All Categories

History

Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit-A50 R&D kit, 29° lens
Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit-Frier Systems Japan Co., Ltd.

Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit
Frier Systems Japan Co., Ltd.

Frier Systems Japan Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

161.7hours


About This Product

The FLIR A50/A70 Research and Development Kit is an affordable, ready-to-use solution for thermal image analysis in proof-of-concept electronics testing and R&D. By providing thousands of temperature measurement points, users can eliminate guesswork regarding heat content, reduce product development time, and increase product efficiency and reliability. These kits are the perfect choice for engineers and technicians who need a complete understanding of a system's thermal profile, or who require demonstrable thermal data to support critical decisions. Users can quickly view, record, analyze, and share thermal data using the included FLIR Research Studio software, or utilize industry standard connectivity to integrate into custom software applications as needed.

■Improve efficiency

A built-in visible camera with up to 640 x 480 (307,200 pixels) resolution, ±2°C temperature accuracy, and MSX® quickly reveals thermal properties, eliminates guesswork, and reduces product development time.

■Quickly obtain valid data

Start testing quickly with limited ramp-up time and a simple, non-proprietary, industry-standard interface. You can also perform qualitative and quantitative thermal analysis using the included FLIR Research Studio software.

■Sturdy, compact, flexible

Easily install IP66 rated cameras with M-style connectors in any location. Move from design and test steps to process control using GigEVision and GenICam protocols.

  • Product

    Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit

Share this product


250+ people viewing

Last viewed: 5 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Communication and data storage Ethernet connector type Communication and data storage WiFi Infrared resolution Focus Measurement analysis accuracy Measurement analysis Standard temperature range Temperature resolution_NETD Standard temperature range Detector spacing Detector type Frame rate Digital data streaming on your computer Dynamic range Spectral range Imaging and lenses Infrared resolution Imaging and lenses Field of view (FOV) Imaging and lenses Image modes Imaging and Lens Focus Imaging and Lens Temperature Resolution_NETD Imaging and Lens Detector Spacing Imaging and Lens Detector Type Imaging and lenses Minimum focal length Imaging and Lenses Visible Camera Imaging and Lenses Available Lenses Imaging and lenses Lens identification Imaging and Lenses Lenses Imaging and Lens Macro Mode Imaging and lens frame rate Imaging and Lens Dynamic Range Imaging and lens spectral range
Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit-Part Number-A50 R&D kit, 29° lens

A50 R&D kit, 29° lens

Available upon quote

M12 8-pin X-code, female

Yes, female RP-SMA connector, peer-to-peer (ad hoc) or infrastructure (network)

464 × 348

Adjustable with included focus tool

±2℃ or ±2℃ error (relative to reading) at ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher

-20℃~175℃, 175℃~1,000℃

50 mK or less

-20℃~175℃, 175℃~1,000℃

17 µm

Uncooled microbolometer

30Hz

Via a workstation running the included ResearchStudio software

16 bit

7.5 – 14.0 µm

464 × 348

29°×22°

Thermal, visible light, MSX®, FSX®

Adjustable with included focus tool

50 mK or less

17 µm

Uncooled microbolometer

0.25 m

Included, 1,280 x 960 resolution

Fixed lens only

None

29° fixed

No

30Hz

16 bit

7.5 – 14.0 µm

Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit-Part Number-A50 R&D kit, 51° lens

A50 R&D kit, 51° lens

Available upon quote

M12 8-pin X-code, female

Yes, female RP-SMA connector, peer-to-peer (ad hoc) or infrastructure (network)

464 × 348

Adjustable with included focus tool

±2℃ or ±2℃ error (relative to reading) at ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher

-20℃~175℃, 175℃~1,000℃

50 mK or less

-20℃~175℃, 175℃~1,000℃

17 µm

Uncooled microbolometer

30Hz

Via a workstation running the included ResearchStudio software

16 bit

7.5 – 14.0 µm

464 × 348

51° × 39°

Thermal, visible light, MSX®, FSX®

Adjustable with included focus tool

50 mK or less

17 µm

Uncooled microbolometer

0.2 m

Included, 1,280 x 960 resolution

Fixed lens only

None

Fixed at 51°

No

30Hz

16 bit

7.5 – 14.0 µm

Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit-Part Number-A50 R&D kit, 95° lens

