High-performance multifunctional vector inverter VF-TSS seriesHandling Company
Daido Japan Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply (V,Hz) | Weight (kg) | Applicable motor capacity (kW) Heavy load | Applicable motor capacity (kW) Standard load | Box size code | Rated overload current (A) Heavy load | Rated overload current (A) Standard load | Rated output current (A) Heavy load | Rated output current (A) Standard load | Rated output voltage (V) | Rated output capacity (kVA) Heavy load | Rated output capacity (kVA) Standard load | Design compliant with safety regulations | Output frequency range (Hz) | Cooling method | Input current (A) Heavy load | Input current (A) Standard load | Protective structure | AC power fluctuation range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VF-TSS-20040B |
Available upon quote |
Three phase 200~240V 50/60Hz |
1.8 |
0.4 |
0.75 |
Three-phase 220V series |
150%/1 minute |
120%/1 minute |
3 |
4.2 |
Three-phase 200~240V (corresponds to input voltage) |
1.1 |
1.6 |
UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 |
0.1~600.00Hz |
Natural cooling |
4 |
5 |
IP20 |
170~264V 50/60Hz / ±5% |
|
VF-TSS-20075B |
Available upon quote |
Three phase 200~240V 50/60Hz |
1.8 |
0.75 |
1.5 |
Three-phase 220V series |
150%/1 minute |
120%/1 minute |
5 |
6.8 |
Three-phase 200~240V (corresponds to input voltage) |
1.9 |
2.6 |
UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 |
0.1~600.00Hz |
Natural cooling |
6 |
8 |
IP20 |
170~264V 50/60Hz / ±5% |
|
VF-TSS-20150B |
Available upon quote |
Three phase 200~240V 50/60Hz |
1.9 |
1.5 |
2.2 |
Three-phase 220V series |
150%/1 minute |
120%/1 minute |
8 |
10 |
Three-phase 200~240V (corresponds to input voltage) |
3 |
3.8 |
UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 |
0.1~600.00Hz |
Forced air cooling |
10 |
12 |
IP20 |
170~264V 50/60Hz / ±5% |
|
VF-TSS-20220B |
Available upon quote |
Three phase 200~240V 50/60Hz |
2 |
2.2 |
3.7 |
Three-phase 220V series |
150%/1 minute |
120%/1 minute |
11 |
15.2 |
Three-phase 200~240V (corresponds to input voltage) |
4.2 |
5.8 |
UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 |
0.1~600.00Hz |
Forced air cooling |
14 |
18 |
IP20 |
170~264V 50/60Hz / ±5% |
|
VF-TSS-20370B |
Available upon quote |
Three phase 200~240V 50/60Hz |
2.1 |
3.7 |
5.5 |
Three-phase 220V series |
150%/1 minute |
120%/1 minute |
17 |
Twenty one |
Three-phase 200~240V (corresponds to input voltage) |
6.5 |
8 |
UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 |
0.1~600.00Hz |
Forced air cooling |
18 |
Twenty five |
IP20 |
170~264V 50/60Hz / ±5% |
|
VF-TSS-40040B |
Available upon quote |
Three phase 380~480V 50/60Hz |
1.8 |
0.4 |
0.75 |
Three-phase 400V series |
150%/1 minute |
120%/1 minute |
1.5 |
2.4 |
Three-phase 380~480V (corresponds to input voltage) |
1.1 |
1.8 |
UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 |
0.1~600.00Hz |
Natural cooling |
2 |
2.8 |
IP20 |
323~528V 50/60Hz / ±5% |
|
VF-TSS-40075B |
Available upon quote |
Three phase 380~480V 50/60Hz |
1.8 |
0.75 |
1.5 |
Three-phase 400V series |
150%/1 minute |
120%/1 minute |
2.5 |
3.5 |
Three-phase 380~480V (corresponds to input voltage) |
1.9 |
2.7 |
UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 |
0.1~600.00Hz |
Natural cooling |
3.5 |
4.2 |
IP20 |
323~528V 50/60Hz / ±5% |
|
VF-TSS-40150B |
Available upon quote |
Three phase 380~480V 50/60Hz |
1.9 |
1.5 |
2.2 |
Three-phase 400V series |
150%/1 minute |
120%/1 minute |
4 |
4.8 |
Three-phase 380~480V (corresponds to input voltage) |
3 |
3.7 |
UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 |
0.1~600.00Hz |
Forced air cooling |
5 |
5.8 |
IP20 |
323~528V 50/60Hz / ±5% |
|
VF-TSS-40220B |
Available upon quote |
Three phase 380~480V 50/60Hz |
2 |
2.2 |
3.7 |
Three-phase 400V series |
150%/1 minute |
120%/1 minute |
6 |
9 |
Three-phase 380~480V (corresponds to input voltage) |
4.6 |
6.9 |
UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 |
0.1~600.00Hz |
Forced air cooling |
8 |
12 |
IP20 |
323~528V 50/60Hz / ±5% |
|
VF-TSS-40370B |
Available upon quote |
Three phase 380~480V 50/60Hz |
2 |
3.7 |
5.5 |
Three-phase 400V series |
150%/1 minute |
120%/1 minute |
9 |
11 |
Three-phase 380~480V (corresponds to input voltage) |
6.9 |
8.4 |
UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 |
0.1~600.00Hz |
Forced air cooling |
12 |
13 |
IP20 |
323~528V 50/60Hz / ±5% |