Illuminometer T-10A/T-10MA/T-10WSA/T-10WLA-T-10A
Illuminometer T-10A/T-10MA/T-10WSA/T-10WLA-Konica Minolta Japan Co., Ltd.

Illuminometer T-10A/T-10MA/T-10WSA/T-10WLA
Konica Minolta Japan Co., Ltd.

🏗️ Architecture & Construction Use 🚗 Automotive & Transport Use 💻 Electronics & Electrical Use

About This Product

■Summary ・T-10A/T-10MA is a high-precision illumination meter that complies with JIS AA class and DIN Class B. ・Next-generation lighting that supports PWM light can also be accurately measured, making it easy to build an equiluminance measurement system that can be incorporated into multi-point measurement and testing equipment. ■Main uses ・Research and inspection of lighting equipment manufacturers ・Government testing agency ・Maintenance management of factories, offices, hospitals, etc. ・Illuminance management of security lights and street lights ・Architecture-related light source check ・Illuminance management at LED plant factories ・As a sensor for total luminous flux/light distribution characteristic device, etc. ■Compatible with PWM light. Measurement of next-generation light sources is also possible. PWM is an abbreviation for Pulse Width Modulation, which is a method of controlling signal strength by adjusting the ratio of ON and OFF periods of a pulse signal. A pulse signal is a signal that repeats an ON state and an OFF state, and the ratio of the ON period to one cycle is called the duty ratio. PWM dimming is a method of adjusting brightness by adjusting the duty ratio (lighting time) of pulsed light. The longer the lighting time, the brighter the light; the shorter the lighting time, the darker the light. ■Compliant with JIS AA class and DIN Class B T-10A and T-10MA comply with JIS C 1609-1:2006 General Total AA Class Illuminance Meter and DIN 5032 Part 7 1985 Edition Class-B. A reliable illumination meter that pursues high accuracy and reliability. *This device has received type approval under the Measurement Act for the main body and light receiving section. Type approval has not been obtained for cases where the main body and light receiving section are used separately (cable extension/multi-point measurement). The model approval number is applied to combinations with the same matching number written on the nameplate of both the main unit and the receiver. ■Multi-point measurement possible You can easily measure the illuminance distribution of architectural lighting, street lights, projectors, etc. with one device. ■Remote measurement possible Since the light receiving section can be removed from the main body and connected using a commercially available LAN cable, it can be easily integrated into the customer's inspection system.

  • Product

    Illuminometer T-10A/T-10MA/T-10WSA/T-10WLA
  • Usage Scenarios

    Architecture & Construction Use / Automotive & Transport Use / Electronics & Electrical Use

Share this product


500+ people viewing

Last viewed: 8 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

4 Models of Illuminometer T-10A/T-10MA/T-10WSA/T-10WLA

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Analog signal output Battery life Class of illumination meter Cord length Correction function Digital signal input/output Display Humidity characteristics Linearity Mass (without battery) Measurement function Measuring range Oblique incident light characteristics Operating temperature and humidity range Photodetector Power supply Size/mass Spectral responsivity Standard accessories Storage temperature and humidity range Temperature characteristics Type
Illuminometer T-10A/T-10MA/T-10WSA/T-10WLA-Part Number-T-10A

T-10A

Available upon quote 1mV/1digit, maximum saturation voltage 3V, output impedance 10kΩ, 90% response time 28mS 72 hours or more (in continuous measurement when using alkaline batteries) Conforms to JIS C 1609-1:2006 general type AA class illuminance meter Conforms to DIN 5032 Part7 1985 edition Class-B - Setting by correction coefficient (C.C.F): Measured value x 0.500~2.000 USB LCD number of valid digits: 3 digits (some 4 digits) With backlight illumination (automatic illumination) ±3% of indicated value (according to our test conditions) ±2% of indicated value ±1digit 200g NORM: Illuminance (lx) ⊿: Illuminance difference (lx) ・Illuminance ratio (%) Σ: Integrated illuminance (lx・h) ・Integrated time (h) Time average illuminance (lx) Auto range (manual 5 range when analog output) 3% or less -10~40℃ Relative humidity 85% or less (at 35℃) /No condensation Silicon photocell 2 AA batteries/dedicated AC adapter (sold separately) 69 (width) x 174 (height) x 35 (depth) Deviation from standard spectral luminous efficiency (f1’) 6% or less Battery case, cap, strap -20~55℃ Relative humidity 85% or less (at 35℃) /No condensation ±3% of indicated value (according to our test conditions) Standard light receiving area
Illuminometer T-10A/T-10MA/T-10WSA/T-10WLA-Part Number-T-10MA

T-10MA

Available upon quote 1mV/1digit, maximum saturation voltage 3V, output impedance 10kΩ, 90% response time 28mS 72 hours or more (in continuous measurement when using alkaline batteries) Conforms to JIS C 1609-1:2006 general type AA class illuminance meter Conforms to DIN 5032 Part7 1985 edition Class-B 1m Setting by correction coefficient (C.C.F): Measured value x 0.500~2.000 USB LCD number of valid digits: 3 digits (some 4 digits) With backlight illumination (automatic illumination) ±3% of indicated value (according to our test conditions) ±2% of indicated value ±1digit 205g NORM: Illuminance (lx) ⊿: Illuminance difference (lx) ・Illuminance ratio (%) Σ: Integrated illuminance (lx・h) ・Integrated time (h) Time average illuminance (lx) Auto range (manual 5 range when analog output) 3% or less -10~40℃ Relative humidity 85% or less (at 35℃) /No condensation Silicon photocell 2 AA batteries/dedicated AC adapter (sold separately) 69 (width) x 174 (height) x 35 (depth) Deviation from standard spectral luminous efficiency (f1’) 6% or less Battery case, cap, strap -20~55℃ Relative humidity 85% or less (at 35℃) /No condensation ±3% of indicated value (according to our test conditions) Mini light receiver
Illuminometer T-10A/T-10MA/T-10WSA/T-10WLA-Part Number-T-10WSA

T-10WSA

Available upon quote 1mV/1digit, maximum saturation voltage 3V, output impedance 10kΩ, 90% response time 28mS 72 hours or more (in continuous measurement when using alkaline batteries) Compliant with JISC 1609-1:2006 special type illuminance measuring device 5m Setting by correction coefficient (C.C.F): Measured value x 0.500~2.000 USB LCD number of valid digits: 3 digits (some 4 digits) With backlight illumination (automatic illumination) ±3% of indicated value (according to our test conditions) ±2% of indicated value ±1digit 260g (light receiving part only 120g) NORM: Illuminance (lx) ⊿: Illuminance difference (lx) ・Illuminance ratio (%) Σ: Integrated illuminance (lx・h) ・Integrated time (h) Time average illuminance (lx) Auto range (manual 5 range when analog output) 10% or less 5~40℃ Relative humidity 85% or less (at 35℃) /No condensation Silicon photocell 2 AA batteries/dedicated AC adapter (sold separately) 69 (width) x 174 (height) x 35 (depth) Deviation from standard spectral luminous efficiency (f1’) 6% or less Battery, case, mini cap, strap 0~55℃ Relative humidity 85% or less (at 35℃) /No condensation ±3% of indicated value (according to our test conditions) Waterproof mini receiver
Illuminometer T-10A/T-10MA/T-10WSA/T-10WLA-Part Number-T-10WLA

T-10WLA

Available upon quote 1mV/1digit, maximum saturation voltage 3V, output impedance 10kΩ, 90% response time 28mS 72 hours or more (in continuous measurement when using alkaline batteries) Compliant with JISC 1609-1:2006 special type illuminance measuring device 10m Setting by correction coefficient (C.C.F): Measured value x 0.500~2.000 USB LCD number of valid digits: 3 digits (some 4 digits) With backlight illumination (automatic illumination) ±3% of indicated value (according to our test conditions) ±2% of indicated value ±1digit 340g (receiver only 200g) NORM: Illuminance (lx) ⊿: Illuminance difference (lx) ・Illuminance ratio (%) Σ: Integrated illuminance (lx・h) ・Integrated time (h) Time average illuminance (lx) Auto range (manual 5 range when analog output) 10% or less 5~40℃ Relative humidity 85% or less (at 35℃) /No condensation Silicon photocell 2 AA batteries/dedicated AC adapter (sold separately) 69 (width) x 174 (height) x 35 (depth) Deviation from standard spectral luminous efficiency (f1’) 6% or less Battery, case, mini cap, strap 0~55℃ Relative humidity 85% or less (at 35℃) /No condensation ±3% of indicated value (according to our test conditions) Waterproof mini receiver

Click on the part number for more information about each product