110 |
Droops at approximately 110% of rated current |
0~100% (current) |
AC1,500V for 1 minute |
DC500V megger 10MΩ or more |
30~85%RH |
1.5K |
Within 0.3 seconds (at 50% or more load) |
400 |
100 |
12V (2-15V) |
550 |
Munsell 5Y7/1 |
Approximately 70% or more |
Rated voltage ±1% |
Input breaker trips at approximately 130% of rated voltage |
Rated voltage ±10% |
1φ or 3φ 48~62Hz |
-10~40℃ |
2% (rms) |
|
DS-150-1Z1 |
Available upon quote |
770 |
20~150% |
130 |
Droops at approximately 110% of rated current |
0~100% (current) |
AC1,500V for 1 minute |
DC500V megger 10MΩ or more |
30~85%RH |
2.2K |
Within 0.3 seconds (at 50% or more load) |
400 |
150 |
12V (2-15V) |
550 |
Munsell 5Y7/1 |
Approximately 70% or more |
Rated voltage ±1% |
Input breaker trips at approximately 130% of rated voltage |
Rated voltage ±10% |
1φ or 3φ 48~62Hz |
-10~40℃ |
2% (rms) |
|
DS-200-1Z1 |
Available upon quote |
770 |
20~150% |
140 |
Droops at approximately 110% of rated current |
0~100% (current) |
AC1,500V for 1 minute |
DC500V megger 10MΩ or more |
30~85%RH |
3.0K |
Within 0.3 seconds (at 50% or more load) |
400 |
200 |
12V (2-15V) |
550 |
Munsell 5Y7/1 |
Approximately 70% or more |
Rated voltage ±1% |
Input breaker trips at approximately 130% of rated voltage |
Rated voltage ±10% |
1φ or 3φ 48~62Hz |
-10~40℃ |
2% (rms) |
|
DS-10-3Z1 |
Available upon quote |
199 |
20~150% |
Twenty five |
Droops at approximately 110% of rated current |
0~100% (current) |
AC1,500V for 1 minute |
DC500V megger 10MΩ or more |
30~85%RH |
375 |
Within 0.3 seconds (at 50% or more load) |
420 |
10 |
25V (5-30V) |
400 |
Munsell 5Y7/1 |
Approximately 70% or more |
Rated voltage ±1% |
Input breaker trips at approximately 130% of rated voltage |
Rated voltage ±10% |
1φ or 3φ 48~62Hz |
-10~40℃ |
2% (rms) |
|
DS-15-3Z1 |
Available upon quote |
199 |
20~150% |
35 |
Droops at approximately 110% of rated current |
0~100% (current) |
AC1,500V for 1 minute |
DC500V megger 10MΩ or more |
30~85%RH |
450 |
Within 0.3 seconds (at 50% or more load) |
420 |
15 |
25V (5-30V) |
400 |
Munsell 5Y7/1 |
Approximately 70% or more |
Rated voltage ±1% |
Input breaker trips at approximately 130% of rated voltage |
Rated voltage ±10% |
1φ or 3φ 48~62Hz |
-10~40℃ |
2% (rms) |
|
DS-25-3Z1 |
Available upon quote |
249 |
20~150% |
38 |
Droops at approximately 110% of rated current |
0~100% (current) |
AC1,500V for 1 minute |
DC500V megger 10MΩ or more |
30~85%RH |
750 |
Within 0.3 seconds (at 50% or more load) |
420 |
Twenty five |
25V (5-30V) |
500 |
Munsell 5Y7/1 |
Approximately 70% or more |
Rated voltage ±1% |
Input breaker trips at approximately 130% of rated voltage |
Rated voltage ±10% |
1φ or 3φ 48~62Hz |
-10~40℃ |
2% (rms) |
Click on the part number for more information about each product