■Summary -Uses easy-to-understand button names for settings such as color difference reference color settings and calibration, allowing smooth measurement and setting operations. ・High accuracy with instrumental error ΔE*ab within 0.6/CR-400, ΔE*ab within 0.8/CR-410, and repeatability ΔE*ab within 0.07. - You can measure with even higher accuracy by using the optional calibration function. (Set using data processor or optional accessory software) - You can set limit values ​​and make pass/fail judgments (pass/caution/fail display). (Set using data processor or optional accessory software) - In addition to the CR-300/310 color system, you can select from a wider variety of color systems. ・1,000 pieces of measurement data can be stored when using the measurement head alone, and 2,000 pieces of data can be stored when a data processor is connected. (The color difference reference color data is 100 data both when using the measurement head alone and when connected to the data processor) - Color difference graphs can also be displayed, allowing you to visually see the color difference status. (data processor) - Easy-to-understand text input method for mobile phones is used to input color difference reference color comments and calibration channel names. (data processor) -Large, easy-to-read LCD screen with backlight. ・You can select from 6 different languages ​​for the LCD display, including Japanese and English. ・It is highly economical as it can use rechargeable batteries. ■Main uses ・Painting field ・Rubber/plastic field ・Printing field ・Textile/dyeing field ・Food field ・Agriculture, forestry and fisheries fields ・Nitrogen industry field ・Housing field ・Medical/academic field ■Features ・Measurement possible with the measuring head alone ・Freely set any evaluation formula or color calculation formula ・A wide variety of accessories that can be used for various measurement objects ・Compact data processor with built-in high-speed printing printer ・Data compatible with CR-300/310.

  • Product

    Color difference meter CR series CR-400/410
  • Usage Scenarios

    Food Industry Use / Pharmaceutical & Medical Use / Architecture & Construction Use

Share this product


310+ people viewing

Last viewed: 8 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

2 Models of Color difference meter CR series CR-400/410

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Data processor Measurable number of times Data processor Observation light source Data processor Shortest measurable interval Data processor display range Data processor measurement time Measuring head Calibration channel Measuring head Color difference reference color Measuring head Illumination/light receiving optical system Measuring head Light receiving element Measuring head Measuring diameter/Illumination diameter Measuring head Measuring light source Measuring head Measuring time Measuring head Number of measurements possible Measuring head Number of stored data Measuring head Observation conditions Measuring head Observation light source Measuring head Operating temperature and humidity range Measuring head Others Measuring head Shortest measurable distance Measuring head Storage temperature and humidity range Measuring head display Measuring head display range Measuring head display section Measuring head instrumental error Measuring head language support Measuring head mass Measuring head pass/fail judgment Measuring head power supply Measuring head repeatability Measuring head size
Color difference meter CR series CR-400/410-Part Number-CR-400

CR-400

Available upon quote Approximately 800 times (when using batteries, according to our test conditions) C, D65 3 seconds Y: 0.01~160.00% (reflectance) 1 second 20 channels (ch00: for white calibration, ch01~19: for arbitrary calibration) 100 data Diffuse lighting vertical reception method (conforms to JIS Z 8722 geometric condition c/includes specular reflection light) Silicon photocell (6 pieces) Φ8/φ11 Pulsed xenon lamp 1 second Approximately 800 times (when using batteries, according to our test conditions) 1,000 data (measuring head and data processor store different contents) CIE2° visual field color matching function approximation: (x2 λ,yλ,zλ) C, D65 *Indicates that some parts of the measuring head alone do not function when the data processor is not connected, or when the data processor and the software that is sold separately are not configured. 0~40℃, relative humidity 85% or less (No condensation at 35℃) LCD backlight ON/OFF function (when ON: lights up for 30 seconds after operation key or measurement SW operation) 3 seconds -20~40℃, relative humidity 85% or less (No condensation at 35℃) Color value, color difference value, color difference graph, Pass/Caution/Fail display *Indicates that some parts of the measurement head alone do not function when the data processor is not connected, or when the data processor or the software that is sold separately is not configured. Y: 0.01~160.00% (reflectance) Dot matrix LCD with backlight (15 characters x 9 lines + 1 line of icon display) ΔE*ab: Within 0.6 BCRA Series II Average value of 12 colors LCD display (Japanese, English, German, French, Italian, Spanish) Approximately 540g (including 4 AAA batteries, excluding RS-232C cable and USB cable) Color difference limit value (box type/ellipse type limit) * Indicates that some parts of the measuring head alone do not function when a data processor is not connected, or when the data processor and software that is an optional accessory are not set. 4 AAA alkaline or NiMH batteries or dedicated AC adapter AC100V (50/60Hz) Standard deviation ΔE*ab within 0.07 (when measuring white calibration plate 30 times at 10 second intervals) 105 (W) × 217 (H) × 63 (D) mm
Color difference meter CR series CR-400/410-Part Number-CR-410

CR-410

Available upon quote Approximately 800 times (when using batteries, according to our test conditions) C, D65 3 seconds Y: 0.01~160.00% (reflectance) 1 second 20 channels (ch00: for white calibration, ch01~19: for arbitrary calibration) 100 data Large-area diffused lighting vertical reception method Silicon photocell (6 pieces) Φ50/φ53 Pulsed xenon lamp 1 second Approximately 800 times (when using batteries, according to our test conditions) 1,000 data (measuring head and data processor store different contents) CIE2° visual field color matching function approximation: (x2 λ,yλ,zλ) C, D65 *Indicates that some parts of the measuring head alone do not function when the data processor is not connected, or when the data processor and the software that is sold separately are not configured. 0~40℃, relative humidity 85% or less (No condensation at 35℃) LCD backlight ON/OFF function (when ON: lights up for 30 seconds after operation key or measurement SW operation) 3 seconds -20~40℃, relative humidity 85% or less (No condensation at 35℃) Color value, color difference value, color difference graph, Pass/Caution/Fail display *Indicates that some parts of the measurement head alone do not function when the data processor is not connected, or when the data processor or the software that is sold separately is not configured. Y: 0.01~160.00% (reflectance) Dot matrix LCD with backlight (15 characters x 9 lines + 1 line of icon display) ΔE*ab: Within 0.8 BCRA Series II Average value of 12 colors LCD display (Japanese, English, German, French, Italian, Spanish) Approx. 560g (including 4 AAA batteries, excluding RS-232C cable and USB cable) Color difference limit value (box type/ellipse type limit) * Indicates that some parts of the measuring head alone do not function when a data processor is not connected, or when the data processor and software that is an optional accessory are not set. 4 AAA alkaline or NiMH batteries or dedicated AC adapter AC100V (50/60Hz) Standard deviation ΔE*ab within 0.07 (when measuring white calibration plate 30 times at 10 second intervals) 105 (W) × 244 (H) × 63 (D) mm

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Konica Minolta Japan Co., Ltd.


View more products of Konica Minolta Japan Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree