All Categories
History
Product
Microinverter BDM 250-LVHandling Company
NORTHERN ELECTRIC AND POWER Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Remote island prevention protection | Weight | Overcurrent protection | Overvoltage/undervoltage protection | Overload protection | Reverse DC polarity protection | Permissible power grid voltage (Vac) | Permissible power grid frequency (Hz) | Current (rush) (peak and duration) | Maximum recommended PV power (Wp) | Maximum output overcurrent protection (Aac) | Maximum output fault current (Aac) | Maximum inverter backfeed current (Adc) | Maximum DC open circuit voltage (Vdc) | Maximum DC input current (Adc) | Dimensions (WHD) | Rated output current (Aac) | Rated AC output power (Wp) | Night tare loss (Wp) | Too much or too little frequency protection | Weighted average efficiency (CEC) | Power factor (cos phi, fixed) | Nominal power grid voltage (Vac) | Nominal frequency (Hz) | Degree of protection | Maximum number of units per branch (15A circuit) | THD | MPPT tracking accuracy | MPPT tracking range (Vdc) | Isc PV (Absolute Maximum) (Adc) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BDM 250-LV |
Available upon quote |
Yes |
2 km |
Yes |
Yes |
Yes |
Yes |
100-140* |
59.3a60.5* |
12A, 15us |
285 |
10 |
4.4A peak |
0 |
60 |
12 |
230*138*35 |
183 |
220 |
0.17 |
Yes |
95% |
>0.99 |
120 |
60 |
NEMA-6/IP-66/IP-67 |
8 |
<3% (at rated power) |
>99.5% |
22-55 |
14 |
Reviews shown here are reviews of companies.