Product Image | Part Number | Price (excluding tax) | Analog output 1 | Analog output 2 | Averaging time | Contact output 1 | Contact output 2 | Contact output 3 | Contact output 4 | Dedicated cable | Digital output | Flow velocity resolution | Gas seal adapter | Gas seal unit | Installation conditions | Large size for general gas (flange type) | Lightning protection | Measurement accuracy | Measurement compensation range | Measurement method | Number of survey lines | Operating temperature range | Power consumption | Power supply | Pressure | Probe fittings | Reproducibility | Standard type for general gas (screw type) | Survey line method | Temperature | Temperature/pressure power supply | Ultrasonic thermometer |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GF-2500 |
Available upon quote |
Various flow rate outputs Range: DC4~20mA isolated output Over range: DC0~24mA Load resistance: 1,000Ω or less |
Various flow outputs, backflow outputs, temperature outputs, pressure outputs Range: DC4~20mA isolated output Over range: DC0~24mA Load resistance: 1,000Ω or less |
Standard 10 seconds (can be set arbitrarily from 0.5 to 180 seconds) |
Integrated pulse output Open collector: Rated 30V, 0.2A Pulse width: 2 types selection: 1.6ms and 50ms |
Accumulated pulse output, alarm output, forward/reverse judgment output, upper limit output, lower limit output Open collector: Rated 30V, 0.2A |
Alarm output, forward/reverse judgment output, upper limit output, lower limit output Open collector: Rated 30V, 0.2A |
Alarm output, forward/reverse judgment output, upper limit output, lower limit output Open collector: Rated 30V, 0.2A |
Standard length between detector and converter: 6m or 10m | RS422×1 | 0.5mm/sec or less | When gas seal unit is not required | General use, large size use, special use use | Straight pipe section: 15D or more on the upstream side, 5D or more on the downstream side |
Nominal diameter: 500mm~ Temperature: -30~180℃ Pressure: -0.05~1MPa (-0.5~10kgf/cm2) |
Built-in surge absorber | ±1.0%FS (flow velocity 5~60m/s) | Design temperature ±25℃, design pressure ±30% | Ultrasonic pulse propagation time reciprocal difference calculation method | 1 or 2 lines (optional) | -10~+50℃ | Max.25 (W) | AC100V ±10%, 50/60Hz Optional AC115V, 220V | DC4~20mA | Combined with gas seal unit | ±0.2% |
Nominal diameter: 50mm~500mm Temperature: -30~180℃ Pressure: -0.05~1MPa (-0.5~10kgf/cm2) |
Z or V method | DC4~20mA | Output rating: DC24±0.5V 0.2A | Temperature measurement using ultrasonic pulse propagation time (air) |