A50 R&D kit, 95° lens

Available upon quote

M12 8-pin X-code, female

Yes, female RP-SMA connector, peer-to-peer (ad hoc) or infrastructure (network)

464 × 348

Adjustable with included focus tool

±2℃ or ±2℃ error (relative to reading) at ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher

-20℃~175℃, 175℃~1,000℃

50 mK or less

-20℃~175℃, 175℃~1,000℃

17 µm

Uncooled microbolometer

30Hz

Via a workstation running the included ResearchStudio software

16 bit

7.5 – 14.0 µm

464 × 348

51° × 39°

Thermal, visible light, MSX®, FSX®

Adjustable with included focus tool

50 mK or less

17 µm

Uncooled microbolometer

0.1 m

Included, 1,280 x 960 resolution

Fixed lens only

None

Fixed at 51°

No

30Hz

16 bit

7.5 – 14.0 µm

Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit-Part Number-A70 R&D kit, 29° lens

A70 R&D kit, 29° lens

Available upon quote

M12 8-pin X-code, female

Yes, female RP-SMA connector, peer-to-peer (ad hoc) or infrastructure (network)

640×480

Adjustable with included focus tool

±2℃ or ±2℃ error (relative to reading) at ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher

-20℃~175℃, -20℃~250℃, 175℃~1,000℃

50 mK or less

-20℃~175℃, -20℃~250℃, 175℃~1,000℃

17 µm

Uncooled microbolometer

30Hz

Via a workstation running the included ResearchStudio software

16 bit

7.5 – 14.0 µm

640×480

29°×22°

Thermal, visible light, MSX®, FSX®

Adjustable with included focus tool

50 mK or less

17 µm

Uncooled microbolometer

0.25 m

Included, 1,280 x 960 resolution

Fixed lens only

None

29° fixed

No

30Hz

16 bit

7.5 – 14.0 µm

Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit-Part Number-A70 R&D kit, 51° lens

A70 R&D kit, 51° lens

Available upon quote

M12 8-pin X-code, female

Yes, female RP-SMA connector, peer-to-peer (ad hoc) or infrastructure (network)

640×480

Adjustable with included focus tool

±2℃ or ±2℃ error (relative to reading) at ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher

-20℃~175℃, -20℃~250℃, 175℃~1,000℃

50 mK or less

-20℃~175℃, -20℃~250℃, 175℃~1,000℃

17 µm

Uncooled microbolometer

30Hz

Via a workstation running the included ResearchStudio software

16 bit

7.5 – 14.0 µm

640×480

51° × 39°

Thermal, visible light, MSX®, FSX®

Adjustable with included focus tool

50 mK or less

17 µm

Uncooled microbolometer

0.2 m

Included, 1,280 x 960 resolution

Fixed lens only

None

Fixed at 51°

No

30Hz

16 bit

7.5 – 14.0 µm

Fixed Infrared Thermography Camera FLIR A50/A70 Research and Development Kit-Part Number-A70 R&D kit, 95° lens

A70 R&D kit, 95° lens

Available upon quote

M12 8-pin X-code, female

Yes, female RP-SMA connector, peer-to-peer (ad hoc) or infrastructure (network)

640×480

Adjustable with included focus tool

±2℃ or ±2℃ error (relative to reading) at ambient temperature 15℃~35℃ and measurement target temperature 0℃ or higher

-20℃~175℃, -20℃~250℃, 175℃~1,000℃

50 mK or less

-20℃~175℃, -20℃~250℃, 175℃~1,000℃

17 µm

Uncooled microbolometer

30Hz

Via a workstation running the included ResearchStudio software

16 bit

7.5 – 14.0 µm

640×480

51° × 39°

Thermal, visible light, MSX®, FSX®

Adjustable with included focus tool

50 mK or less

17 µm

Uncooled microbolometer

0.1 m

Included, 1,280 x 960 resolution

Fixed lens only

None

Fixed at 51°

No

30Hz

16 bit

7.5 – 14.0 µm

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Industrial Cameras Products

Other products of Frier Systems Japan Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Frier Systems Japan Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

161.7hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.